Publications by authors named "Mattijs Koeberg"

In this follow-up study the collaboration between two research groups from the USA and the Netherlands was continued to expand the framework of chemical attribution for the homemade explosive erythritol tetranitrate (ETN). Isotope ratio mass spectrometry (IRMS) analysis was performed to predict possible links between ETN samples and its precursors. Carbon, nitrogen, hydrogen and oxygen isotope ratios were determined for a wide variety of precursor sources and for ETN samples that were prepared with selected precursors.

View Article and Find Full Text PDF

High volume screening of parcels with the aim to trace the illegal distribution and selling of fireworks using postal services is challenging. Inspection services have limited manpower and means to perform extensive visual inspection. In this study, the presence of solid pyrotechnic residues collected from cardboard shipping parcels containing fireworks was investigated for direct in-field chemical detection.

View Article and Find Full Text PDF

Erythritol tetranitrate (ETN) was prepared independently by two research groups from the USA and the Netherlands. The partially nitrated impurities present in ETN were studied using liquid chromatography-mass spectrometry to address the ultimate challenge in forensic explosives investigations, i.e.

View Article and Find Full Text PDF

To continue to assist law enforcement agencies in counteracting the illegal use of fireworks new forensic methods have to be developed. In the Netherlands, many incidents involve powerful flash bangers mainly due to irresponsible behavior and misuse for criminal activities. Obtaining tactical information for differentiation of these flash bangers is of high priority in forensic casework.

View Article and Find Full Text PDF

This study builds on the multicomponent analysis strategy for flash bangers which was previously introduced and where a representative sample set has been collected of a certain type of flash bangers. To expand the forensic strategy, elemental analysis of the plastic caps which are present in these items was performed. Both x-ray fluorescence (XRF) and laser ablation-inductively coupled plasma-mass spectrometry (LA-ICP-MS) analysis was performed to explore the possibilities for differentiation.

View Article and Find Full Text PDF

Liquid Extraction Surface Analysis (LESA) is a new, high throughput tool for ambient mass spectrometry. A solvent droplet is deposited from a pipette tip onto a surface and maintains contact with both the surface and the pipette tip for a few seconds before being re-aspirated. The technique is particularly suited to the analysis of trace materials on surfaces due to its high sensitivity and low volume of sample removal.

View Article and Find Full Text PDF

Studying links between triacetone triperoxide (TATP) samples from crime scenes and suspects can assist in criminal investigations. Isotope ratio mass spectrometry (IRMS) and gas chromatography (GC)-IRMS were used to measure the isotopic compositions of TATP and its precursors acetone and hydrogen peroxide. In total, 31 TATP samples were synthesized with different raw material combinations and reaction conditions.

View Article and Find Full Text PDF

Ammonium nitrate (AN) is frequently encountered in explosives in forensic casework. It is widely available as fertilizer and easy to implement in explosive devices, for example by mixing it with a fuel. Forensic profiling methods to determine whether material found on a crime scene and material retrieved from a suspect arise from the same source are becoming increasingly important.

View Article and Find Full Text PDF

In this work, a reliable and robust vacuum-outlet gas chromatography-mass spectrometry (GC-MS) method is introduced for the identification and quantification of impurities in trinitrotoluene (TNT). Vacuum-outlet GC-MS allows for short analysis times; the analysis of impurities in TNT was performed in 4min. This study shows that impurity profiling of TNT can be used to investigate relations between TNT samples encountered in forensic casework.

View Article and Find Full Text PDF

After an explosion of pentaerythritol tetranitrate (PETN), its degradation products pentaerythritol trinitrate (PETriN), dinitrate (PEDiN) and mononitrate (PEMN) were detected using liquid chromatography-atmospheric-pressure chemical-ionization-mass spectrometry (LC-APCI-MS). Discrimination between post-explosion and naturally degraded PETN could be achieved based on the relative amounts of the degradation products. This information can be used as evidence when investigating a possible relationship between a suspect and a post-explosion crime scene.

View Article and Find Full Text PDF

An LTQ-Orbitrap FTMS is a new (hybrid) mass spectrometric (MS) analyzer. It allows for the acquisition of full scan MS(n) (n-stage fragmentations, n=1-n) spectra with the linear ion trap detector (LTQ) at high speed and/or with the Fourier Transform-detector (Orbitrap) with ultra high mass resolution (>60,000 at m/z<400amu) and high mass accuracy (≤1ppm with internal calibration). In addition it may be coupled with liquid chromatography (LC) with photo diode array (PDA) detection.

View Article and Find Full Text PDF

Pentaerythritol tetranitrate (PETN) and its degradation products are analyzed to discriminate between residues originating from PETN explosions and residues obtained under other circumstances, such as natural degradation on textile, or after handling intact PETN. The degradation products observed in post-explosion samples were identified using liquid chromatography-mass spectrometry as the less-nitrated analogues of PETN: pentaerythritol trinitrate (PETriN), pentaerythritol dinitrate (PEDiN) and pentaerythritol mononitrate (PEMN). Significant levels of these degradation products were observed in post-explosion samples, whereas only very low levels were detected in a variety of intact PETN samples and naturally degraded PETN.

View Article and Find Full Text PDF

The results of isotope ratio mass spectrometry (IRMS) on hexamethylene triperoxide diamine (HMTD) and its precursor hexamethylenetetramine (hexamine) is presented. HMTD was prepared from hexamine using several different sources of hexamine under both controlled laboratory conditions and in field experiments that represent the less controlled conditions that are likely to be observed in forensic casework scenarios. Precursor and product carbon isotope δ values consistently fit a linear relationship regardless of precursor or conditions.

View Article and Find Full Text PDF

Post explosion residues (PER) are residues from pyrotechnic compositions or explosives that are generated during an explosion. In the recent past SEM/EDX was used several times to analyze PER from pyrotechnic compositions. The results from these studies suggest that there might be a difference in morphology and composition of pyrotechnic residues formed at different levels of confinement.

View Article and Find Full Text PDF

Terahertz time-domain spectroscopy has been used to study the dielectric relaxation of pure 4'-n-pentyl-4-cyanobiphenyl (5CB) liquid crystal (LC) and its mixtures with 10 mum SiO2 particles in the frequency range 0.2-2 THz. For the pure sample, we find that spatial inhomogeneities consisting of oriented domains, comparable in size to our probe area (~1 mm(2)), cause a large scatter in the measured dielectric function, due to varying contributions from the ordinary and extraordinary components.

View Article and Find Full Text PDF

This paper describes the strategy toward novel monodisperse, well-defined, star-shaped oligofluorenes with a central truxene core and from monofluorene to quaterfluorene arms. Introduction of solubilizing n-hexyl groups at both fluorene and truxene moieties results in highly soluble, intrinsically two-dimensional nanosized macromolecules T1-T4. The radius for the largest oligomer of ca.

View Article and Find Full Text PDF