Concentration polarization (CP) is an important issue in forward osmosis (FO) processes and it is believed that the coupled effect of dilutive internal CP (DICP) and concentrative external CP (CECP) limits FO flux. The objective of this study was to distinguish individual contribution of different types of DICP and CECP via modeling and to validate it by pilot studies. The influence of DICP/CECP on FO flux has been investigated in this study.
View Article and Find Full Text PDFThe objective of this pilot study was to investigate the operational conditions of newly developed MBR modules for water reclamation under tropical conditions. MUDC-620A MBR modules with hollow fibre PVDF membranes from Asahi-Kasei Chemicals were used in the study. The pilot plant with capacity of 50 m(3)/d was operated continuously (24-hour) over four months on site of Ulu Pandan Water Reclamation Plant (UPWRP) in Singapore.
View Article and Find Full Text PDFThe objective of this work was to conduct treatability studies on rinse wastewater from process lines of a typical nickel-plating plant for reuse. The study comprised of three steps: (1) a plant process review and the treatability of different combinations of simulated spent rinses in the laboratory; (2) a variability monitoring of a combined rinse at the plant and a treatability study on a combined rinse in the laboratory; (3) a pilot study for reclamation of the combined rinse on site. The study established an optimum dual membrane ultrafiltration (UF)/reverse osmosis (RO) process for treating a combined liquor of spent alkaline, acidic and nickel-plating rinses which resulted in a treated water of a quality suitable for reuse as substitute for town water for the purpose of rinsing.
View Article and Find Full Text PDF