Publications by authors named "Matthias Goepfert"

Haemodynamic monitoring and management are cornerstones of perioperative care. The goal of haemodynamic management is to maintain organ function by ensuring adequate perfusion pressure, blood flow, and oxygen delivery. We here present guidelines on "Intraoperative haemodynamic monitoring and management of adults having non-cardiac surgery" that were prepared by 18 experts on behalf of the German Society of Anaesthesiology and Intensive Care Medicine (Deutsche Gesellschaft für Anästhesiologie und lntensivmedizin; DGAI).

View Article and Find Full Text PDF

Purpose: We aimed to investigate whether left ventricular diastolic dysfunction (LVDD) is associated with pulmonary edema in septic patients.

Methods: We conducted a prospective cohort study in adult septic patients between October 2018 and May 2019. We performed repeated echocardiography and lung ultrasound examinations within the first 7 days after diagnosis of sepsis.

View Article and Find Full Text PDF

Background: Diastolic dysfunction is a risk factor for postoperative major cardiovascular events. During anesthesia, patients with diastolic dysfunction might experience impaired hemodynamic function and worsening of diastolic function, which in turn, might be associated with a higher incidence of postoperative complications.We aimed to investigate whether patients with diastolic dysfunction require higher doses of norepinephrine during general anesthesia.

View Article and Find Full Text PDF

Background: In patients with hemodynamic instability echocardiography has been recommended as the preferred modality to evaluate the underlying pathophysiology. However, due to the fact that recent scientific data on the utilization of echocardiography in German Intensive Care Units (ICU) are scarce, we sought to investigate current practice.

Methods: A structured, web-based, anonymized survey was performed from May until July 2015 among members of the German Interdisciplinary Association of Critical Care and Emergency Medicine (DIVI) consisting of 14 questions.

View Article and Find Full Text PDF

Background: Monitoring cardiac output (CO) is important to optimize hemodynamic function in critically ill patients. The prevalence of aortic valve insufficiency (AI) is rising in the aging population. However, reliability of CO monitoring techniques in AI is unknown.

View Article and Find Full Text PDF

Background: Hemodynamic instability is frequent and outcome-relevant in critical illness. The understanding of complex hemodynamic disturbances and their monitoring and management plays an important role in treatment of intensive care patients. An increasing number of treatment recommendations and guidelines in intensive care medicine emphasize hemodynamic goals, which go beyond the measurement of blood pressures.

View Article and Find Full Text PDF

The problem of high rates of false alarms in patient monitoring in anesthesiology and intensive care medicine is well known but remains unsolved. False alarms desensitize the medical staff, leading to ignored true alarms and reduced quality of patient care. A database of intra-operative monitoring data was analyzed to find characteristic alarm patterns.

View Article and Find Full Text PDF

Background: Anesthetic administration is increasingly guided by electroencephalography (EEG)-based monitoring, such as the bispectral index (BIS). However, during cardiopulmonary bypass (CPB), factors other than the administered hypnotic agents may influence EEG signals, and their effects on BIS values are unknown.

Methods: This report is a secondary analysis of data from a prospective, controlled interventional study comparing the effect of sevoflurane administration guided by BIS monitoring (group SevoBIS) and constant administration of sevoflurane (group Sevo1.

View Article and Find Full Text PDF

This prospective single-center study aimed to determine the responsiveness and diagnostic performance of continuous cardiac output (CCO) monitors based on pulse contour analysis compared with invasive mean arterial pressure (MAP) during predefined periods of acute circulatory deterioration in patients undergoing transcatheter aortic valve implantation (TAVI). The ability of calibrated (CCO(CAL)) and self-calibrated (CCO(AUTOCAL)) pulse contour analysis to detect the hemodynamic response to 37 episodes of balloon aortic valvuloplasty enabled by rapid ventricular pacing was quantified in 13 patients undergoing TAVI. A "low" and a "high" cut-off limit were predefined as a 15 or 25 % decrease from baseline respectively.

View Article and Find Full Text PDF

Objective: In critical illness, hypoglycemia and hyperglycemia seem to influence outcome. While hypoglycemia can lead to organ dysfunction, hyperglycemia can lead to surgical site infections (SSI). In cardiac surgery, the use of blood cardioplegia is associated with high blood glucose levels.

View Article and Find Full Text PDF

Background: Electroencephalographic-based monitoring systems such as the bispectral index (BIS) may reduce anaesthetic overdose rates.

Objective: We hypothesised that goal-directed sevoflurane administration (guided by BIS monitoring) could reduce the sevoflurane plasma concentration (SPC) and intraoperative vasopressor doses during on-pump cardiac surgery.

Design: A prospective, controlled, sequential two-arm clinical study.

View Article and Find Full Text PDF

Background: The authors hypothesized that goal-directed hemodynamic therapy, based on the combination of functional and volumetric hemodynamic parameters, improves outcome in patients with cardiac surgery. Therefore, a therapy guided by stroke volume variation, individually optimized global end-diastolic volume index, cardiac index, and mean arterial pressure was compared with an algorithm based on mean arterial pressure and central venous pressure.

Methods: This prospective, controlled, parallel-arm, open-label trial randomized 100 coronary artery bypass grafting and/or aortic valve replacement patients to a study group (SG; n = 50) or a control group (CG; n = 50).

View Article and Find Full Text PDF

Background: The thermodilution curve assessed by transpulmonary thermodilution is the basis for calculation of global end-diastolic volume index (GEDI) and extravascular lung water index (EVLWI). Until now, it was unclear whether the method is affected by 1-lung ventilation. Therefore, aim of our study was to evaluate the impact of 1-lung ventilation on the thermodilution curve and assessment of GEDI and EVLWI.

View Article and Find Full Text PDF

Purpose: Transcardiopulmonary thermodilution (TPTD, SVTD) as well as calibrated (SVPC CAL) and uncalibrated (SVPC UNCAL) arterial pulse contour analysis (PC) are increasingly promoted as less-invasive technologies to measure stroke volume (SV) but their reliability in aortic valve disease was unknown. The objective of this prospective study was to investigate the validity of three less-invasive techniques to assess SV in conditions involving aortic stenosis (AS) and valvuloplasty-induced aortic insufficiency (AI) compared with transesophageal echocardiography.

Methods: In 18 patients undergoing transcatheter aortic valve implantation, SVTD and SVPC CAL were determined using a central pressure signal via the brachial artery and SVPC UNCAL using a peripheral radial signal.

View Article and Find Full Text PDF

Purpose: Severe acute pancreatitis (SAP) remains a life-threatening disease with classic etiology of systemic inflammatory response and mortality between 30 and 50 %. The aim of the present study is to compare two different treatment strategies of goal-directed hemodynamic management and evaluate their impact on survival, microcirculation, tissue oxygenation, and histopathologic damage in acute pancreatitis in a prospective animal study.

Methods: Thirty-four domestic pigs were randomly assigned to two different treatment groups.

View Article and Find Full Text PDF

Objective: The clinical value of stroke volume variations to assess intravascular fluid status in critically ill patients is well known. Electrical impedance tomography is a noninvasive monitoring technology that has been primarily used to assess ventilation. We investigated the potential of electrical impedance tomography to measure left ventricular stroke volume variation as an expression of heart-lung interactions.

View Article and Find Full Text PDF

Objective: The aim of this study was to assess whether thermodilution-derived parameters of right and left ventricular cardiac function (right ventricular ejection fraction, global ejection fraction, cardiac function index) are able to track changes of cardiac contractile function and whether they are influenced by substantial preload reduction.

Design: Prospective animal study.

Setting: University-affiliated animal research laboratory.

View Article and Find Full Text PDF

Background: Vital sign monitors and ventilator/anesthesia workstations are equipped with multiple alarms to improve patient safety. A high number of false alarms can lead to a "crying wolf" phenomenon with consecutively ignored critical situations. Systematic data on alarm patterns and density in the perioperative phase are missing.

View Article and Find Full Text PDF

Purpose Of Review: The purpose of this review is to focus on recent literature about sedation or anaesthesia in paediatric MRI. Special features of the MRI working environment, recent studies about sedation or anaesthesia, and success rates and risk profiles in this setting are presented. Finally, information for physicians to decide between sedation or anaesthesia in individual situations is presented.

View Article and Find Full Text PDF

Objective: We examined whether guiding therapy by an algorithm based on optimizing the global end-diastolic volume index (GEDVI) reduces the need for vasopressor and inotropic support and helps to shorten ICU stay in cardiac surgery patients.

Design And Setting: Single-center clinical study with a historical control group at an university hospital.

Patients: Forty cardiac bypass surgery patients were included prospectively and compared with a control group.

View Article and Find Full Text PDF