Publications by authors named "Maximiano Lombardo Torre"

Persistent rotational instability after anterior cruciate ligament reconstruction is a relatively common postoperative complication, typically associated with graft verticalization due to improper femoral tunnel placement, especially with classic transtibial femoral tunnel techniques. This article describes a technique designed to reorient a verticalized anterior cruciate ligament graft at its femoral insertion to a more anatomic position in the coronal and sagittal planes, aiming to restore knee stability without the need for a complete revision operation. Additionally, a lateral extra-articular tenodesis with fascia lata is added to reinforce rotational stability.

View Article and Find Full Text PDF

Purpose: The purpose of this study was to evaluate practice patterns of a single surgeon with respect to meniscectomy and meniscal repair over a 20-year period at a single institution.

Methods: A cross-sectional descriptive study was carried out by reviewing the surgical data from the past 20 years (2002-2021) of patients who underwent arthroscopic primary meniscal surgery. Age, sex, knee and meniscus affected, morphology of the meniscal tear, meniscal radial location, location on the axial plane, tissue quality, and associated injuries were recorded.

View Article and Find Full Text PDF

Lateral collateral ligament (LC) injuries that go unnoticed when associated with an anterior cruciate ligament (ACL) tear can increase stress forces on the ACL graft causing its failure. Furthermore, it is a main stabilizer to varus stress and external rotation. On the other hand, the reinforcement of anterolateral structures during ACL reconstruction has regained popularity in recent years, because evidence has shown that it increases the control of rotational laxity and decreases ACL graft failures, especially in revision surgery.

View Article and Find Full Text PDF

A technique for augmentation of the anterior cruciate ligament (ACL) with hamstring graft and lateral extra-articular tenodesis is presented. The patient is positioned supine with the knee flexed 90°. First, intra-articular injuries are addressed arthroscopically, and then autologous hamstring tendons are harvested and measured; the present technique is a resource for cases with a very small graft diameter (less than 8 mm), due to thin tendons or to tendon breakage, even after tripling the hamstring graft, which is prepared using a facia lata strip long enough to fit the lengths of the femoral tunnel, the anterior cruciate ligament graft, and the tibial tunnel.

View Article and Find Full Text PDF

Background: In ACL repair, full-length single-diameter tunnels facilitate anatomic femoral fixation with suspensory devices, especially with outside-in techniques, and are required after accidental cortical perforation. With tunnel diameters over 6 mm, fixation resistance using regular suspensory devices may not suffice. Oversized cortical footprint devices could be a solution to guarantee fixation performance in larger tunnel diameters.

View Article and Find Full Text PDF

Introduction: Surgical lengthening and angular correction of the limbs are an option for treating the orthopedic clinical manifestations in patients with achondroplasia. This study assesses a staged limb lengthening protocol, performing simultaneous bilateral lengthening of the femur and tibia (stage I [S1]), and humeral lengthening (stage II [S2]).

Materials And Methods: Twenty-one achondroplastic patients were included in this study, and 106 segments (34 femurs, 34 tibias and 38 humeri) were lengthened.

View Article and Find Full Text PDF

Introduction: Simultaneous avulsion fractures of the insertion of both cruciate ligaments of the knee are extremely uncommon lesions and their treatment remains difficult. The purpose of this paper is to show an arthroscopic repair technique of simultaneous tibial avulsion fracture of both cruciate ligaments of the knee such by using an adjustable length suspension device.

Case Report: A 25-year-oldmale patient was treated by arthroscopic reduction and fixation of both bony avulsion of cruciate ligaments of the knee with a sliding and adjustable length suspension device (ZipTight, Biomet, Warsaw, IN, USA).

View Article and Find Full Text PDF
Article Synopsis
  • The study aimed to evaluate the impact of suture cutout on the failure mechanics of repaired posterior meniscal roots using different suture shapes in an early post-operative setting.
  • Twenty porcine menisci were tested with two types of sutures (thread and tape) under cyclic loading and load-to-failure conditions, measuring key factors like stiffness and ultimate failure load.
  • Results showed no significant cutout progression or displacement differences during cyclic tests, but tape sutures demonstrated a higher ultimate load before failure compared to thread sutures.
View Article and Find Full Text PDF

A technique for posterior cruciate ligament reconstruction is presented. Autologous hamstring tendons are selected as a graft. An interference screw is used for femoral fixation.

View Article and Find Full Text PDF