Objectives: We report on a rare but severe complication of adenosine use in a child with reentry tachycardia.
Methods And Results: Treatment with adenosine, which is the standard medical therapy of atrioventricular reentry tachycardia, led to the development of an irregular wide complex tachycardia, caused by rapid ventricular response to atrial fibrillation. The girl was finally stabilized with electrical cardioversion.
Study Objective: To determine and interpret the changes in preload, afterload, and cardiac function in the different phases of robot-assisted laparoscopic prostatectomy.
Design: Prospective, observational monocenter study.
Setting: Operating room at a university hospital.
Objectives: Transesophageal echocardiography has become a standard tool for evaluating left ventricular function during cardiac surgery. However, the image quality varies widely between patients and examinations. The aim of this study was to investigate the influence of the image quality on 5 commonly used 2-dimensional methods.
View Article and Find Full Text PDFBackground: Three-dimensional transesophageal echocardiography (3DTEE) has been demonstrated to provide more accurate information than two-dimensional transesophageal echocardiography (2DTEE) in the localization of mitral valve prolapse (MVP). However, most studies have been single-rater studies. Few results were tested for inter-observer variability with a single second rater.
View Article and Find Full Text PDFBackground: Three-dimensional (3D) transesophageal echocardiography (TEE) has been claimed to provide more information than two-dimensional (2D) TEE in the localization of mitral valve prolapse (MVP). However, most studies have been performed by experts in echocardiography, without accounting for differences in training or expertise. This multicenter study was designed to assess the differences between experts and inexperienced echocardiographers in localizing MVP and ruptured chordae tendineae using 2D and real-time 3D TEE.
View Article and Find Full Text PDFTransesophageal echocardiography is recommended to monitor left ventricular (LV) size and function in various operations. Generally, two-dimensional (2D) methods are applied intraoperatively. The aim of this study was to compare the accuracy and feasibility of 6 commonly used 2D methods to assess LV function during surgery.
View Article and Find Full Text PDFBackground: Successful surgical repair of a regurgitant mitral valve (MV) is dependent on a comprehensive assessment of its complex anatomy. Although there is limited evidence of the feasibility and accuracy of intraoperative real-time 3-dimensional transesophageal echocardiography (RT3DTEE) in MV surgery, its use is increasing worldwide. We designed this prospective observational study of patients with mitral regurgitation to test initial findings on the accuracy of RT3DTEE images in the diagnosis of MV prolapse and chordal rupture relative to 2D imaging and to assess the potential of RT3DTEE for visualizing leaflet clefts.
View Article and Find Full Text PDFBackground: Three-dimensional (3D) transesophageal echocardiography (TEE) enables the determination of the vena contracta area (VCA), which is an approved parameter to quantify mitral regurgitation (MR). The aim of this study was to determine the VCA in the operative setting and to compare it to alternative 3D and standard 2D methods, with respect to different etiologies of MR.
Methods: MR in 56 consecutive patients undergoing cardiac surgery was evaluated using 2D and 3D TEE.
Background: The impact of mitral valve surgery on left ventricular outflow tract (LVOT) dimensions is unclear. Real-time three-dimensional transesophageal echocardiography permits excellent visualization of the LVOT and might improve standard two-dimensional measurements. In this study, LVOT area and shape were assessed before and after mitral valve surgery.
View Article and Find Full Text PDF