Purpose: Currently, no gold standard exists for 3D analysis of virtually planned surgery accuracy postoperatively. The aim of this study was to present a new, validated and standardised methodology for 3D postoperative assessment of surgical accuracy in patients undergoing 3D virtually planned and guided corrective osteotomies.
Methods: All patients who underwent 3D planned corrective osteotomy in 2021-2022 at our center with a postoperative CT were included.
: Three-dimensional (3D) technology is increasingly applied in the surgical treatment of distal radial fractures and may optimize surgical planning, improve fracture reduction, facilitate implant and screw positioning, and thus prevent surgical complications. The main research questions of this review were as follows: (1) "How do 3D-assisted versus 2D-assisted distal radius fracture surgery compare in terms of intraoperative metrics (i.e.
View Article and Find Full Text PDFEur J Trauma Emerg Surg
December 2024
Purpose: Automatic virtual reconstruction of complex fractures would be helpful for pre-operative surgical planning. We developed a statistical shape model (SSM) which contains data of 200 intact 3D hemipelves. It allows for quantification of shape differences and is able to reconstruct abnormal shaped pelvises.
View Article and Find Full Text PDFPhilos Trans A Math Phys Eng Sci
April 2024
Geodiversity and geosystem services are confronting global threats. However, the majority of conservation strategies tend to overlook the geological component within ecosystems. The existing literature centres on biodiversity, ecosystem services and their economic valuation.
View Article and Find Full Text PDFPurpose: There is a debate whether corrective osteotomies of the distal radius should be performed using a 3D work-up with pre-contoured conventional implants (i.e., of-the-shelf) or patient-specific implants (i.
View Article and Find Full Text PDFWe performed a systematic review to compare conventional (2-D) versus 3-D-guided corrective osteotomies regarding intraoperative results, patient-reported outcome measures, range of motion, incidence of complications and pain score. PubMed (MEDLINE), Embase and Cochrane CENTRAL were searched, and 53 articles were included, reporting 1257 patients undergoing forearm corrective osteotomies between 2010 and 2022. 3-D-guided surgery resulted in a greater improvement in median Disabilities of the Arm, Shoulder and Hand (DASH) score (28, SD 7 vs.
View Article and Find Full Text PDFPurpose: A substantial proportion of conventional tibial plateau plates have a poor fit, which may result in suboptimal fracture reduction due to applied -uncontrolled- compression on the bone. This study aimed to assess whether patient-specific osteosyntheses could facilitate proper fracture reduction in medial tibial plateau fractures.
Methods: In three Thiel embalmed human cadavers, a total of six tibial plateau fractures (three Schatzker 4, and three Schatzker 6) were created and CT scans were made.
Displacement of the anterior and posterior column complicates decision making for both-column acetabular fractures. We questioned whether pelvic surgeons agree on treatment strategy, and whether the use of virtual 3D reconstructions changes the treatment strategy of choice. A nationwide cross-sectional survey was performed in all pelvic trauma centers in the Netherlands.
View Article and Find Full Text PDFPurpose: Currently used classification systems and measurement methods are insufficient to assess fracture displacement. In this study, a novel 3D measure for fracture displacement is introduced and associated with risk on conversion to total knee arthroplasty (TKA).
Methods: A multicenter cross-sectional study was performed including 997 patients treated for a tibial plateau fracture between 2003 and 2018.
Introduction: Gap and step-off measurements are generally used in the surgical decision-making process of distal radius fractures. Unfortunately, there is no consensus on treatment choice as these measurements are prone to inter- and intraobserver variability. In this study, we aim to introduce a new 3D fracture quantification method and compare it to conventional fracture analysis.
View Article and Find Full Text PDFThis study aims to develop a three-dimensional (3D) measurement for acetabular fracture displacement, determine the inter- and intra-observer variability, and correlate the measurement with clinical outcome. Three-dimensional models were created for 100 patients surgically treated for acetabular fractures. The ‘3D gap area’, the 3D surface between all the fracture fragments, was developed.
View Article and Find Full Text PDFCorrective osteotomy surgery for long bone anomalies can be very challenging since deformation of the bone is often present in three dimensions. We developed a two-step approach for 3D-planned corrective osteotomies which consists of a cutting and reposition guide in combination with a conventional osteosynthesis plate. This study aimed to assess accuracy of the achieved corrections using this two-step technique.
View Article and Find Full Text PDFDirectly after birth a newborn was found to have distinctive skin lesions on her face. The lesions were suspicious for neonatal lupus. Her asymptomatic mother tested positive for anti-SSA/Ro and anti-SSB/La antibodies.
View Article and Find Full Text PDFAs 2D quantitative measurements are often insufficient, a standardized 3D quantitative measurement method was developed to analyze mandibular condylar fractures, and correlate the results with the mandibular condylar fracture classifications of Loukota and Spiessl and Schroll and clinical parameters. Thirty-two patients with a unilateral mandibular condylar fracture were evaluated using OPT, 2D (CB)CT images, and 3D imaging to measure the extent of the fractures. The maximum mouth opening (MMO) was measured.
View Article and Find Full Text PDFPurpose: Pelvic ring injuries are known to affect the patients' daily life in terms of physical functioning and quality of life (QoL). Still, prospective studies on the patient's perception over the first 2 years of rehabilitation are lacking. Therefore, patients cannot be properly informed about whether or when they will return to their pre-existing level of physical functioning and QoL.
View Article and Find Full Text PDFObjectives: Needle-free jet injectors have been used in dermatological practice for many years. However, predefined clinical endpoints that guide physicians to choose optimal device settings have not been clearly defined. Here, we evaluate immediate skin responses as clinical endpoints for needle-free jet injector treatments.
View Article and Find Full Text PDFThree-dimensional technology is increasingly being used in acetabular fracture treatment. No systematic reviews are available about the added clinical value of 3D-assisted acetabular fracture surgery compared to conventional surgery. Therefore, this study aimed to investigate whether 3D-assisted acetabular fracture surgery compared to conventional surgery improves surgical outcomes in terms of operation time, intraoperative blood loss, intraoperative fluoroscopy usage, complications, and postoperative fracture reduction, and whether it improves physical functioning.
View Article and Find Full Text PDFThere has been an exponential growth in the use of advanced technologies for three-dimensional (3D) virtual pre- and intra-operative planning of pelvic ring injury surgery but potential benefits remain unclear. The purpose of this study was to evaluate differences in intra- and post-operative results between 3D and conventional (2D) surgery. A systematic review was performed including published studies between 1 January 2010 and 22 May 2020 on all available 3D techniques in pelvic ring injury surgery.
View Article and Find Full Text PDFThe assessment of gaps and steps in acetabular fractures is challenging. Data from various imaging techniques to enable accurate quantification of acetabular fracture displacement are limited. The aim of this study was to assess the accuracy of pelvic radiographs, intraoperative fluoroscopy, and computed tomography (CT) in detecting gaps and step-offs in acetabular fractures.
View Article and Find Full Text PDFDue to the complex anatomical shape of the pelvis, screw placement can be challenging in acetabular fracture surgery. This study aims to assess the accuracy of screw placement using patient-specific surgical drilling guides applied to pre-contoured conventional implants in acetabular fracture surgery. CT scans were made of four human cadavers to create 3D models of each (unfractured) pelvis.
View Article and Find Full Text PDFImportance: In acetabular fracture surgery, achieving an optimal reconstruction of the articular surface decreases the risk of osteoarthritis and the subsequent need for total hip arthroplasty. However, no one-size-fits-all osteosynthesis plate is available owing to differences in fracture patterns and variations in pelvic anatomy. Currently, osteosynthesis plates need to be manually contoured intraoperatively, often resulting in inadequate reduction and fixation of the fractured segments.
View Article and Find Full Text PDF