Background: Asymptomatic carriage of malaria parasites persists even as malaria transmission declines. Low-density infections are often submicroscopic, not detected with rapid diagnostic tests (RDTs) or microscopy but detectable by polymerase chain reaction (PCR).
Methods: To characterize submicroscopic Plasmodium falciparum carriage in an area of declining malaria transmission, asymptomatic persons >5 years of age in rural Bagamoyo District, Tanzania, were screened using RDT, microscopy, and PCR.
Plasmodium ovale curtisi (Poc) and Plasmodium ovale wallikeri (Pow) represent distinct non-recombining Plasmodium species that are increasing in prevalence in sub-Saharan Africa. Though they circulate sympatrically, co-infection within human and mosquito hosts has rarely been described. Separate 18S rRNA real-time PCR assays that detect Poc and Pow were modified to allow species determination in parallel under identical cycling conditions.
View Article and Find Full Text PDFBackground: Asymptomatic malaria may be patent (visible by microscopy) and detectable by rapid malaria diagnostic tests (RDTs), or it may be submicroscopic and only detectable by polymerase chain reaction (PCR).
Methods: To characterize the submicroscopic reservoir in an area of declining malaria transmission, asymptomatic persons >5 years of age in Bagamoyo District, Tanzania, were screened using RDT, microscopy, and PCR. We investigated the size of the submicroscopic reservoir across villages, determined factors associated with submicroscopic parasitemia, and assessed the natural history of submicroscopic malaria over four weeks.
and represent distinct non-recombining malaria species that are increasing in prevalence in sub-Saharan Africa. Though they circulate sympatrically, co-infection within human and mosquito hosts has rarely been described. Separate 18S rRNA real-time PCR assays that detect and were modified to allow species determination in parallel under identical cycling conditions.
View Article and Find Full Text PDFPoint-of-care (POC) tests to detect SARS-CoV-2 antibodies offer quick assessment of serostatus after natural infection or vaccination. We compared the field performance of the BioMedomics COVID-19 IgM/IgG Rapid Antibody Test against an ELISA in 303 participants enrolled in a SARS-CoV-2 household cohort study. The rapid antibody test was easily implemented with consistent interpretation across 14 users in a variety of field settings.
View Article and Find Full Text PDFBackground: Households are hot spots for severe acute respiratory syndrome coronavirus 2 transmission.
Methods: This prospective study enrolled 100 coronavirus disease 2019 (COVID-19) cases and 208 of their household members in North Carolina though October 2020, including 44% who identified as Hispanic or non-White. Households were enrolled a median of 6 days from symptom onset in the index case.
Diagn Microbiol Infect Dis
October 2021
Alternatives to nasopharyngeal sampling are needed to increase capacity for SARS-CoV-2 testing. Among 275 participants, we piloted the collection of nasal mid-turbinate swabs amenable to self-testing, including polyester flocked swabs as well as 3D-printed plastic lattice swabs, placed into viral transport media or an RNA stabilization agent. Flocked nasal swabs identified 104/121 individuals who were PCR-positive for SARS-CoV-2 by nasopharyngeal sampling (sensitivity 87%, 95% CI 79-92%), missing those with low viral load (<10 viral copies/mL).
View Article and Find Full Text PDFBackground: Few prospective studies of SARS-CoV-2 transmission within households have been reported from the United States, where COVID-19 cases are the highest in the world and the pandemic has had disproportionate impact on communities of color.
Methods And Findings: This is a prospective observational study. Between April-October 2020, the UNC CO-HOST study enrolled 102 COVID-positive persons and 213 of their household members across the Piedmont region of North Carolina, including 45% who identified as Hispanic/Latinx or non-white.
Background: Standard nasopharyngeal swab testing for SARS-CoV-2 detection by PCR is not always feasible due to limitations in trained personnel, personal protective equipment, swabs, PCR reagents, and access to cold chain and biosafety hoods.
Methods: We piloted the collection of nasal mid-turbinate swabs amenable to self-testing, including both standard polyester flocked swabs as well as 3D printed plastic lattice swabs, placed into either viral transport media or an RNA stabilization agent. Quantitative SARS-CoV-2 viral detection by RT-qPCR was compared to that obtained by nasopharyngeal sampling as the reference standard.
Atovaquone-proguanil remains effective against multidrug-resistant in Southeast Asia, but resistance is mediated by a single point mutation in cytochrome () that can arise during treatment. Among 14 atovaquone-proguanil treatment failures in a clinical trial in Cambodia, only one recrudescence harbored the mutation Y268C. Deep sequencing did not detect the mutation at baseline or in the first 3 days of treatment, suggesting that it arose Further sequencing across similarly found no low-frequency mutations that were up-selected from baseline to recrudescence.
View Article and Find Full Text PDF