Publications by authors named "Meertens H"

Objectives: To explore the effects of computed tomography (CT) image characteristics and B-spline knot spacing (BKS) on the spatial accuracy of a B-spline deformable image registration (DIR) in the head-and-neck geometry.

Methods: The effect of image feature content, image contrast, noise, and BKS on the spatial accuracy of a B-spline DIR was studied. Phantom images were created with varying feature content and varying contrast-to-noise ratio (CNR), and deformed using a known smooth B-spline deformation.

View Article and Find Full Text PDF

Background: Consistent delineation of patient anatomy becomes increasingly important with the growing use of highly conformal and adaptive radiotherapy techniques. This study investigates the magnitude and 3D localization of interobserver variability of organs at risk (OARs) in the head and neck area with application of delineation guidelines, to establish measures to reduce current redundant variability in delineation practice.

Methods: Interobserver variability among five experienced radiation oncologists was studied in a set of 12 head and neck patient CT scans for the spinal cord, parotid and submandibular glands, thyroid cartilage, and glottic larynx.

View Article and Find Full Text PDF

Purpose: To assess in a rat model whether adding a subtolerance dose in a region adjacent to a high-dose irradiated subvolume of the parotid gland influences its response (bath-and-shower effect).

Methods And Materials: Irradiation of the whole, cranial 50%, and/or the caudal 50% of the parotid glands of Wistar rats was performed using 150-MeV protons. To determine suitable (i.

View Article and Find Full Text PDF

Purpose: To assess the association between the dose distributions in the rectum and late Radiation Therapy Oncology Group and the European Organisation for Research and Treatment of Cancer (RTOG/EORTC), Late Effects of Normal Tissue SOMA, and Common Terminology Criteria for Adverse Events (CTCAE) version 3.0 graded rectal toxicity among patients with prostate cancer treated with RT.

Methods And Materials: Included in the study were 124 patients who received three-dimensional conformal RT for prostate cancer to a total dose of 70 Gy in 2-Gy fractions.

View Article and Find Full Text PDF

Purpose: To test the hypothesis that heart irradiation increases the risk of a symptomatic radiation-induced loss of lung function (SRILF) and that this can be well-described as a modulation of the functional reserve of the lung.

Methods And Materials: Rats were irradiated with 150-MeV protons. Dose-response curves were obtained for a significant increase in breathing frequency after irradiation of 100%, 75%, 50%, or 25% of the total lung volume, either including or excluding the heart from the irradiation field.

View Article and Find Full Text PDF

Purpose: In this study we investigated whether the position of head and neck cancer patients during radiotherapy could be determined from portal images of oblique radiation beams. Currently applied additional anterior posterior (AP) and lateral verification beams could then be abandoned.

Method: The patient position was determined from portal images of the oblique radiation beams and compared with that determined from AP and lateral verification beams.

View Article and Find Full Text PDF

Purpose: Radiation-induced pulmonary toxicity is characterized by dose, region, and time-dependent severe changes in lung morphology and function. This study sought to determine the relation between the structural and functional changes in the irradiated rat lung at three different phases after irradiation.

Materials And Methods: Six groups of animals were irradiated to 16-22 Gy to six different lung regions, each containing 50% of the total lung volume.

View Article and Find Full Text PDF

The aim of this study was to estimate the accuracy and reproducibility of citric-acid-stimulated parotid saliva sampling. In healthy volunteers a strong correlation (r2 = 0.79) between flow rates from the left and right parotid gland was observed.

View Article and Find Full Text PDF

In many thoracic cancers, the radiation dose that can safely be delivered to the target volume is limited by the tolerance dose of the surrounding lung tissue. It has been hypothesized that irradiation of the heart may be an additional risk factor for the development of early radiation-induced lung morbidity. In the current study, the dependence of lung tolerance dose on heart irradiation is determined.

View Article and Find Full Text PDF

Purpose: To detect volume effects and possible regional differences in radiosensitivity of the rat parotid gland.

Methods And Materials: Parotid glands of male albino Wistar rats were locally X-irradiated, with collimators with conformal radiation portals used to supply 100% volume and 50% cranial/caudal partial volumes. High-resolution magnetic resonance imaging was used to provide the outlines of the parotid glands.

View Article and Find Full Text PDF

Purpose: To investigate dose distributions in partial-volume irradiation experiments in small experimental animals, in particular the parotid gland of rat.

Materials And Methods: High-resolution magnetic resonance imaging images were made that provided the outlines of the parotid glands, which were used to design collimators with conformal radiation ports for 100 and 50% cranial/caudal partial-volume irradiation. A protocol for absolute dosimetry was designed and relative dose measurements were performed.

View Article and Find Full Text PDF

Purpose: The purpose of this study was to explore regional differences in radiosensitivity of rat lung using lung function and computed tomography (CT) density as endpoints.

Methods: At first, CT scans were used to determine rat lung volumes. The data obtained enabled the design of accurate collimators to irradiate 50% of the total lung volume for the apex, base, left, right, mediastinal and lateral part of the lung.

View Article and Find Full Text PDF

It was studied whether differences in acute radiosensitivity exist between parotid and submandibular/sublingual glands. The results revealed that salivary flow rates decreased dramatically during the first 2 weeks of radiotherapy. Neither recovery nor significant differences were observed between the production of saliva from the parotid and submandibular/sublingual glands during the 13 weeks observation period.

View Article and Find Full Text PDF

Purpose: Usually, models that predict normal tissue complication probability (NTCP) are fitted to clinical data with the maximum likelihood (ML) method. This method inevitably causes a loss of information contained in the data. In this study, an alternative method is investigated that calculates the parameter probability distribution (PD), and, thus, conserves all information.

View Article and Find Full Text PDF

Background And Purpose: The three-dimensional (3D) dose distribution in combination with 3D anatomy of 13 patients treated for cervical carcinoma with intracavitary brachytherapy was analyzed. The aim of this study was to determine the correlation between a dose value obtained from the integral dose volume histogram (DVH) of the rectum and (a) the Nederlands Kanker Instituut (NKI) point of reference for the rectum dose (R) and (b) the highest dose to the frontal rectum wall in the transverse CT slice near the top of the vagina through point R.

Results: The correlation between the DVH rectum dose value for 2 cm3 in the highest dose region and the rectum dose at point R was poor (regression coefficient 0.

View Article and Find Full Text PDF

We monitored 10 patients with unresected (9) or partially resected (1) supratentorial gliomas with 11C-tyrosine position emission tomography (TYR-PET) before and after radiotherapy. TYR-PET tumour volumes were measured using a threshold technique. In seven patients the tumour volume decreased after radiotherapy, although all gliomas persisted on TYR-PET images.

View Article and Find Full Text PDF

A quality control system especially designed for dosimetry in scanning proton beams has been designed and tested. The system consists of a scintillating screen (Gd2O2S:Tb), mounted at the beam-exit side of a phantom, and observed by a low noise CCD camera with a long integration time. The purpose of the instrument is to make a fast and accurate two-dimensional image of the dose distribution at the screen position in the phantom.

View Article and Find Full Text PDF

The purpose of this study is to develop an experimental model to measure localized radiation-induced lung injury using multiple end-points including breathing frequency, high-resolution computed tomography (CT), and radionuclide perfusion. The rats were anesthetized and the right lung irradiated with a single dose of 18 Gy using 200-kVp x-rays. The lung function of the animals was measured every 2 weeks after irradiation with the breathing rate assay.

View Article and Find Full Text PDF

To achieve increased image acquisition speed or better image quality, several read-out methods for a matrix ionization chamber system have been investigated. In this device, which is applied for portal imaging in radiation therapy, 256 x 256 small liquid-filled ionization chambers are scanned by switching the polarizing voltage applied to rows of chambers. The ionization current of each column is measured by a separate amplifier.

View Article and Find Full Text PDF

On-line electronic portal imaging devices are beginning to come into clinical service in support of radiotherapy. A variety of technologies are being explored to provide real-time or near real-time images of patient anatomy within x-ray fields during treatment on linear accelerators. The availability of these devices makes it feasible to verify treatment portals with much greater frequency and clarity than with film.

View Article and Find Full Text PDF

In our institute an electronic portal imaging device (PID) has been developed and it recently became available for routine clinical practice. Images are available within 3 to 6 seconds after the start of irradiation; they are displayed on a video monitor next to the control console of the accelerator. The image quality is similar to the quality of images obtained with films.

View Article and Find Full Text PDF

Source strength measurements were performed for cesium-137 spherical sources of nine Selectron-LDR remote afterloading systems in The Netherlands. The mean reference air kerma rate of a set of sources was obtained from air kerma rate measurements in a phantom at a distance of about 5.5 cm from a large number (24 to 30) of sources.

View Article and Find Full Text PDF

Correct placement of radiation fields relative to patient anatomy is essential in radiotherapy in order to minimise serious side effects to reduce the probability of recurrence of the tumour. One way to determine patient setup accuracy is to analyse portal images obtained in the therapy beam distal to the patient. A field placement analysis (FPA) method has been developed for detailed evaluation of patient setup by comparing positions of corresponding radiation field edges in digitised simulator and portal images.

View Article and Find Full Text PDF