Background: Bronchopulmonary sequestration (BPS) has long been identified in patients with congenital diaphragmatic hernia (CDH), however the reported incidence in the literature varies widely and is not based on large series.
Methods: Version 4 of the Congenital Diaphragmatic Hernia Study Group (CDHSG) included questions specifically identifying BPS-associated cases. The data were prospectively collected between 2015 and 2020.
Introduction: The purpose of this study is to evaluate splenic effects during artificial placenta (AP) support.
Methods: AP lambs (118-121 d, n = 14) were delivered and placed on the AP support for a goal of 10-14 days. Cannulation used right jugular drainage and umbilical vein reinfusion.
An artificial placenta (AP) utilizing extracorporeal life support (ECLS) could protect premature lungs from injury and promote continued development. Preterm lambs at estimated gestational age (EGA) 114-128 days (term = 145) were delivered by Caesarian section and managed in one of three groups: AP, mechanical ventilation (MV), or tissue control (TC). Artificial placenta lambs (114 days EGA, n = 3; 121 days, n = 5) underwent venovenous (VV)-ECLS with jugular drainage and umbilical vein reinfusion for 7 days, with a fluid-filled, occluded airway.
View Article and Find Full Text PDFPurpose: We hypothesized that surgical energy could be used to create hysterotomies in open fetal surgery.
Study Design: Initial studies compared the LigaSure Impact and Harmonic ACE + 7 Shears in the efficiency of hysterotomy and thermal damage. Pregnant ewes at an estimated gestational age (EGA) of 116 to 120 days (term = 145; = 7) underwent hysterotomy using either device.
Purpose: An artificial placenta (AP) utilizing extracorporeal life support (ECLS) could avoid the harm of mechanical ventilation (MV) while allowing the lungs to develop.
Methods: AP lambs (n = 5) were delivered at 118 days gestational age (GA; term = 145 days) and placed on venovenous ECLS (VV-ECLS) with jugular drainage and umbilical vein reinfusion. Lungs remained fluid-filled.
Background: An Artificial Placenta (AP) utilizing extracorporeal life support (ECLS) could revolutionize care of extremely premature newborns, but its effects on gastrointestinal morphology and injury need investigation.
Methods: Lambs (116-121days GA, term=145; n=5) were delivered by C-section, cannulated for ECLS, had total parenteral nutrition (TPN) provided, and were supported for 7days before euthanasia. Early and Late Tissue Controls (ETC, n=5 and LTC, n=5) delivered at 115-121days and 125-131days, respectively, were immediately sacrificed.
Purpose: Survivors of congenital diaphragmatic hernia (CDH) face high morbidity. We studied the neurodevelopmental outcomes of CDH survivors at a single institution.
Methods: CDH survivors born July 2006-March 2016 at a free-standing children's hospital were reviewed.
Background: Extremely premature neonates suffer high morbidity and mortality. An artificial placenta (AP) using extracorporeal life support (ECLS) is a promising therapy.
Objectives: We hypothesized that intratracheal perfluorocarbon (PFC) instillation during AP support would reduce lung injury and promote lung development relative to intratracheal amniotic fluid or crystalloid.
Introduction: Indications for thoracoscopic versus open approaches to repair congenital diaphragmatic hernia (CDH) are unclear as the variability in defect size, disease severity and patient characteristics pose a challenge. Few studies use a patient and disease-matched comparison of techniques. We aimed to compare the clinical outcomes of open versus thoracoscopic repairs of small to moderate sized hernia defects in a low risk population.
View Article and Find Full Text PDFPurpose: The relationship between pulmonary hypoplasia and pulmonary arterial hypertension (PHTN) in patients with congenital diaphragmatic hernia (CDH) remains ill-defined. We hypothesized that prenatal estimates of lung size would directly correlate with PHTN severity.
Methods: Infants with isolated CDH (born 2004-2015) at a single institution were included.
Introduction: Preoperative determination of perforated versus acute appendicitis can be difficult. We compared CT and MRI performance in diagnosing perforated appendicitis, and created diagnostic criteria.
Methods: We retrospectively reviewed all pediatric patients who underwent appendectomy within one day of CT or MRI between 1/1/2013 and 1/16/2016.
Purpose: This study sought to evaluate prenatal markers' ability to predict severe congenital diaphragmatic hernia(CDH) and assess this subgroup's morbidity and mortality.
Methods: A retrospective review was performed between 2006 and 2014. Prenatal criteria for severe CDH included: liver herniation, lung-to-head ratio (LHR) <1 on prenatal ultrasound and/or observed-to-expected LHR (o/eLHR) <25%, and/or observed-to-expected total lung volume (o/eTLV) <25% on fetal MRI.
Since its introduction to bedside clinical practice over 40 years ago, extracorporeal life support (ECLS) has been continually changing and improving as a life-saving technology. Extracorporeal life support disrupts the normal finely maintained balance of coagulation and fibrinolysis by exposing large amounts of blood to nonendothelial surfaces. This leads to an inflammatory response with activation of the coagulation cascade and the need for systemic anticoagulation.
View Article and Find Full Text PDFBackground. Lung injury prediction score (LIPS) is valuable for early recognition of ventilated patients at high risk for developing acute respiratory distress syndrome (ARDS). This study analyzes the value of LIPS in predicting ARDS and mortality among ventilated surgical patients.
View Article and Find Full Text PDFA novel electrochemically controlled release method for nitric oxide (NO) (based on electrochemical reduction of nitrite ions) is combined with an amperometric oxygen sensor within a dual lumen catheter configuration for the continuous in vivo sensing of the partial pressure of oxygen (PO2) in blood. The on-demand electrochemical NO generation/release method is shown to be fully compatible with amperometric PO2 sensing. The performance of the sensors is evaluated in rabbit veins and pig arteries for 7 and 21 h, respectively.
View Article and Find Full Text PDF