Publications by authors named "Menk Ralf H"

Experimental characterization of the structural, electronic and dynamic properties of dilute systems in aqueous solvents, such as nanoparticles, molecules and proteins, are nowadays an open challenge. X-ray absorption spectroscopy (XAS) is probably one of the most established approaches to this aim as it is element-specific. However, typical dilute systems of interest are often composed of light elements that require extreme-ultraviolet to soft X-ray photons.

View Article and Find Full Text PDF

Following the rapid, but independent, diffusion of x-ray spectral and phase-contrast systems, this work demonstrates the first combination of spectral and phase-contrast computed tomography (CT) obtained by using the edge-illumination technique and a CdTe small-pixel (62m) spectral detector. A theoretical model is introduced, starting from a standard attenuation-based spectral decomposition and leading to spectral phase-contrast material decomposition. Each step of the model is followed by quantification of accuracy and sensitivity on experimental data of a test phantom containing different solutions with known concentrations.

View Article and Find Full Text PDF

This paper presents a new flexible compact multi-modal imaging setup referred to as PEPI (Photon-counting Edge-illumination Phase-contrast imaging) Lab, which is based on the edge-illumination (EI) technique and a chromatic detector. The system enables both X-ray phase-contrast (XPCI) and spectral (XSI) imaging of samples on the centimeter scale. This work conceptually follows all the stages in its realization, from the design to the first imaging results.

View Article and Find Full Text PDF

In hard X-ray applications that require high detection efficiency and short response times, such as synchrotron radiation-based Mössbauer absorption spectroscopy and time-resolved fluorescence or photon beam position monitoring, III-V-compound semiconductors, and dedicated alloys offer some advantages over the Si-based technologies traditionally used in solid-state photodetectors. Amongst them, gallium arsenide (GaAs) is one of the most valuable materials thanks to its unique characteristics. At the same time, implementing charge-multiplication mechanisms within the sensor may become of critical importance in cases where the photogenerated signal needs an intrinsic amplification before being acquired by the front-end electronics, such as in the case of a very weak photon flux or when single-photon detection is required.

View Article and Find Full Text PDF

X-ray absorption fine-structure (XAFS) spectroscopy can assess the chemical speciation of the elements providing their coordination and oxidation state, information generally hidden to other techniques. In the case of trace elements, achieving a good quality XAFS signal poses several challenges, as it requires high photon flux, counting statistics and detector linearity. Here, a new multi-element X-ray fluorescence detector is presented, specifically designed to probe the chemical speciation of trace 3d elements down to the p.

View Article and Find Full Text PDF

Purpose: The SYRMA-3D collaboration is setting up a breast computed tomography (bCT) clinical program at the Elettra synchrotron radiation facility in Trieste, Italy. Unlike the few dedicated scanners available at hospitals, synchrotron radiation bCT requires the patient's rotation, which in turn implies a long scan duration (from tens of seconds to few minutes). At the same time, it allows the achievement of high spatial resolution.

View Article and Find Full Text PDF

It has been shown previously both in vitro and in vivo that microbeam irradiation (MBI) can control malignant tumour cells more effectively than the clinically established concepts of broad beam irradiation. With the aim to extend the international capacity for microbeam research, the first MBI experiment at the biomedical beamline SYRMEP of the Italian synchrotron facility ELETTRA has been conducted. Using a multislit collimator produced by the company TECOMET, arrays of quasi-parallel microbeams were successfully generated with a beam width of 50 µm and a centre-to-centre distance of 400 µm.

View Article and Find Full Text PDF

In this paper the back-side-illuminated Percival 2-Megapixel (P2M) detector is presented, along with its characterization by means of optical and X-ray photons. For the first time, the response of the system to soft X-rays (250 eV to 1 keV) is presented. The main performance parameters of the first detector are measured, assessing the capabilities in terms of noise, dynamic range and single-photon discrimination capability.

View Article and Find Full Text PDF

In this study, we explore the behaviour of intracellular magnesium during bone phenotype modulation in a 3D cell model built to mimic osteogenesis. In addition, we measured the amount of magnesium in the mineral depositions generated during osteogenic induction. A two-fold increase of intracellular magnesium content was found, both at three and seven days from the induction of differentiation.

View Article and Find Full Text PDF

The improved performance of third-generation light sources and the advent of next-generation synchrotron radiation facilities require the use of extremely precise monitoring of the main photon-beam parameters, such as position, absolute and relative intensity, and temporal structure. These parameters, and associated real-time feedbacks, are fundamental at the beamline control level and at the machine control level, to improve the stability of the photon beams and to provide bunch-to-bunch quantitative information. Fast response time, high radiation hardness and visible-blind response are main features of photon-beam monitors for VUV and X-ray synchrotron radiation beamlines; hence diamond-based detectors are outstanding candidates.

View Article and Find Full Text PDF

Unlike conventional x-ray attenuation one of the advantages of phase contrast x-ray imaging is its capability of extracting useful physical properties of the sample. In particular the possibility to obtain information from small angle scattering about unresolvable structures with sub-pixel resolution sensitivity has drawn attention for both medical and material science applications. We report on a novel algorithm for the analyzer based x-ray phase contrast imaging modality, which allows the robust separation of absorption, refraction and scattering effects from three measured x-ray images.

View Article and Find Full Text PDF

The International Atomic Energy Agency (IAEA) jointly with the Elettra Sincrotrone Trieste (EST) operates a multipurpose X-ray spectrometry endstation at the X-ray Fluorescence beamline (10.1L). The facility has been available to external users since the beginning of 2015 through the peer-review process of EST.

View Article and Find Full Text PDF

Unlabelled: The use of alginate based microcapsules to deliver drugs and cells with a minimal host interaction is increasingly being proposed. A proficient method to track the position of the microcapsules during such therapies, particularly if they are amenable to commonly used instrumentation, would greatly help the development of such treatments. Here we propose to label the microcapsules with gold nanoparticles to provide a bright contrast on small animal x-ray micro-CT systems enabling single microcapsule detection.

View Article and Find Full Text PDF

Unlabelled: The ability to perform cell tracking using x-ray computed tomography combined with gold nanoparticles has been demonstrated recently on ex vivo samples using different malignant and nonmalignant cell lines. Here we proved the concept of the method for in vivo assessment in a small-animal model of malignant brain tumors. The limitations of the method due to radiation dose constraints were investigated using Monte Carlo simulations.

View Article and Find Full Text PDF

1. Spatially resolved X-ray fluorescence (XRF) spectroscopy with synchrotron radiation is a technique that allows imaging and quantification of chemical elements in biological specimens with high sensitivity. In the present study, we applied XRF techniques at a macro and micro level to carry out drug distribution studies on ex vivo models to confirm the hepatobiliary disposition of the Gd-based magnetic resonance imaging contrast agent B22956/1.

View Article and Find Full Text PDF

We present a compact modular apparatus with a flexible design that will be operated at the DiProI beamline of the Fermi@Elettra free electron laser (FEL) for performing static and time-resolved coherent diffraction imaging experiments, taking advantage of the full coherence and variable polarization of the short seeded FEL pulses. The apparatus has been assembled and the potential of the experimental setup is demonstrated by commissioning tests with coherent synchrotron radiation. This multipurpose experimental station will be open to general users after installation at the Fermi@Elettra free electron laser in 2011.

View Article and Find Full Text PDF

Purpose: To prospectively evaluate the diagnostic contribution of mammography with synchrotron radiation in patients with questionable or suspicious breast abnormalities identified at combined digital mammography (DM) and ultrasonography (US).

Materials And Methods: The ethics committee approved this prospective study, and written informed consent was obtained from all patients. Mammography with synchrotron radiation was performed with a phase-detection technique at a synchrotron radiation laboratory.

View Article and Find Full Text PDF

The ability to track cells in small-animal models of human disease is important because it gives the potential to improve our understanding of the processes of disease progression as well as our understanding of the therapeutic effects of interventions. In this study gold nanoparticles have been used as a permanent marker of implanted normal and malignant cell grafts in combination with a suitable x-ray apparatus. Using x-ray computed tomography the micrometric three-dimensional distribution of these marked cells could be displayed with penetration depth, high cell sensitivity and high spatial resolution in rodent models of human diseases.

View Article and Find Full Text PDF

In the present study, the in vivo distribution of polyelectrolyte multilayer coated gold nanoparticles is shown, starting from the living animal down to cellular level. The coating was designed with functional moieties to serve as a potential nano drug for prion disease. With near infrared time-domain imaging we followed the biodistribution in mice up to 7 days after intravenous injection of the nanoparticles.

View Article and Find Full Text PDF

When small triangular prisms are arranged in arrays which have an overall appearance like an hourglass (in Italian: clessidra) they can focus X-rays owing to a combined action of diffraction and refraction. From the optical point of view these objects can be regarded as a Fresnel variant of concave transmission lenses. Consequently they can provide larger apertures than purely refractive lenses.

View Article and Find Full Text PDF

Clessidra (hour-glass) X-ray lenses have an overall shape of an old hour glass, in which two opposing larger triangular prisms are formed of smaller identical prisms or prism-like objects. In these lenses, absorbing and otherwise optically inactive material was removed with a material-removal strategy similar to that used by Fresnel in the lighthouse lens construction. It is verified that when the single prism rows are incoherently illuminated they can be operated as independent micro-lenses with coinciding image positions for efficient X-ray beam concentration.

View Article and Find Full Text PDF

An analyzer-based X-ray phase contrast imaging (ABI) system with an asymmetrical crystal set-up was mounted at Elettra's SYRMEP beamline. It was the first time that this set-up was implemented at Elettra. Advantages and disadvantages of such a set-up were exploited with quantitative and qualitative studies.

View Article and Find Full Text PDF

An interpolating two-dimensional X-ray imaging detector based on a single-photon counter with gas amplification by GEM (gas electron multiplier) structures is presented. The detector system can be used for time-resolved structure research down to the micro s time domain. The prototype detector has been tested at the SAXS (small-angle X-ray scattering) beamline at ELETTRA synchrotron light source with a beam energy of 8 keV.

View Article and Find Full Text PDF

Objective: To determine the feasibility of detecting the structural orientation in cartilage with Diffraction Enhanced X-Ray Imaging.

Design: Human tali and femoral head specimens were Diffraction Enhanced X-Ray Imaged (DEI) at the SYRMEP beamline at Elettra at various energy levels to detect the architectural arrangement of collagen within cartilage. DEI utilizes a monochromatic and highly collimated beam, with an analyzer crystal that selectively weights out photons according to the angle they have been deviated with respect to the original direction.

View Article and Find Full Text PDF