Objectives: Veno-arterial extracorporeal membrane oxygenation (VA ECMO) has been increasingly used in cardiopulmonary resuscitation (ECPR) in select patients. Few centers have published their experience or outcomes with ECPR. The aim of our study was to evaluate outcomes of adult patients in cardiac arrest placed on VA ECMO in the catheterization laboratory.
View Article and Find Full Text PDFSedatives and analgesics are frequently used in critically ill adult patients requiring mechanical ventilation in the intensive care unit, but optimal agent selection and dosing in patients supported with venoarterial extracorporeal membrane oxygenation remain poorly defined. This retrospective study evaluated whether sedative and analgesic agent selection and dosing had any impact on clinical outcomes after venoarterial extracorporeal membrane oxygenation decannulation. The primary endpoint of our study was the incidence of delirium within 48 h after venoarterial extracorporeal membrane oxygenation decannulation in patients who received an empiric ⩾50% sedation reduction of benzodiazepines (N = 22, group 2) compared to those who did not (N = 10, group 1) and those who required no sedatives within 24 h prior to venoarterial extracorporeal membrane oxygenation decannulation (N = 21, group 3).
View Article and Find Full Text PDFBackground: The use of cardiac computed tomography (CT) for quantification of ventricular function is limited by relatively high radiation dose.
Objectives: The goal of this study was to describe the radiation exposure and image quality of 70 kVp functional cardiac CT in patients with congenital heart disease (CHD).
Methods: A retrospective review of 70 kVp ECG gated functional CT scans using tube current modulation was performed in CHD patients at a single institution.
Background: Vascular endothelial dysfunction may play an important role in the progression of heart failure (HF). We hypothesize that elevated levels of vascular markers, placental-like growth factor, and soluble Fms-like tyrosine kinase-1 (sFlt-1) are associated with adverse outcomes in patients with HF. We also assessed possible triggers of sFlt-1 elevation in animal HF models.
View Article and Find Full Text PDFEndomyocardial biopsy (EMB) is central to the diagnosis of giant-cell myocarditis (GCM) and planning further management. There is, however, no guideline-directed recommendation on re-biopsy or left ventricular EMB in a suspected case of acute, fulminant myocarditis following an indeterminate first biopsy. This manuscript illustrates, with a case, the changing role for EMB in the current era in the diagnosis of GCM.
View Article and Find Full Text PDFNat Rev Cardiol
October 2013
Cardiac contractility modulation (CCM) is the application of nonexcitatory electrical signals to the myocardium, during the absolute refractory period of the action potential, to elicit a positive inotropic effect without increasing myocardial oxygen consumption. These effects are independent of QRS duration; consequently, CCM device therapy might benefit symptomatic patients with reduced left ventricular ejection fraction who are not candidates for cardiac resynchronization therapy. Preclinical studies have demonstrated a rapid positive inotropic effect of CCM, which seems to be mediated by modulation of cardiomyocyte Ca(2+) fluxes and alterations in the phosphorylation of cardiac phospholamban.
View Article and Find Full Text PDFAcute heart failure syndromes (AHFS) represent the most common discharge diagnoses in adults over age 65 and translate into dramatically increased heart failure-associated morbidity and mortality. Conventional approaches to the early detection of pulmonary and systemic congestion have been shown to be of limited sensitivity. Despite their proven efficacy, disease management and structured telephone support programs have failed to achieve widespread use in part due to their resource intensiveness and reliance upon motivated patients.
View Article and Find Full Text PDFA microfluidic device has been developed that can adsorb proteins from solution, hold them with negligible denaturation, and release them on command. The active element in the device is a 4-nanometer-thick polymer film that can be thermally switched between an antifouling hydrophilic state and a protein-adsorbing state that is more hydrophobic. This active polymer has been integrated into a microfluidic hot plate that can be programmed to adsorb and desorb protein monolayers in less than 1 second.
View Article and Find Full Text PDF