Publications by authors named "Meir Nitzan"

Photoplethysmography is a key sensing technology which is used in wearable devices such as smartwatches and fitness trackers. Currently, photoplethysmography sensors are used to monitor physiological parameters including heart rate and heart rhythm, and to track activities like sleep and exercise. Yet, wearable photoplethysmography has potential to provide much more information on health and wellbeing, which could inform clinical decision making.

View Article and Find Full Text PDF

On average, arterial oxygen saturation measured by pulse oximetry (SpO) is higher in hypoxemia than the true oxygen saturation measured invasively (SaO), thereby increasing the risk of occult hypoxemia. In the current article, measurements of SpO on 17 cyanotic newborns were performed by means of a Nellcor pulse oximeter (POx), based on light with two wavelengths in the red and infrared regions (660 and 900 nm), and by means of a novel POx, based on two wavelengths in the infrared region (761 and 820 nm). The SpO readings from the two POxs showed higher values than the invasive SaO readings, and the disparity increased with decreasing SaO.

View Article and Find Full Text PDF

Personalized management of diseases by considering relevant patient features enables optimal treatment, instead of management according to an average patient. Precision management of hypertension is important, because both susceptibility to complications and response to treatment vary between individuals. While the use of genomic and proteomic personal features for widespread precision hypertension management is not practical, other features, such as age, ethnicity, and cardiovascular diseases, have been utilized in guidelines for hypertension management.

View Article and Find Full Text PDF

Adequate oxygen delivery to a tissue depends on sufficient oxygen content in arterial blood and blood flow to the tissue. Oximetry is a technique for the assessment of blood oxygenation by measurements of light transmission through the blood, which is based on the different absorption spectra of oxygenated and deoxygenated hemoglobin. Oxygen saturation in arterial blood provides information on the adequacy of respiration and is routinely measured in clinical settings, utilizing pulse oximetry.

View Article and Find Full Text PDF

Objective: Factors described as contributors to the 'penumbra effect' in relation to pulse oximetry include optical shunting, circulatory anastomoses and probe parallelity. This study aimed to clarify the main underlying mechanism involved.

Study Design: Prospective clinical trial.

View Article and Find Full Text PDF

Oxygen saturation in arterial blood (SaO₂) provides information about the performance of the respiratory system. Non-invasive measurement of SaO₂ by commercial pulse oximeters (SpO₂) make use of photoplethysmographic pulses in the red and infrared regions and utilizes the different spectra of light absorption by oxygenated and de-oxygenated hemoglobin. Because light scattering and optical path-lengths differ between the two wavelengths, commercial pulse oximeters require empirical calibration which is based on SaO₂ measurement in extracted arterial blood.

View Article and Find Full Text PDF

Objective: We aimed to correlate photoplethysmographic parameters with stroke volume in infants with PDA. Photoplethysmography constitutes the optical signal in pulse oximetry.

Study Design: Stroke volume was determined echocardiographically.

View Article and Find Full Text PDF

Objective: The ductus arteriosus is a blood vessel that connects the pulmonary artery to the descending aorta during fetal life and generally undergoes spontaneous closure shortly after birth. In premature neonates it often fails to close (patent ductus arteriosus-PDA), which can result in diversion of a significant part of the left-ventricular cardiac output to the pulmonary circulation. This left-to-right shunt may result in significant increase of pulmonary blood flow and decrease of systemic perfusion (hemodynamically significant PDA-hsPDA), which may lead to severe neonatal morbidity.

View Article and Find Full Text PDF

The commonly used techniques for systolic blood pressure (SBP) and diastolic blood pressure (DBP) measurement are the auscultatory Korotkoff-based sphygmomanometry and oscillometry. The former technique is relatively accurate but is limited to a physician's office because its automatic variant is subject to noise artifacts. Consequently, the Korotkoff-based measurement overestimates the blood pressure in some patients due to white coat effect, and because it is a single measurement, it cannot properly represent the variable blood pressure.

View Article and Find Full Text PDF

The value of oxygen saturation in venous blood, SvO, has important clinical significance since it is related to the tissue oxygen utilization, which is related to the blood flow to the tissue and to its metabolism rate. However, existing pulse oximetry techniques are not suitable for blood in veins. In the current study we examine the feasibility of difference oximetry to assess SvO by using two near-infrared wavelengths and collecting the backscattered light from two photodetectors located at different distances from the light source.

View Article and Find Full Text PDF

Oxygen saturation in the arterial blood (SaO2) provides information on the adequacy of respiratory function. SaO2 can be assessed noninvasively by pulse oximetry, which is based on photoplethysmographic pulses in two wavelengths, generally in the red and infrared regions. The calibration of the measured photoplethysmographic signals is performed empirically for each type of commercial pulse-oximeter sensor, utilizing in vitro measurement of SaO2 in extracted arterial blood by means of co-oximetry.

View Article and Find Full Text PDF

The assessment of oxygen saturation in arterial blood by pulse oximetry (SpO₂) is based on the different light absorption spectra for oxygenated and deoxygenated hemoglobin and the analysis of photoplethysmographic (PPG) signals acquired at two wavelengths. Commercial pulse oximeters use two wavelengths in the red and infrared regions which have different pathlengths and the relationship between the PPG-derived parameters and oxygen saturation in arterial blood is determined by means of an empirical calibration. This calibration results in an inherent error, and pulse oximetry thus has an error of about 4%, which is too high for some clinical problems.

View Article and Find Full Text PDF

In the current study, a non-invasive technique for systolic blood pressure (SBP) measurement based on the detection of photoplethysmographic (PPG) pulses during pressure-cuff deflation was compared to sphygmomanometry-the Korotkoff sounds technique. The PPG pulses disappear for cuff-pressures above the SBP value and reappear when the cuff-pressure decreases below the SBP value. One hundred and twenty examinations were performed on forty subjects.

View Article and Find Full Text PDF

The oxygen saturation of the systemic arterial blood is associated with the adequacy of respiration, and can be measured non-invasively by pulse oximetry in the systemic tissue. The oxygen saturation of the blood in the pulmonary artery, the mixed venous blood, reflects the balance between oxygen supply to the systemic tissues and their oxygen demand. The mixed venous oxygen saturation has also clinical significance because it is used in Fick equation for the quantitative measurement of cardiac output.

View Article and Find Full Text PDF

Changes in finger tissue blood volume (TBV) measured by light transmission and in laser Doppler flow (LDF) were obtained during long breathing (of 12 s period) and associated with the respiratory phases, inspiration and expiration. For fifteen out of sixteen subjects TBV and LDF started to decrease 0-2 s after the start of expiration and increased during inspiration but the start of increase occurred before the start of inspiration, showing that the respiratory-induced changes in TBV and LDF are mainly associated with the expiration. Decrease of TBV and LDF after expiration was also found during the inspiratory gasps

View Article and Find Full Text PDF

Background: Automatic measurement of arterial blood pressure is important, but the available commercial automatic blood pressure meters, mostly based on oscillometry, are of low accuracy.

Methods: In this study, we present a cuff-based technique for automatic measurement of systolic blood pressure, based on photoplethysmographic signals measured simultaneously in fingers of both hands. After inflating the pressure cuff to a level above systolic blood pressure in a relatively slow rate, it is slowly deflated.

View Article and Find Full Text PDF

Pulse oximetry is an optical technique for the assessment of oxygen saturation in arterial blood and is based on the different light absorption spectra for oxygenated and deoxygenated hemoglobin and on two-wavelength photoplethysmographic (PPG) measurement of arterial blood volume increase during systole. The technique requires experimental calibration for the determination of the relationship between PPG-derived parameters and arterial oxygen saturation, and this calibration is a source of error in the method. We suggest a three-wavelength PPG technique for the measurement of arterial oxygen saturation that has no need for calibration if the three wavelengths are properly selected in the near-infrared region.

View Article and Find Full Text PDF

Purpose: We tested the hypothesis that the development of sympathectomy-mediated vasodilatation is dependent on the concentration rather than the dose of epidural local anesthetic administered.

Methods: Sixty subjects receiving lumbar epidural bupivacaine were randomised to one of three groups: A: 10 ml 0.5% (50 mg); B: 10 ml 0.

View Article and Find Full Text PDF

Photoplethysmography (PPG) measures the cardiac-induced fluctuations and other changes in tissue blood volume by light transmission measurement. In the current study, light transmission was simultaneously measured in the two index fingers of healthy subjects, while the brachial artery in the left arm was occluded by a pressure cuff, so that no PPG signal appeared in the left finger. Correlated respiratory-induced changes in the PPG baseline in the right hand and in the light transmission in the left hand were found, indicating respiratory-induced blood volume changes in the finger distal to the occluded artery.

View Article and Find Full Text PDF

The aim of this study was to examine the effect on distal arteries of external pressure, applied by upper arm sphygmomanometer cuff. Photoplethysmographic (PPG) signals were measured on the index fingers of 44 healthy male subjects, during the slow decrease of cuff air pressure. For each pulse the ratio of PPG amplitude to its baseline (AM/BL) and its time delay (deltaTD) relative to the contralateral hand were determined as a function of cuff pressure.

View Article and Find Full Text PDF

Brain autonomic control is asymmetrical, the left hemisphere affecting predominantly parasympathetic function and the right hemisphere affecting predominantly sympathetic function. It is not known whether the extent of autonomic activation is altered in migraine, although the fact that some migraineurs express parasympathetic features such as facial flushing, lacrimation and rhinorrhoea might suggest increased parasympathetic activation. We instilled diluted soapy eyedrops and measured (i) the trigemino-parasympathetic reflex by the vasodilator response of forehead skin bilaterally using photoplethysmography; (ii) the somato-sympathetic reflex by vasoconstriction in the index finger; and (iii) heart rate response.

View Article and Find Full Text PDF

Several lines of evidence support involvement of the parasympathetic system in migraine: (i) migraine-associated symptoms, such as exaggerated facial flushing, lacrimation and rhinorrhea; (ii) increased levels of cranial venous vasoactive intestinal peptide in migraineurs during attacks; and (iii) reports of migraine pain alleviation by intranasal instillation of lidocaine, which can block some of the parasympathetic outflow to the cranium. This study assessed cranial parasympathetic function in migraineurs in between attacks, assuming that abnormal function might imply involvement of the parasympathetics in migraine pathogenesis. We tested 39 female migraineurs outside attacks, of whom 11 had bilateral pain, 20 unilateral at a specific side and eight alternating unilateral head pain, and 16 controls.

View Article and Find Full Text PDF

A PHP Error was encountered

Severity: Warning

Message: fopen(/var/lib/php/sessions/ci_sessionom5jg6qumo6rgg068178o7roolv7e4a5): Failed to open stream: No space left on device

Filename: drivers/Session_files_driver.php

Line Number: 177

Backtrace:

File: /var/www/html/index.php
Line: 316
Function: require_once

A PHP Error was encountered

Severity: Warning

Message: session_start(): Failed to read session data: user (path: /var/lib/php/sessions)

Filename: Session/Session.php

Line Number: 137

Backtrace:

File: /var/www/html/index.php
Line: 316
Function: require_once