• Updated breast cancer adjuvant radiotherapy treatment protocols resulted in a reduction of staff time (linac and non-linac) and overall resource costs. • The introduction of ultrahypofractionated 26Gy/5 radiotherapy resulted in the greatest saving of resource costs, €47,489, and staff time, 13,820 min. • Expanded use of IMN radiotherapy resulted in the largest increase in resource costs, €7,612, and staff time, 11,345 min.
View Article and Find Full Text PDFPurpose: This study quantifies intrafraction motion in surface-guided radiation therapy (SGRT) for breast cancer and considers the need for individualized intrafraction motion measures when calculating planning target volume (PTV) margins.
Methods And Materials: SGRT was used to assess intrafraction motion in consecutive patients according to (1) site irradiated (whole-breast/chest wall vs whole-breast/chest wall + regional lymph nodes) and (2) the use of deep inspiration breath hold versus free breathing. Intrafraction motion variation was evaluated throughout the treatment course for all cases.
Background: The Relative Biological Effectiveness (RBE) of kilovoltage photon beams has been previously investigated in vitro and in silico using analytical methods. The estimated values range from 1.03 to 1.
View Article and Find Full Text PDFPurpose: Accepted conformity metrics in stereotactic ablative body radiotherapy (SABR) have significant limitations. This work aimed to develop a spatial assessment methodology that improves and automates checks of dose prescription and dose gradient from planning target volume (PTV) edge.
Methods: A Python-based script was developed to determine linear distances from the PTV edge to specified isodose, every 15 degrees on all axial slices and along the central axis in the coronal plane.
Background And Purpose: Hypo-fractionated lung Stereotactic Ablative Body Radiotherapy (SABR) has often been avoided when tumours are close to the chest wall. Our strategic objective was the reduction of fraction number, while maintaining target biological effective dose coverage without increasing chest wall toxicity (CWT) predictors.
Materials And Methods: Twenty previously treated lung SABR patients were stratified into four cohorts according to distance from PTV to the chest wall, <1 cm, <0.
Kilovoltage radiotherapy dose calculations are generally performed with manual point dose calculations based on water dosimetry. Tissue heterogeneities, irregular surfaces, and introduction of lead cutouts for treatment are either not taken into account or crudely approximated in manual calculations. Full Monte Carlo (MC) simulations can account for these limitations but require a validated treatment unit model, accurately segmented patient tissues and a treatment planning interface (TPI) to facilitate the simulation setup and result analysis.
View Article and Find Full Text PDFIrradiation of the tumour site during treatment for cancer with external-beam ionising radiation results in a complex and dynamic series of effects in both the tumour itself and the normal tissue which surrounds it. The development of a spectral model of the effect of each exposure and interaction mode between these tissues would enable label free assessment of the effect of radiotherapeutic treatment in practice. In this study Fourier transform Infrared microspectroscopic imaging was employed to analyse an model of radiotherapeutic treatment for prostate cancer, in which a normal cell line (PNT1A) was exposed to low-dose X-ray radiation from the scattered treatment beam, and also to irradiated cell culture medium (ICCM) from a cancer cell line exposed to a treatment relevant dose (2 Gy).
View Article and Find Full Text PDFPurpose: The purpose of this study was to evaluate the interobserver variability in the contouring of the gross tumor volume (GTV) on magnetic resonance (MR) imaging and computed tomography (CT) for colorectal liver metastases in the setting of SABR.
Methods And Materials: Three expert radiation oncologists contoured 10 GTV volumes on 3 MR imaging sequences and on the CT image data set. Three metrics were chosen to evaluate the interobserver variability: the conformity index, the DICE coefficient, and the maximum Hausdorff distance (HDmax).
On Friday, May 14, 2021, the Health Service Executive, the organization providing public health services in the Republic of Ireland, was the victim of a significant cyberattack on its information technology systems. All systems were subsequently shut down to prevent further damage and to allow cybersecurity experts to investigate the attack. As a result, oncology services were severely disrupted, with the cessation of radiation therapy treatments in all public radiation therapy departments.
View Article and Find Full Text PDFOn May 14, 2021, the Health Service Executive (HSE) of Ireland experienced a major ransomware cyberattack. The HSE initially took down all of its information technology systems to protect its core systems. All Internet connections within the HSE were unavailable from 7 am for approximetely three weeks which had a major effect on the radiation oncology service nationally within the public service.
View Article and Find Full Text PDFAims: To retrospectively evaluate the quality of fit of 3D printed bolus over four different treatment sites to determine whether certain sites favor a 3D printed approach and if the quality of fit changes over the course of treatment.
Materials And Methods: A retrospective analysis of the first 60 cases treated using 3D printed bolus in our radiotherapy center was undertaken. All boluses were printed using flexible thermoplastic polyurethane (TPU) material.
The quest for the discovery and validation of radiosensitivity biomarkers is ongoing and while conventional bioassays are well established as biomarkers, molecular advances have unveiled new emerging biomarkers. Herein, we present the validation of a new 4-gene signature panel of CDKN1, FDXR, SESN1 and PCNA previously reported to be radiation-responsive genes, using the conventional G2 chromosomal radiosensitivity assay. Radiation-induced G2 chromosomal radiosensitivity at 0.
View Article and Find Full Text PDFLow gain avalanche detectors can measure charged particle fluences with high speed and spatial precision, and are a promising technology for radiation monitoring and dosimetry. A detector has been tested in a medical linac where single particles were observed with a time resolution of 50 ps. The integrated response is similar to a standard ionising chamber but with a spatial precision twenty times finer, and a temporal precision over 100 million times better, with the capability to measure the charge deposited by a single linac pulse.
View Article and Find Full Text PDFPurpose: Radiation therapy plans are assessed using dose volume metrics derived from clinical toxicity and outcome data. In this study, plans for patients with locally advanced non-small cell lung cancer (LA-NSCLC) are examined in the context of the implementation of the Acuros XB (AXB) dose calculation algorithm focussing on the impact on common metrics.
Methods: Volumetric modulated arc therapy (VMAT) plans were generated for twenty patients, using the Analytical Anisotropic Algorithm (AAA) and recalculated with AXB for both dose to water (D) and dose to medium (D).
The Irish Association of Physicists in Medicine (IAPM) is an association of medical physicists in Ireland. The IAPM was founded in 2010 with the merger of the Association of Physical Scientists in Medicine (APSM) and the Irish Radiotherapy Physics Group (IRPG). The 10th Annual Scientific Meeting of the IAPM was held in Dublin on 23rd March 2019.
View Article and Find Full Text PDFGenetic and epigenetic profile changes associated with individual radiation sensitivity are well documented and have led to enhanced understanding of the mechanisms of the radiation-induced DNA damage response. However, the search continues to identify reliable biomarkers of individual radiation sensitivity. Herein, we report on a multi-biomarker approach using traditional cytogenetic biomarkers, DNA damage biomarkers and transcriptional microRNA (miR) biomarkers coupled with their potential gene targets to identify radiosensitivity in ataxia-telangiectasia mutated (ATM)-deficient lymphoblastoid cell lines (LCL); ATM-proficient cell lines were used as controls.
View Article and Find Full Text PDFPositive behavioral support (PBS) employs applied behavioral analysis to enhance the quality of life of people who behave in challenging ways. PBS builds on the straightforward and intuitively appealing notion that if people know how to control their environments, they will have less need to behave in challenging ways. Accordingly, PBS focuses on the perspective of those who have behavioral issues, and assesses success reduction in incidences of challenging behaviors.
View Article and Find Full Text PDFOn 5 December 2013 the European Council promulgated Directive 2013/59/EURATOM. This Directive is important for Medical Physicists and Medical Physics Experts as it puts the profession on solid foundations and describes it more comprehensively. Much commentary regarding the role and competences has been developed in the context of the European Commission project "European Guidelines on the Medical Physics Expert" published as Radiation Protection Report RP174.
View Article and Find Full Text PDFIt is now well accepted that radiation induced bystander effects can occur in cells exposed to media from irradiated cells. The aim of this study was to follow the bystander cells in real time following addition of media from irradiated cells and to determine the effect of inhibiting these signals. A human keratinocyte cell line, HaCaT cells, was irradiated (0.
View Article and Find Full Text PDFPurpose: Liquid biopsies are a potentially rich store of biochemical information that can be linked to an individual's response to therapeutic treatments, including radiotherapy, and which may ultimately play a role in the individualization of treatment regimens. Peripheral blood mononuclear cells (PBMCs) can be used not only for the biochemical profiling of the individual, but also, being living cells, can provide insights into the individuals response to ionizing radiation exposure.
Materials And Methods: The present study attempts to link the biochemical profile of lymphocytes within PBMCs obtained through Raman spectroscopy to in vitro measures of low-dose (<0.
Treatment outcomes in locally advanced non-small cell lung cancer (NSCLC) to date have been poor, with normal tissue toxicity often limiting the dose that can be delivered to the tumor. Treatment intensification in NSCLC via targeted dose escalation with modern delivery techniques may offer the potential for a significant increase in tumor control probability (TCP) without a clinically significant increase in organ-at-risk (OAR) toxicity. In this planning study, 20 patients were re-planned with a volumetric modulated arc therapy (VMAT) and an inhomogeneous dose distribution with iteratively escalated doses to the gross tumor volume (iGTV) (composite GTV across multiple 4-dimensional computed tomography [4DCT] phases) in a series of 20 fraction regimes.
View Article and Find Full Text PDFMultileaf collimators (MLCs) need to be characterized accurately in treatment planning systems to facilitate accurate intensity-modulated radiation therapy (IMRT) and volumetric-modulated arc therapy (VMAT). The aim of this study was to examine the use of MapCHECK 2 and ArcCHECK diode arrays for optimizing MLC parameters in Monaco X-ray voxel Monte Carlo (XVMC) dose calculation algorithm. A series of radiation test beams designed to evaluate MLC model parameters were delivered to MapCHECK 2, ArcCHECK, and EBT3 Gafchromic film for comparison.
View Article and Find Full Text PDFHypofractionated radiation therapy (RT) regimes in non-small cell lung cancer (NSCLC) have become increasingly popular with a number of international trials currently underway. The majority of the dose-volume-constraints (DVCs) published in the literature refer to conventional 2Gy per fraction deliveries. Here relevant organs-at-risk (OARs) are identified and available dose-volume constraint data discussed and summarised for moderately hypofractionated NSCLC regimes.
View Article and Find Full Text PDFPurpose: In this study, a 3D phase correlation algorithm was investigated to test feasibility for use in determining the anatomical changes that occur throughout a patient's radiotherapy treatment. The algorithm determines the transformations between two image volumes through analysis in the Fourier domain and has not previously been used in radiotherapy for 3D registration of CT and CBCT volumes.
Methods: Various known transformations were applied to a patient's prostate CT image volume to create 12 different test cases.
Purpose: The use of radiotherapy fields smaller than 3 cm in diameter has resulted in the need for accurate detector correction factors for small field dosimetry. However, published factors do not always agree and errors introduced by biased reference detectors, inaccurate Monte Carlo models, or experimental errors can be difficult to distinguish. The aim of this study was to provide a robust set of detector-correction factors for a range of detectors using numerical, empirical, and semiempirical techniques under the same conditions and to examine the consistency of these factors between techniques.
View Article and Find Full Text PDF