Introduction: This study aims to apply a conditional Generative Adversarial Network (cGAN) to generate synthetic Computed Tomography (sCT) from 0.35 Tesla Magnetic Resonance (MR) images of the thorax.
Methods: Sixty patients treated for lung lesions were enrolled and divided into training (32), validation (8), internal (10,T) and external (10,T) test set.
Background: Organs at risk (OARs) delineation is a crucial step of radiotherapy (RT) treatment planning workflow. Time-consuming and inter-observer variability are main issues in manual OAR delineation, mainly in the head and neck (H & N) district. Deep-learning based auto-segmentation is a promising strategy to improve OARs contouring in radiotherapy departments.
View Article and Find Full Text PDFPurpose: As a discipline in its infancy, online adaptive RT (ART) needs new ontologies and criteria to evaluate the appropriateness of its use in clinical practice. In this experience, we propose a predictive model able to quantify the dosimetric impact due to daily inter-fraction variability in a standard RT breast treatment, to identify in advance the treatment fractions where patients might benefit from an online ART approach.
Methods: The study was focused on right breast cancer patients treated using standard adjuvant RT on an artificial intelligence (AI)-based linear accelerator.
Introduction: The most common intracranial neoplasm diagnosed in adults are brain metastases (BrM). The benefit in terms of clinical control and toxicity for stereotactic radiotherapy (SRT) has been investigated for patients with low load of BrM.
Aim: The aim of this single-institution experience was to investigate the best dose schedule for five-fraction SRT (FFSRT).
Introduction: Bone metastases (BMs) are the common cause of cancer-related pain, as approximately 45% of cancer patients suffer from bone pain (BP). Radiotherapy (RT) is well established as BP treatment strategy; also, other approaches have been shown to be effective in this setting. Radiofrequency thermoablation (RFA) in a combined strategy with RT appears to be feasible and effective in the treatment of metastatic BP ensuring a better quality of life.
View Article and Find Full Text PDFObjective: Radiotherapy (RT) in the head and neck (H&N) site are undoubtedly the most challenging treatments for patients. Older and frail patients are not always able to tolerate it, and there are still no clear guidelines on the type of treatments to be preferred for them. The recommendations for Risk-Adapted H&N Cancer Radiation Therapy during the coronavirus disease 2019 (COVID-19) pandemic provided by the ASTRO-ESTRO consensus statement achieved a strong agreement about hypofractionated RT (HFRT).
View Article and Find Full Text PDFIntroduction: Adjuvant radiation therapy (RT) following primary surgery in women affected by early breast cancer (EBC) plays a central role in reducing local recurrences and overall mortality. The FAST-FORWARD trial recently demonstrated that 1-week hypofractionated adjuvant RT is not inferior to the standard schedule in terms of local relapse, cosmetic outcomes and toxicity. The aim of this in silico study was to evaluate the dosimetric aspects of a 1-week RT course, administered through volumetric modulated arc therapy (VMAT), compared with traditional three-dimensional conformal radiation therapy (3D-CRT) with tangential fields.
View Article and Find Full Text PDFPurpose: To evaluate the performance of eleven Knowledge-Based (KB) models for planning optimization (RapidPlantm (RP), Varian) of Volumetric Modulated Arc Therapy (VMAT) applied to whole breast comprehensive of nodal stations, internal mammary and/or supraclavicular regions.
Methods And Materials: Six RP models have been generated and trained based on 120 VMAT plans data set with different criteria. Two extra-structures were delineated: a PTV for the optimization and a ring structure.
Introduction: Aim of this study is to dosimetrically characterize a new inorganic scintillator designed for magnetic resonance-guided radiotherapy (MRgRT) in the presence of 0.35 tesla magnetic field (B).
Methods: The detector was characterized in terms of signal to noise ratio (SNR), reproducibility, dose linearity, angular response, and dependence by energy, field size, and B orientation using a 6 MV magnetic resonance (MR)-Linac and a water tank.
Background: Upfront single or tandem ASCT still represents an integral part of treatment for patients with multiple myeloma. The combination of intermediate dose (ID) - cyclophosphamide plus G-CSF, has been considered the standard method as mobilization regimen. No prospective randomized clinical trials have compared efficacy and costs using ID - cyclophosphamide against a chemo-free mobilization strategy with G-CSF and plerixafor on demand.
View Article and Find Full Text PDFPurpose: To investigate the performance of various algorithms for deformable image registration (DIR) for propagating regions of interest (ROIs) using multiple commercial platforms, from computed tomography to cone beam computed tomography (CBCT) and megavoltage computed tomography.
Methods And Materials: Fourteen institutions participated in the study using 5 commercial platforms: RayStation (RaySearch Laboratories, Stockholm, Sweden), MIM (Cleveland, OH), VelocityAI and SmartAdapt (Varian Medical Systems, Palo Alto, CA), and ABAS (Elekta AB, Stockholm, Sweden). Algorithms were tested on synthetic images generated with the ImSimQA (Oncology Systems Limited, Shrewsbury, UK) package by applying 2 specific deformation vector fields (DVF) to real head and neck patient datasets.
Purpose: Magnetic resonance-guided adaptive radiotherapy (MRgART) is considered a promising resource for pancreatic cancer, as it allows to online modify the dose distribution according to daily anatomy. This study aims to compare the dosimetric performance of a simplified optimizer implemented on a MR-Linac treatment planning system (TPS) with those obtained using an advanced optimizer implemented on a conventional Linac.
Methods: Twenty patients affected by locally advanced pancreatic cancer (LAPC) were considered.
Med Biol Eng Comput
October 2018
In vivo dosimetry (IVD) is the last step of a radiotherapy quality control program aimed to ensure that the dose delivered is in agreement with that prescribed. IVD procedures based on single detectors are time-consuming and impossible to use for the modern radiotherapy techniques, based on static or kinetic beams (modulated in intensity fluence); this means that more efficient and practical methods are highly recommended. The practical method SOFTDISO, based on the use of electronic portal image device (EPID), provides two tests (i) the R ratio between the reconstructed and the planned isocenter doses to verify an agreement within 5% and (ii) the γ-analysis of the EPID images, to verify γ% ≥ 90% and γ ≤ 0.
View Article and Find Full Text PDFTechnol Cancer Res Treat
August 2016
Purpose: This work reports the extension of a semiempirical method based on the correlation ratios to convert electronic portal imaging devices transit signals into in vivo doses for the step-and-shoot intensity-modulated radiotherapy Siemens beams. The dose reconstructed at the isocenter point Diso, compared to the planned dose, Diso,TPS, and a γ-analysis between 2-dimensional electronic portal imaging device images obtained day to day, seems to supply a practical method to verify the beam delivery reproducibility.
Method: The electronic portal imaging device images were obtained by the superposition of many segment fields, and the algorithm for the Diso reconstruction for intensity-modulated radiotherapy step and shoot was formulated using a set of simulated intensity-modulated radiotherapy beams.
Background: Breast tissue composition is recognized as a strong and independent risk factor for breast cancer. It is a heritable feature, but is also significantly affected by several other elements (e.g.
View Article and Find Full Text PDFThe optical characterization of malignant and benign breast lesions is presented. Time-resolved transmittance measurements were performed in the 630-1060 nm range by means of a 7-wavelength optical mammograph, providing both imaging and spectroscopy information. A total of 62 lesions were analyzed, including 33 malignant and 29 benign lesions.
View Article and Find Full Text PDFObjectives: To evaluate the underestimation rate and clinical relevance of lobular neoplasia in vacuum-assisted breast biopsy (VABB).
Methods: A total of 161 cases of LN were retrieved from 6,435 VABB. The histological diagnosis was ALH (atypical lobular hyperplasia) in 80 patients, LCIS (lobular carcinoma in situ) in 69 patients and PLCIS (pleomorphic lobular carcinoma in situ) in 12 patients.
A time-domain multiwavelength (635 to 1060 nm) optical mammography was performed on 147 subjects with recent x-ray mammograms available, and average breast tissue composition (water, lipid, collagen, oxy- and deoxyhemoglobin) and scattering parameters (amplitude a and slope b) were estimated. Correlation was observed between optically derived parameters and mammographic density [Breast Imaging and Reporting Data System (BI-RADS) categories], which is a strong risk factor for breast cancer. A regression logistic model was obtained to best identify high-risk (BI-RADS 4) subjects, based on collagen content and scattering parameters.
View Article and Find Full Text PDFBreast density is a recognized strong and independent risk factor for developing breast cancer. At present, breast density is assessed based on the radiological appearance of breast tissue, thus relying on the use of ionizing radiation. We have previously obtained encouraging preliminary results with our portable instrument for time domain optical mammography performed at 7 wavelengths (635-1060 nm).
View Article and Find Full Text PDFObjective: To predict presence of invasive component and nodal involvement in women diagnosed preoperatively with ductal carcinoma in situ (DCIS) by vacuum-assisted breast biopsy (VABB).
Materials And Methods: We retrospectively analyzed 733 patients with preoperatively diagnosed DCIS, investigating the association of clinical-radiological variables with invasive component and nodal involvement.
Results: Mammographic size >20 mm and residual lesion on post-VABB mammogram were related to invasive component (both p < 0.
Vacuum-assisted breast biopsy (VABB), which plays a fundamental role in the preoperative assessment of microcalcifications, can also be used (with ultrasound guidance) to obtain histology samples of breast lesions that are visible on ultrasonography. It is particularly useful when the lesion diameter is less than 1 cm. This technique has been used in our institute since 1998, and in this report we analyze our experience with it in 2010.
View Article and Find Full Text PDFAfter a case of Angiostrongylus vasorum (canine lungworm) was diagnosed in the province of Chieti (Italy) in early 2008, parasitological research was conducted to investigate the presence of the parasite in dogs in the area. A total of 178 dogs, 56 carcasses and 122 stool samples were examined between January and September 2008. The carcasses were examined for the presence of adult parasites in the right ventricle and pulmonary artery, and larval forms in the internal organ and brain tissues.
View Article and Find Full Text PDFBreast density is a recognized strong and independent risk factor for breast cancer. We propose the use of time-resolved transmittance spectroscopy to estimate breast tissue density and potentially provide even more direct information on breast cancer risk. Time-resolved optical mammography at seven wavelengths (635 to 1060 nm) is performed on 49 subjects.
View Article and Find Full Text PDFObjective: The purpose of our study was to assess whether in case of total removal of microcalcifications there is still residual tumor on the surgical specimen and, secondarily, to assess whether complete rather than partial excision of the imaging target with microcalcifications may result in increased diagnostic accuracy.
Materials And Methods: We retrospectively reviewed 4,086 stereotactic vacuum-assisted breast biopsy (VABB) procedures for microcalcifications and histologic findings to determine the frequency of malignancy, histologic underestimation, and complete removal of cancer.
Results: No residual microcalcifications on postbiopsy mammograms were seen in 1,594 of 4,047 (39.