To evaluate the ability of the Gosset icterometer to identify the need for serum bilirubin measurement in premature infants we compared 269 icterometer readings with simultaneous serum bilirubin determinations in 90 premature infants of < 37 completed weeks of gestation. The relationship between serum bilirubin and icterometer values was different from that described in term infants. Mean serum bilirubin concentrations were lower at each icterometer level in premature infants than those reported in term babies.
View Article and Find Full Text PDFFive healthy adult mares and 1 gelding were given a single dose (15 mg/kg of body weight) of metronidazole per rectum. After manual evacuation of feces from the rectum, a suspension of crushed tablets and water (40 ml) was administered via a 28-F catheter advanced 30 cm into the rectum. Blood samples were obtained by jugular venipuncture, and metronidazole concentration was measured serially for the 14 hours after drug administration.
View Article and Find Full Text PDFJ Orthop Res
November 1993
Titanium and titanium-6% aluminum-4% vanadium (Ti-6Al-4V) are known to be biocompatible and corrosion resistant. However, there have been numerous reports of elevated tissue levels of titanium due to passive dissolution, wear, or fretting corrosion of implants. Studies were undertaken to determine whether the fretting corrosion of Ti-6Al-4V could be reduced by surface treatment of one or both surfaces in a fretting situation.
View Article and Find Full Text PDFJ Dev Behav Pediatr
October 1993
Case identification indexes based on the mother-completed Missouri Children's Behavior Checklist (MCBC) were compared with pediatrician identification of behavioral and emotional problems in 41 children seen for well-child examinations. Case identification indexes also were examined as a function of child gender and age and maternal education. The criterion was presence of DSM-III diagnoses determined through Child Assessment Schedule interviews of child or mother.
View Article and Find Full Text PDFCorrosion of porous coated cobalt chromium specimens surgically implanted subcutaneously in hamsters was accelerated by application of a fixed anodic potential. Corrosion current measurements were utilized for prediction of metal ion release based on Faraday's law. Daily urine samples were collected pre- and post-stimulation, and, at animal sacrifice, organs and blood samples were taken for chemical analysis.
View Article and Find Full Text PDFJ Child Psychol Psychiatry
July 1993
This study replicated with nonreferred children the finding with psychiatrically referred children that mother-child concordance was a function of symptom type. Low mother-child concordance for internalizing problems and moderate concordance for externalizing problems characteristic of psychiatric samples was found to generalize to nonreferred children. Furthermore, mother-child concordance was also found to be a function of child gender and age.
View Article and Find Full Text PDFEach of 5 healthy mares was given 5 consecutive IM injections of ceftiofur sodium (2 mg/kg of body weight; 50 mg/ml) at 12-hour intervals. Ceftiofur concentrations were measured serially in serum, synovial fluid, peritoneal fluid, and urine, and were measured in CSF and endometrial tissue after the fifth dose. Mean elimination rate constant was 0.
View Article and Find Full Text PDFThis study provides validity information about the Missouri Children's Behavior Checklist (MCBC) classifications system with nonreferred children. MCBC behavior patterns of 41 children were related to DSM-III symptomatology ascertained through a structured clinical interview, the Child Assessment Schedule, conducted with the mother. The findings indicated that considering the Undifferentiated Disturbance pattern as an indicator of poor adjustment may be unwarranted with nonreferred children.
View Article and Find Full Text PDFJ Biomed Mater Res
November 1992
Hamsters were injected with titanium, aluminum, and vanadium salts either intraperitoneally or intramuscularly to study the transport, storage, and elimination of these metals. Blood samples were taken at 4 h or 24 h, and urine samples were taken at 24, 48, and 72 h. The hamsters were then injected weekly for 5 weeks after the initial injection.
View Article and Find Full Text PDFSix healthy adult mixed breed dogs were each given 5 oral doses of trimethoprim (TMP)/sulfadiazine (SDZ) at 2 dosage regimens: 5 mg of TMP/kg of body weight and 25 mg of SDZ/kg every 24 hours (experiment 1) and every 12 hours (experiment 2). Serum and skin concentrations of each drug were measured serially throughout each experiment and mean serum concentrations of TMP and SDZ were determined for each drug for 24 hours (experiment 1) and 12 hours (experiment 2) after the last dose was given. In experiment 1, mean serum TMP concentration was 0.
View Article and Find Full Text PDFAlthough infection is a serious complication associated with the use of orthopedic prosthetic implants, the impact of the metal used in these devices on host defense is poorly understood. The authors investigated the effect of stainless steel, titanium, titanium alloy, and cobalt-chromium alloy on the respiratory burst of polymorphonuclear leukocytes (PMN), a vital component of bactericidal activity. In the presence of stainless steel powder or supernatants obtained from the incubation of stainless steel in buffer, superoxide production by PMN was significantly impaired.
View Article and Find Full Text PDFPharmacokinetic values for flunixin meglumine (1 mg/kg of body weight) and phenylbutazone (4 mg/kg) dosages were determined after a single IV injection with and without concurrent intragastric administration of probenecid (50 mg/kg) in 6 healthy mares. Significant difference was not apparent in the pharmacokinetic values of flunixin meglumine with and without concurrent probenecid administration. Significant (P less than or equal to 0.
View Article and Find Full Text PDFInfection remains a major complication following the use of implanted biomaterials. Often these infections are caused by low-virulence organisms or by a mixture of organisms (polymicrobial). In this study two methods were used to quantitate the bacteria which had adhered to poly(methyl methacrylate) (PMMA) samples.
View Article and Find Full Text PDFPolymer composites are being recognized as important implant materials for fracture fixation plates. The use of a composite material is dependent upon the mechanical properties of the material and its biocompatibility. The primary objective of this project was to evaluate 30% chopped-carbon-fiber-reinforced poly(etheretherketone) (CFRPEEK) as a potential material for use as a fracture fixation plate.
View Article and Find Full Text PDFJ Orthop Res
March 1991
The nature and distribution of corrosion products released into the body from orthopaedic implants remains an important issue. Various approaches to study this problem have been taken, such as the injection of metal salts, the injection of corrosion products, analysis of retrieved implants and adjacent tissue, and stimulated corrosion in vivo, with collection of body fluids and tissues for analysis. Tissue culture techniques have also been used to study the cellular response to metal salts or to corrosion or wear products that were generated in a separate environment.
View Article and Find Full Text PDFThe goals of this study were to determine 1) effect of Staphylococcus epidermidis adherence and biofilm production on adherence of the opportunistic pathogens Proteus mirabilis and Pseudomonas aeruginosa to polymethyl methacrylate (PMMA); 2) if the biofilm killed by autoclaving altered adherence of other organisms; 3) if adherence of S. epidermidis to gentamicin-containing PMMA altered adherence of the opportunistic pathogens P. mirabilis and P.
View Article and Find Full Text PDFThe adherence of bacteria to implanted medical devices is believed to be important in the development of implant associated infections. Measures which reduce bacterial adherence should reduce the incidence of these infections. However, in order to assess the importance of adherence, the effectiveness of methods to reduce adherence, and compare data from different laboratories, the conditions of the in vitro studies on adherence need to be specified.
View Article and Find Full Text PDFThe surface of titanium has been modified by covalent attachment of an organic monolayer anchored by a siloxane network. This coating completely covers the metal and allows controlled modification of surface properties by the exposed chemical endgroups of the monolayer forming surfactant. The attachment of such a film allows different bulk materials (e.
View Article and Find Full Text PDFRatings during acute and follow-up care by 35 families having members with traumatic brain injury showed none of the medical facilities met families' needs though some aspects of patients' care were rated higher in hospitals. Findings suggest comprehensive surveys are needed.
View Article and Find Full Text PDF