Objectives: Impaired image quality and long scan times frequently occur in respiratory-triggered sequences in liver magnetic resonance imaging (MRI). We evaluated the impact of an in-bore active breathing guidance (BG) application on image quality and scan time of respiratory-triggered T2-weighted (T2) and diffusion-weighted imaging (DWI) by comparing sequences with standard triggering (T2S and DWIS) and with BG (T2BG and DWIBG).
Materials And Methods: In this prospective study, random patients with clinical indications for liver MRI underwent 3 T MRI with standard and BG acquisitions.
Rationale And Objectives: To assess the performance of an industry-developed deep learning (DL) algorithm to reconstruct low-resolution Cartesian T1-weighted dynamic contrast-enhanced (T1w) and T2-weighted turbo-spin-echo (T2w) sequences and compare them to standard sequences.
Materials And Methods: Female patients with indications for breast MRI were included in this prospective study. The study protocol at 1.
Objectives: The aim of this study was to assess the impact of an iterative metal artifact reduction (iMAR) algorithm combined with virtual monoenergetic images (VMIs) for artifact reduction in photon-counting detector computed tomography (PCDCT) during interventions.
Materials And Methods: Using an abdominal phantom, we conducted evaluations on the efficacy of iMAR and VMIs for mitigating image artifacts during interventions on a PCDCT. Four different puncture devices were employed under 2 scan modes (QuantumSn at 100 kV, Quantumplus at 140 kV) to simulate various clinical scenarios.
Objectives: To implement and evaluate a super-fast and high-quality biparametric MRI (bpMRI) protocol for prostate imaging acquired at a new ultra-high gradient 3.0-T MRI system.
Methods: Participants with clinically suspected prostate cancer prospectively underwent a multiparametric MRI (mpMRI) on a new 3.
Objectives: To compare standard-resolution balanced steady-state free precession (bSSFP) cine images with cine images acquired at low resolution but reconstructed with a deep learning (DL) super-resolution algorithm.
Materials And Methods: Cine cardiovascular magnetic resonance (CMR) datasets (short-axis and 4-chamber views) were prospectively acquired in healthy volunteers and patients at normal (cine: 1.89 × 1.
Objectives: To assess the prognostic value of cardiac MRI (CMR) parameters for the occurrence of major adverse cardiac events (MACE) in patients with infarct-like myocarditis.
Methods: In this retrospective single-center study, patients with CMR-confirmed acute myocarditis with infarct-like presentation were identified (2007-2020). Functional and structural parameters were analyzed including late gadolinium enhancement (LGE).
Aims: To evaluate different cardiovascular magnetic resonance (CMR) parameters for the differentiation of light chain amyloidosis (AL) and transthyretin-related amyloidosis (ATTR).
Methods And Results: In total, 75 patients, 53 with cardiac amyloidosis {20 patients with AL [66 ± 12 years, 14 males (70%)] and 33 patients with ATTR [78 ± 5 years, 28 males (88%)]} were retrospectively analysed regarding CMR parameters such as T1 and T2 mapping, extracellular volume (ECV), late gadolinium enhancement (LGE) distribution patterns, and myocardial strain, and compared to a control cohort with other causes of left ventricular hypertrophy {LVH; 22 patients [53 ± 16 years, 17 males (85%)]}. One-way ANOVA and receiver operating characteristic analysis were used for statistical analysis.
Rationale And Objectives: Aim of this study was to assess the impact of contrast media dose (CMD) reduction on diagnostic quality of photon-counting detector CT (PCD-CT) and energy-integrating detector CT (EID-CT).
Methods: CT scans of the abdominal region with differing CMD acquired in portal venous phase on a PCD-CT were included and compared to EID-CT scans. Diagnostic quality and contrast intensity were rated.
Background: Patients are increasingly using Generative Pre-trained Transformer 4 (GPT-4) to better understand their own radiology findings.
Purpose: To evaluate the performance of GPT-4 in transforming cardiovascular magnetic resonance (CMR) reports into text that is comprehensible to medical laypersons.
Methods: ChatGPT with GPT-4 architecture was used to generate three different explained versions of 20 various CMR reports (n = 60) using the same prompt: "Explain the radiology report in a language understandable to a medical layperson".
Aim of this study was to assess the impact of virtual monoenergetic images (VMI) on dental implant artifacts in photon-counting detector computed tomography (PCD-CT) compared to standard reconstructed polychromatic images (PI). 30 scans with extensive (≥ 5 dental implants) dental implant-associated artifacts were retrospectively analyzed. Scans were acquired during clinical routine on a PCD-CT.
View Article and Find Full Text PDFAim of this study was to assess the impact of virtual monoenergetic images (VMI) in combination and comparison with iterative metal artifact reduction (IMAR) on hip prosthesis-associated artifacts in photon-counting detector CT (PCD-CT). Retrospectively, 33 scans with hip prosthesis-associated artifacts acquired during clinical routine on a PCD-CT between 08/2022 and 09/2022 were analyzed. VMI were reconstructed for 100-190 keV with and without IMAR, and compared to polychromatic images.
View Article and Find Full Text PDFBackground The objective of this study was to investigate cardiac abnormalities in intensive care unit (ICU) survivors of critical illness and to determine whether temporary acute kidney injury (AKI) is associated with more pronounced findings on cardiovascular magnetic resonance. Methods and Results There were 2175 patients treated in the ICU (from 2015 until 2021) due to critical illness who were screened for study eligibility. Post-ICU patients without known cardiac disease were prospectively recruited from March 2021 to May 2022.
View Article and Find Full Text PDFPurpose: To compare standard breath-hold (BH) cine imaging to a radial pseudo-golden-angle free-breathing (FB) technique in congenital heart disease (CHD).
Methods: In this prospective study, short-axis and 4-chamber BH and FB cardiac MRI sequences of 25 participants with CHD acquired at 1.5 Tesla, were quantitatively compared regarding ventricular volumes, function, interventricular septum thickness (IVSD), apparent signal to noise ratio (aSNR), and estimated contrast to noise ratio (eCNR).
Objectives: To find simple imaging-based features on cardiac magnetic resonance (CMR) that are associated with major adverse cardiovascular events (MACE) in takotsubo syndrome (TTS).
Methods: Patients with TTS referred for CMR between 2007 and 2021 were retrospectively evaluated. Besides standard CMR analysis, commonly known complications of TTS based on expert knowledge were assessed and summarised via a newly developed PERT score (one point each for pleural effusion, pericardial effusion, right ventricular involvement, and ventricular thrombus).
Background: Outcome assessment in stroke patients is essential for evidence-based stroke care planning. Computed tomography (CT) is the mainstay of diagnosis in acute stroke. This study aimed to investigate whether CT-derived cervical fat-free muscle fraction (FFMF) as a biomarker of muscle quality is associated with outcome parameters after acute ischemic stroke.
View Article and Find Full Text PDFPurpose: To investigate and compare the physical properties of the new generation Gore VIATORR-Controlled Expansion Endoprosthesis (VCX) to those of the predecessor VIATORR stent in an in vitro experimental setup.
Materials And Methods: A total of 12 stents (8 VCX; 4 VIATORR; GORE, USA) were examined. Radial resistive force (RRF) and chronic outward force (COF) were assessed using a radial force testing machine (RX-650, Machine Solutions Inc.
Background: Mass COVID-19 vaccination campaigns have helped impede the COVID-19 pandemic. In rare cases, some vaccines have led to vaccine associated myocarditis in a specific subset of the population, usually young males. Cardiac magnetic resonance (CMR) can reliably diagnose vaccine associated myocarditis, but follow-up data of CMR proven acute myocarditis is scarce.
View Article and Find Full Text PDFAims: The exact role of portal hypertension in cirrhotic cardiomyopathy remains unclear, and it is uncertain whether cardiac abnormalities also occur in non-cirrhotic portal hypertension (NCPH). This magnetic resonance imaging (MRI) study aimed to evaluate the presence of subclinical myocardial dysfunction, oedema, and fibrosis in NCPH.
Methods And Results: In this prospective study (2018-2022), participants underwent multiparametric abdominal and cardiac MRI including assessment of cardiac function, myocardial oedema, late gadolinium enhancement (LGE), and abdominal and cardiac mapping [T1 and T2 relaxation times, extracellular volume fraction (ECV)].
J Cardiovasc Magn Reson
November 2022
Background: To evaluate the great vessels in young children with complex congenital heart disease (CHD) using non-contrast cardiovascular magnetic resonance angiography (CMRA) based on three-dimensional relaxation-enhanced angiography without contrast (REACT) in comparison to contrast-enhanced steady-state CMRA.
Methods: In this retrospective study from April to July 2021, respiratory- and electrocardiogram-gated native REACT CMRA was compared to contrast-enhanced single-phase steady-state CMRA in children with CHD who underwent CMRA at 3T under deep sedation. Vascular assessment included image quality (1 = non-diagnostic, 5 = excellent), vessel diameter, and diagnostic findings.
Objectives: The aim of this study was to compare a new compressed sensing (CS) method for T2-weighted propeller acquisitions (T2 CS ) with conventional T2-weighted propeller sequences (T2 conv ) in terms of achieving a higher image quality, while reducing the acquisition time.
Materials And Methods: Male participants with a clinical suspicion of prostate cancer were prospectively enrolled and underwent prostate magnetic resonance imaging at 3 T. Axial and sagittal images of the T2 conv sequence and the T2 CS sequence were acquired.
Radiol Cardiothorac Imaging
June 2022
Purpose: To evaluate the diagnostic performance of layer-specific cardiac MRI feature-tracking (FT) strain analysis in patients with acute myocarditis.
Materials And Methods: Seventy patients (mean age, 43 years ± 19 [SD]; 46 men) with clinically defined acute myocarditis and 42 healthy controls who underwent cardiac MRI from March 2014 to November 2018 were retrospectively analyzed. FT-based left ventricular peak systolic global longitudinal strain (GLS) and global circumferential strain (GCS) were assessed at subendocardial, midmyocardial, and subepicardial layers.
To explore the image quality and radiation dose of dual source high-pitch cardiac computed tomography with tailored contrast injection protocols for pediatric congenital heart disease patients (CHD). In total, 27 infants with CHD (median age 109 days [IQR 6-199]) were retrospectively analyzed regarding dose length product (DLP) and effective dose (ED) after undergoing cardiothoracic CT imaging. Scan parameters were adjusted on a dual source/detector CT (DSCT) to minimize radiation dose while maintaining adequate quality.
View Article and Find Full Text PDFWe aimed to investigate the diagnostic utility of MRI extracellular volume fraction (ECV) for the assessment of liver cirrhosis severity as defined by Child-Pugh class. In this retrospective study, 90 patients (68 cirrhotic patients and 22 controls), who underwent multiparametric liver MRI, were identified. Hepatic T1 relaxation times and ECV were assessed.
View Article and Find Full Text PDFAlthough CT and MRI are standard procedures in cirrhosis diagnosis, differentiation of etiology based on imaging is not established. This proof-of-concept study explores the potential of deep learning (DL) to support imaging-based differentiation of the etiology of liver cirrhosis. This retrospective, monocentric study included 465 patients with confirmed diagnosis of (a) alcoholic (n = 221) and (b) other-than-alcoholic (n = 244) cirrhosis.
View Article and Find Full Text PDFPurpose: To evaluate cardiac MRI characteristics in patients with suspected hypersensitivity myocarditis following mRNA COVID-19 vaccination.
Materials And Methods: Patients clinically suspected of acute myocarditis after COVID-19 vaccination were retrospectively analyzed and compared against a healthy control group. Cardiac MRI protocol included parameters such as T1 and T2 relaxation times, extracellular volume (ECV), T2 signal intensity ratio, and late gadolinium enhancement (LGE).