Publications by authors named "Matthias Mertmann"

(1) Background: After more than a decade since their first description, Inadvertent Tooth Movements (ITMs) remain an adverse effect of orthodontic retainers without a clear etiology. To further investigate the link between ITMs and the mechanical properties of different retainers, the response upon vertical loading was compared in three retainer types (two stainless steel and one nickel-titanium). The influence of different reference teeth was also considered.

View Article and Find Full Text PDF

The aim of this study was to investigate the load deflection characteristics of Gummetal wires in comparison to nickel-titanium (NiTi) wires. Four different NiTi wires and one Gummetal archwire were analyzed in two dimensions (0.014″ (0.

View Article and Find Full Text PDF

The Robot Orthodontic Measurement and Simulation System (ROSS) is a novel biomechanical, dynamic, self-regulating setup for the simulation of tooth movement. The intrusion of the front teeth with forces greater than 0.5 N poses a risk for orthodontic-induced inflammatory root resorption (OIIRR).

View Article and Find Full Text PDF

The shape of superelastic Nickel-Titanium (NiTi) archwires can be adjusted with thermal treatments using devices such as the Memory-Maker (Forestadent), which potentially affects their mechanical properties. The effect of such treatments on these mechanical properties was simulated by means of a laboratory furnace. Fourteen commercially available NiTi wires (0.

View Article and Find Full Text PDF

The purpose was to determine the effect of different environments (artificial saliva, human saliva, distilled water, dry storage) on frictional forces between various tribological systems made from self-ligating brackets in combination with stainless-steel wires (dimensions: 0.016″×0.022″, 0.

View Article and Find Full Text PDF

Introduction: The main advantage of superelastic nickel-titanium (NiTi) products is their unique characteristic of force plateaus, which allow for clinically precise control of the force. The aims of this study were to define the mechanical characteristics of several currently available closed-coil retraction springs and to compare these products.

Methods: A universal test frame was used to acquire force-deflection diagrams of 24 NiTi closed-coil springs at body temperature.

View Article and Find Full Text PDF

Aim: The aim of this study was to investigate the corrosion resistance of orthodontic pliers from several manufacturers following different sterilization procedures, namely heat sterilization and the use of a disinfectant agent (Sekusept Extra N in an ultrasonic bath.

Material And Methods: Employed in this study were ten distal-end cutters and ten Weingart pliers manufactured by Aesculap, ETM and Hu-Friedy, examined under electron microscopy for evidence of corrosion following 500 sterilization cycles. The corrosion data were recorded photographically and graphically.

View Article and Find Full Text PDF