Purpose: Perfusion MRI reveals important tumor physiological and pathophysiologic information, making it a critical component in managing brain tumor patients. This study aimed to develop a dual-echo 3D spiral technique with a single-bolus scheme to simultaneously acquire both dynamic susceptibility contrast (DSC) and dynamic contrast-enhanced (DCE) data and overcome the limitations of current EPI-based techniques.
Methods: A 3D spiral-based technique with dual-echo acquisition was implemented and optimized on a 3T MRI scanner with a spiral staircase trajectory and through-plane SENSE acceleration for improved speed and image quality, in-plane variable-density undersampling combined with a sliding-window acquisition and reconstruction approach for increased speed, and an advanced iterative deblurring algorithm.
Purpose: Brain MRI is increasingly used in the emergency department (ED), where -weighted MRI is an essential tool for detecting hemorrhage and stroke. The goal of this study was to develop a rapid -weighted MRI technique capable of correcting motion-induced artifacts, thereby simultaneously improving scan time and motion robustness for ED applications.
Methods: A 2D gradient-echo (GRE)-based multishot EPI (msEPI) technique was implemented using a navigator echo for estimating motion-induced errors.
Purpose: This work proposes a 2D/3D hybrid inflow MRA technique for fast scanning and high SNR and contrast-to-noise (CNR) efficiencies.
Methods: Localized quadratic (LQ) encoding was combined with a sliding-slice spiral acquisition. Inflow MRAs around the circle of Willis and the carotid bifurcations were collected on four healthy volunteers.
Axial gradient echo T2*-weighed MRI of the spine is a valuable diagnostic tool with several advantages over axial T2-weighted TSE MRI, but it suffers from a low signal-to-noise ratio (SNR) and inconsistent image quality. This work investigates the potential of spiral MRI to reduce artifacts and produce improved SNR and image quality in axial T2*-weighted gradient echo MRI of the spine of pediatric patients. For the purposes of image quality evaluation, 15 pediatric patients were recruited among those scheduled for a routine spine or brain exam at 1.
View Article and Find Full Text PDFPurpose: Fluid-attenuated inversion recovery (FLAIR) nulls the CSF signal and is widely used in neuro MRI exams. A 3D scan can provide high SNR, contiguous coverage, and reduced sensitivity to through-plane CSF flow. In this work, a 3D spiral FLAIR technique is proposed to improve the image quality of conventional 3D Cartesian FLAIR.
View Article and Find Full Text PDFPurpose: B eddy currents are a subtle but important source of artifacts in spiral MRI. This study illustrates the importance of addressing these artifacts and presents a system response-based eddy current correction strategy using B eddy current phase measurements on a phantom.
Methods: B and linear eddy current system response measurements were estimated from phantom-based measurement and used to predict residual eddy current effects in spiral acquisitions.
Purpose: Optical prospective motion correction substantially reduces sensitivity to motion in neuroimaging of human subjects. However, a major barrier to clinical deployment has been the time-consuming cross-calibration between the camera and MRI scanner reference frames. This work addresses this challenge.
View Article and Find Full Text PDFPurpose: A novel prospective motion correction technique for brain MRI is presented that uses miniature wireless radio-frequency coils, or "wireless markers," for position tracking.
Methods: Each marker is free of traditional cable connections to the scanner. Instead, its signal is wirelessly linked to the MR receiver via inductive coupling with the head coil.
Group level statistical maps of blood oxygenation level dependent (BOLD) signals acquired using functional magnetic resonance imaging (fMRI) have become a basic measurement for much of systems, cognitive and social neuroscience. A challenge in making inferences from these statistical maps is the noise and potential confounds that arise from the head motion that occurs within and between acquisition volumes. This motion results in the scan plane being misaligned during acquisition, ultimately leading to reduced statistical power when maps are constructed at the group level.
View Article and Find Full Text PDFPurpose: To develop and implement a clinical DTI technique suitable for the pediatric setting that retrospectively corrects for large motion without the need for rescanning and/or reacquisition strategies, and to deliver high-quality DTI images (both in the presence and absence of large motion) using procedures that reduce image noise and artifacts.
Materials And Methods: We implemented an in-house built generalized autocalibrating partially parallel acquisitions (GRAPPA)-accelerated diffusion tensor (DT) echo-planar imaging (EPI) sequence at 1.5T and 3T on 1600 patients between 1 month and 18 years old.
Despite rigid-body realignment to compensate for head motion during an echo-planar imaging time-series scan, nonrigid image deformations remain due to changes in the effective shim within the brain as the head moves through the B(0) field. The current work presents a combined prospective/retrospective solution to reduce both rigid and nonrigid components of this motion-related image misalignment. Prospective rigid-body correction, where the scan-plane orientation is dynamically updated to track with the subject's head, is performed using an active marker setup.
View Article and Find Full Text PDFHead motion is a fundamental problem in functional magnetic resonance imaging and is often a limiting factor in its clinical implementation. This work presents a rigid-body motion correction strategy for echo-planar imaging sequences that uses micro radiofrequency coil "active markers" for real-time, slice-by-slice prospective correction. Before the acquisition of each echo-planar imaging-slice, a short tracking pulse-sequence measures the positions of three active markers integrated into a headband worn by the subject; the rigid-body transformation that realigns these markers to their initial positions is then fed back to dynamically update the scan-plane, maintaining it at a fixed orientation relative to the head.
View Article and Find Full Text PDFPatient motion during an MRI exam can result in major degradation of image quality, and is of increasing concern due to the aging population and its associated diseases. This work presents a general strategy for real-time, intraimage compensation of rigid-body motion that is compatible with multiple imaging sequences. Image quality improvements are established for structural brain MRI acquired during volunteer motion.
View Article and Find Full Text PDF