Microplastic (MP) removal by coagulation/flocculation followed by settling was studied in a secondary wastewater treatment plant (WWTP) effluent matrix. MP concentration in size range <10 µm in wastewater is currently unknown due to the exclusion of this size range in many studies and due to difficulties in MP quantification. WWTP effluent samples were spiked with a known amount of polystyrene spheres of two different sizes 1 µm and 6.
View Article and Find Full Text PDFThe effects of different parameters including membrane type (regenerated cellulose and polysulphone), transmembrane pressure (TMP), the content of oil in the feed, the flow velocity of the feed and pH on the ultrafiltration of an emulsion of kerosene in water were studied. It was found that the important factors affecting ultrafiltration were, in order, membrane type, pressure and oil concentration. The greatest flux at the optimum conditions here of 3 bar, an oil content of 3% (v/v) and with membrane type C30F was predicted as 108 L/(m(2)h) that was within the range of the confidence limit of the measured value of 106 L/(m(2)h).
View Article and Find Full Text PDF