Background: In this study we present the Tracking Accessory 3 (TA3) as an alternative to the commercial gating block (GB) surrogate for the Varian Truebeam™ gating system (TGS). The TGS requires three visible reflectors to track the surrogate, presenting an opportunity for a surrogate to be made with less material and thus smaller dosimetric footprint than the commercial four reflector model.
Materials And Methods: Relative dose and depth dose profiles below the TA3 and the GB were measured with radiosensitive film.
Study of skin penetration and distribution of the drug compounds in the skin is a major challenge in the development of topical drug products for treatment of skin diseases. It is crucial to have fast and efficacious screening methods which can provide information concerning the skin penetration and the distribution of the drug molecules in the region of the target. Mass spectrometry imaging (MSI) such as matrix-assisted laser desorption/ionization (MALDI)-MSI offers the opportunity to analyze the drug distribution at micrometer scale, but is a low throughput technique.
View Article and Find Full Text PDFFocal cerebral ischaemia has an initial phase of inflammation and tissue injury followed by a later phase of resolution and repair. Mass spectrometry imaging (desorption electrospray ionization and matrix assisted laser desorption ionization) was applied on brain sections from mice 2 h, 24 h, 5d, 7d, and 20d after permanent focal cerebral ischaemia. Within 24 h, N-acyl-phosphatidylethanolamines, lysophosphatidylcholine, and ceramide accumulated, while sphingomyelin disappeared.
View Article and Find Full Text PDFBackground: Topical 5-Fluorouracil (5-FU) exhibits suboptimal efficacy for non-melanoma skin cancer, attributed to insufficient intracutaneous penetration. This study investigates the impact of ablative fractional laser (AFXL) at different laser-channel depths on cutaneous 5-FU pharmacokinetics and biodistribution.
Methods: In vitro porcine skin underwent AFXL-exposure using a fractional 10,600 nm CO-laser, generating microscopic ablation zones (MAZ) reaching the dermoepidermal junction (MAZ-ED), superficial-(MAZ-DS), or mid-dermis(MAZ-DM).
Imaging ellipsometry (IE) has been applied to generate laterally resolved thickness maps of spin-coated membranes in both the dry and fully hydrated state. Spin-coating offers a convenient preparation method for stacked supported membranes, and in-depth thickness maps for such films can be measured by IE, thereby going beyond topography measurements of the top surface. We find that dry lipid films of POPC (1-palmitoyl-2-oleoyl-sn-glycero-3-phosphocholine) have a highly ordered multilamellar structure which allows counting of the number of individual bilayers in a thick film from the progression in a concentration series.
View Article and Find Full Text PDF