Publications by authors named "Mckiddie F"

Background: Patients with breast cancer undergoing biological therapy and/or chemotherapy perform multiple radionuclide angiography (RNA) or multigated acquisition (MUGA) scans to assess cardiotoxicity. The association between RNA imaging parameters and left ventricular (LV) ejection fraction (LVEF) remains unclear.

Objectives: This study aimed to extract and evaluate the association of several novel imaging biomarkers to detect changes in LVEF in patients with breast cancer undergoing chemotherapy.

View Article and Find Full Text PDF

High-dimensional radiomics features derived from pre-treatment positron emission tomography (PET) images offer prognostic insights for patients with head and neck squamous cell carcinoma (HNSCC). Using 124 PET radiomics features and clinical variables (age, sex, stage of cancer, site of cancer) from a cohort of 232 patients, we evaluated four survival models-penalized Cox model, random forest, gradient boosted model and support vector machine-to predict all-cause mortality (ACM), locoregional recurrence/residual disease (LR) and distant metastasis (DM) probability during 36, 24 and 24 months of follow-up, respectively. We developed models with five-fold cross-validation, selected the best-performing model for each outcome based on the concordance index (C-statistic) and the integrated Brier score (IBS) and validated them in an independent cohort of 102 patients.

View Article and Find Full Text PDF

. Accurate and reproducible tumor delineation on positron emission tomography (PET) images is required to validate predictive and prognostic models based on PET radiomic features. Manual segmentation of tumors is time-consuming whereas semi-automatic methods are easily implementable and inexpensive.

View Article and Find Full Text PDF

Background: Positron emission tomography (PET) images of head and neck squamous cell carcinoma (HNSCC) patients can assess the functional and biochemical processes at cellular levels. Therefore, PET radiomics-based prediction and prognostic models have the potentials to understand tumour heterogeneity and assist clinicians with diagnosis, prognosis and management of the disease. We conducted a systematic review of published modelling information to evaluate the usefulness of PET radiomics in the prediction and prognosis of HNSCC patients.

View Article and Find Full Text PDF

Radioactive iodine is a highly effective treatment for thyroid cancer and has now been used in clinical practice for more than 80 years. In general, the treatment is well tolerated. However, it can be logistically quite complex for patients due to the need to reduce iodine intake and achieve high levels of thyroid-stimulating hormone prior to treatment.

View Article and Find Full Text PDF

The Ionising Radiation (Medical Exposure) Regulations require employers to appoint suitable medical physics experts (MPE) for nuclear medicine services, and they also define the areas where MPEs are required to provide advice and specify matters that they must contribute towards. Applications for employer licences under IR(ME)R require employers to specify the level of MPE support available and if this is provided by onsite MPEs or remotely. Assessment of these applications by the Administration of Radioactive Substances Advisory Committee (ARSAC) has highlighted variability in the levels of MPE support being provided for similar services across the UK.

View Article and Find Full Text PDF

Objective: To explore differences in position emission tomography-computed tomography (PET-CT) service provision internationally to further understand the impact variation may have upon cancer services. To identify areas of further exploration for researchers and policymakers to optimize PET-CT services and improve the quality of cancer services.

Design: Comparative analysis using data based on pre-defined PET-CT service metrics from PET-CT stakeholders across seven countries.

View Article and Find Full Text PDF

Objectives: This study investigated the subcentimetre lesion detection gains of a Bayesian penalised likelihood reconstruction (BPLR) (Q.Clear, GE Healthcare, Milwaukee, USA) in PET/computed tomography (CT) phantom images and compares observer performance with ordered subset expectation maximisation (OSEM) reconstruction images (VUE Point HD, GE Healthcare).

Methods: Images were presented to three blinded experienced observers to identify lesions and assign confidence ratings.

View Article and Find Full Text PDF

Background Exercise-induced pulmonary hypertension is common in heart failure with preserved ejection fraction ( HF p EF ). We hypothesized that this could result in pericardial constraint and diastolic ventricular interaction in some patients during exercise. Methods and Results Contrast stress echocardiography was performed in 30 HF p EF patients, 17 hypertensive controls, and 17 normotensive controls (healthy).

View Article and Find Full Text PDF

Recently heart failure with preserved ejection fraction (HFpEF) has emerged as a huge epidemic. Increasing evidence shows the role of energy deficiency in the pathophysiology of HFpEF. In the current study, we hypothesize that the use of metabolic modulator perhexiline would correct myocardial energy deficiency and improve exercise capacity and diastolic abnormalities in patients with this syndrome.

View Article and Find Full Text PDF

DMSA imaging is carried out in nuclear medicine to assess the level of functional renal tissue in patients. This study investigated the use of an artificial neural network to perform diagnostic classification of these scans. Using the radiological report as the gold standard, the network was trained to classify DMSA scans as positive or negative for defects using a representative sample of 257 previously reported images.

View Article and Find Full Text PDF

Background: Cytotoxic chemotherapy remains the main systemic therapy for gastro-oesophageal adenocarcinoma, but resistance to chemotherapy is common, resulting in ineffective and often toxic treatment for patients. Predictive biomarkers for chemotherapy response would increase the probability of successful therapy, but none are currently recommended for clinical use. We used global gene expression profiling of tumour biopsies to identify novel predictive biomarkers for cytotoxic chemotherapy.

View Article and Find Full Text PDF

Background: Fluorine-18-labelled fluoroxdeoxyglucose (FDG) positron emission tomography (PET) has been used to evaluate atherosclerotic plaque metabolic activity, and through its uptake by macrophages is believed to have the potential to identify vulnerable plaques. The aims were to compare FDG uptake in carotid plaques from patients who had sustained a recent thromboembolic cerebrovascular event with that in femoral artery plaques from patients with leg ischaemia, and to correlate FDG uptake with the proportion of M1 and M2 macrophages present.

Methods: Consecutive patients who had carotid endarterectomy for symptomatic, significant carotid stenosis and patients with severe leg ischaemia and significant stenosis of the common femoral artery underwent FDG-PET and histological plaque analysis.

View Article and Find Full Text PDF

TauroH-23-(Se) selena-25-homocholic acid retention values are used in the diagnosis of bile acid malabsorption. The standard method for measuring values is with an uncollimated gamma camera, which can create some logistic difficulties, with other background sources of activity, which are irrelevant when a collimator is used, becoming significant. In this study we compare the retention values obtained with a collimated and an uncollimated gamma camera in phantoms and in 23 patients.

View Article and Find Full Text PDF

Dimercaptosuccinic acid imaging is the 'gold standard' for the detection of cortical defects and diagnosis of scarring of the kidneys. The Siemens planar processing package, which implements adaptive noise reduction using the Pixon algorithm, is designed to allow a reduction in image noise, enabling improved image quality and reduced acquisition time/injected activity. This study aimed to establish the level of improvement in image quality achievable using this algorithm.

View Article and Find Full Text PDF

Radionuclide imaging of cardiac function represents a number of well-validated techniques for accurate determination of right (RV) and left ventricular (LV) ejection fraction (EF) and LV volumes. These first European guidelines give recommendations for how and when to use first-pass and equilibrium radionuclide ventriculography, gated myocardial perfusion scintigraphy, gated PET, and studies with non-imaging devices for the evaluation of cardiac function. The items covered are presented in 11 sections: clinical indications, radiopharmaceuticals and dosimetry, study acquisition, RV EF, LV EF, LV volumes, LV regional function, LV diastolic function, reports and image display and reference values from the literature of RVEF, LVEF and LV volumes.

View Article and Find Full Text PDF

The European procedural guidelines for radionuclide imaging of myocardial perfusion and viability are presented in 13 sections covering patient information, radiopharmaceuticals, injected activities and dosimetry, stress tests, imaging protocols and acquisition, quality control and reconstruction methods, gated studies and attenuation-scatter compensation, data analysis, reports and image display, and positron emission tomography. If the specific recommendations given could not be based on evidence from original, scientific studies, we tried to express this state-of-art. The guidelines are designed to assist in the practice of performing, interpreting and reporting myocardial perfusion SPET.

View Article and Find Full Text PDF

Background: The aim of this study was to examine the quality of nitrogen 13-labeled ammonia (NH(3)) perfusion data from coincidence-capable gamma camera positron emission tomography (GC-PET) systems compared with that from full-ring positron emission tomography (FR-PET).

Methods And Results: The performance parameters of the GC-PET system were examined and found adequate for imaging at the activity levels used clinically. We studied 15 patients who underwent stress and rest N-13-labeled NH(3) perfusion imaging on FR-PET and GC-PET systems.

View Article and Find Full Text PDF

The purpose of this study was to compare the performance of automatic detection of coronary artery disease (CAD) with that of expert observers. A male and female normal image template was constructed from normal stress technetium-99m single photon emission computed tomography (SPECT) studies. Mean and standard deviation images for each sex were created by registering normal studies to a standard shape and position.

View Article and Find Full Text PDF

Aim: The aim of this study was to use statistical parametric mapping (SPM) to investigate differences in the regional cerebral blood flow (rCBF) of decompression illness (DCI) and non-diving control subjects.

Methods: Twenty DCI subjects were imaged using 99Tcm hexamethylproplylene amine oxime (HMPAO) single photon emission tomography (SPET) within days of their incident of DCI, and on a second occasion between 2 and 27 months after their DCI event. SPM was used to make a comparison between decompression illness studies and a second group of non-diving control studies for both early and late imaging of DCI.

View Article and Find Full Text PDF