Knee Surg Sports Traumatol Arthrosc
August 2014
Purpose: Mobile bearing (MB) knee prostheses were designed to improve the performances of the total knee arthroplasties (TKA). The clinical superiority of MB prosthesis compared to its fixed bearing counterpart has remained elusive. This study prospectively evaluates the cumulative survivorship, clinical, radiographic results, and complications of a large series of MB TKAs in relation to patient age, sex, severity of arthritis, and patellar resurfacing.
View Article and Find Full Text PDFThe goal of this study was to analyze the clinical and radiographic results and the survival rate of a series of rotating-hinge implants used for revision total knee arthroplasties in mild and severe instability. Between December 1991 and June 2004, fifty-three revision total knee arthroplasties were performed using the Endo-Modell (Waldemar LINK GmbH and Co, Hamburg, Germany) rotating-hinge prosthesis; 7 (13.2%) patients underwent partial revision of a previous Endo-Modell.
View Article and Find Full Text PDFBackground: The superiority of mobile-bearing total knee arthroplasty implants over fixed-bearing implants, or vice versa, is still debated.
Methods: A series of patients with similar clinical and radiographic characteristics were treated consecutively with 100 fixed-bearing followed by 100 rotating-platform implants. Patients underwent prospective clinical and radiographic evaluation.
The purpose of this cadaveric study was to evaluate the primary stability of a membrane (resorbable polyglactin-910/poly-p-dioxanone) for autologous chondrocyte implantation (ACI) inserted by press-fit into defects in the femoral head and acetabulum. The stability of the membrane was evaluated after implantation in a cartilage defect on both sides of the joint in 12 hips in six cadavers. The hip was manually put through a full range of motion for 50 cycles after each lesion had been created and filled, starting with the acetabulum.
View Article and Find Full Text PDFRotating hinge knee prostheses have been developed as an advancement of the fixed hinge models. Some authors suggest that this type of prosthesis is associated with a greater risk of aseptic loosening because of the increased stresses to the bone-prosthesis interface; therefore, they are scarcely used as primary implants. The current authors evaluated of a series of 98 rotating hinge knee arthroplasties Endo-Modell (Waldemar LINK GmbH and Co, Hamburg, Germany) implanted for knee osteoarthritis.
View Article and Find Full Text PDFRotating-hinge knee implants are used for revision total knee arthroplasty in patients with severe ligament instability and bone loss. This study evaluated the outcomes of a series of rotating-hinge knees. Thirty-one NexGen Rotating Hinge Knees (Zimmer, Warsaw, Indiana) were implanted in 29 patients (2 bilateral), with an average age of 72.
View Article and Find Full Text PDFCongenital permanent dislocation of the patella is a rare disorder of the knee joint in which the patella is permanently displaced, even in extension and is fixed on the lateral aspect of the femoral condyle. The dislocation is irreducible without surgical techniques. This rare condition is usually detected within the first decade of life, because of inability of active extension in the knee and impaired ability during walking.
View Article and Find Full Text PDFThe aim is to perform the assessment of a modular cementless acetabular cup with a tapered internal design for all bearing couplings. In 190 unselected consecutive patients, 207 total hip arthroplasties were implanted. The implants were clinically and radiographically evaluated.
View Article and Find Full Text PDFPurpose: To compare the effectiveness of simple arthroscopic debridement versus arthroscopic autologous chondrocyte transplantation (ACT) for the treatment of hip chondral lesions.
Methods: We carried out a controlled retrospective study of 30 patients affected by a post-traumatic hip chondropathy of the third or fourth degree, according to the Outerbridge classification, measuring 2 cm² in area or more. Of these patients, 15 underwent arthroscopic ACT, whereas the other 15 underwent arthroscopic debridement.
Dislocation is a common and important complication of total hip arthroplasty (THA). Larger femoral heads may reduce the risk of dislocation and improve the range of movement. The aim of this study was to compare the relative risk (RR) of dislocation during the first year after THA between implants with 28 mm and 36 mm femoral heads.
View Article and Find Full Text PDFThis paper discusses a sciatic nerve palsy developed after a right total hip revision with a Burch-Schneider metal cage. A sciatalgic nerve pain appeared after surgery, while the palsy developed in about fifteen days. An electromyography showed the delay of the nerve impulse gluteal level.
View Article and Find Full Text PDFIrreducibility of the knee following complete dislocation is a rare event determined by the interposition of various capsulo-ligamentous structures in the joint space. Such cases often require urgent surgical treatment. We report the case of a healthy 70-year-old man with a sprain of the left knee that occurred after a sports trauma.
View Article and Find Full Text PDFPurpose: The purpose of this study is the evaluation of the differences and, eventually, of the advantages or disadvantages of manual formulations with respect to industrial ones.
Methods: Medical-grade bone cements (Palacos R® and Palacos LV®), based on poly-methyl methacrylate (PMMA) and used clinically in several cemented prosthetic devices were manually enriched with gentamicin sulphate during preparation and then compared with a commercially-available, antibiotic-loaded cement (Palacos R+G®) by means of an in vitro antibacterial test (inhibition zone evaluation). The purpose of this study was to evaluate the differences and advantages or disadvantages, if any, of manual formulations compared to commercial ones.
Infections in orthopaedic surgery are a serious issue. Antibiotic-loaded bone cement was developed for the treatment of infected joint arthroplasties and for prophylaxes in total joint replacement in selected cases. Despite the widespread use of the antibiotic-loaded bone cement in orthopedics, many issues are still unclear or controversial: bacterial adhesion and antibiotic resistance, modification of mechanical properties which follows the addition of the antibiotic, factors influencing the release of the antibiotic from the cement and the role of the surface, the method for mixing the cement and the antibiotic, the choice and the effectiveness of the antibiotic, the combination of two or more antibiotics, and the toxicity.
View Article and Find Full Text PDF