A comparative study on weak anion exchangers was performed to investigate the pH dependence, binding strength, particle size distribution, and static and dynamic capacity of the chromatographic resins. The resins tested included: DEAE Sepharose FF, Poros 50 D, Fractogel EMD DEAE (M), MacroPrep DEAE Support, DEAE Ceramic HyperD 20, and Toyopearl DEAE 650 M. Testing was performed with five different model proteins: Anti-FVII mAb (immunoglobulin G), aprotinin, bovine serum albumin (BSA), Lipolase (Novozymes), and myoglobin.