Publications by authors named "Matthew S Rosen"

Article Synopsis
  • Portable low-field magnetic resonance imaging (LF-MRI) offers a promising way to assess Alzheimer's disease (AD) patients in places where traditional MRI isn't available, despite some limitations in image quality.
  • * Researchers optimized LF-MRI techniques and created a free machine learning tool for analyzing brain structure and white matter changes in patients with cognitive impairments.
  • * The study found that LF-MRI accurately measures hippocampal volumes and white matter hyperintensities, suggesting that this technology can improve access to neuroimaging for dementia patients at a lower cost.
View Article and Find Full Text PDF

Tissue-mimicking reference phantoms are indispensable for the development and optimization of magnetic resonance (MR) measurement sequences. Phantoms have greatest utility when they mimic the MR signals arising from tissue physiology; however, many of the properties underlying these signals, including tissue relaxation characteristics, can vary as a function of magnetic field strength. There has been renewed interest in magnetic resonance imaging (MRI) at field strengths less than 1 T, and phantoms developed for higher field strengths may not be physiologically relevant at these lower fields.

View Article and Find Full Text PDF

Superparamagnetic iron oxide nanoparticles (SPIONs) are characterized by their exceptional susceptibility and relaxivity at ultra-low field (ULF) regimes, make them a promising contrast agent (CA) for ULF MRI. Despite their distinct advantages, the translation of these properties into clinically valuable image contrast in ULF MRI remains underexplored. In this study, we investigate the use of SPIONs to generate in vivo MRI contrast at 6.

View Article and Find Full Text PDF

Low-field (LF) MRI promises soft-tissue imaging without the expensive, immobile magnets of clinical scanners but generally suffers from limited detection sensitivity and contrast. The sensitivity boost provided by hyperpolarization can thus be highly synergistic with LF MRI. Initial efforts to integrate a continuous-bubbling SABRE (signal amplification by reversible exchange) hyperpolarization setup with a portable, point-of-care 64 mT clinical MRI scanner are reported.

View Article and Find Full Text PDF

Researchers are rapidly developing and deploying highly portable MRI technology to conduct field-based research. The new technology will widen access to include new investigators in remote and unconventional settings and will facilitate greater inclusion of rural, economically disadvantaged, and historically underrepresented populations. To address the ethical, legal, and societal issues raised by highly accessible and portable MRI, an interdisciplinary Working Group (WG) engaged in a multi-year structured process of analysis and consensus building, informed by empirical research on the perspectives of experts and the general public.

View Article and Find Full Text PDF

It has recently been shown that a bolus of hyperpolarized nuclear spins can yield stimulated emission signals similar in nature to maser signals, potentially enabling new ways of sensing hyperpolarized contrast media, including most notably [1-C]pyruvate that is under evaluation in over 50 clinical trials for metabolic imaging of cancer. The stimulated NMR signal emissions lasting for minutes do not require radio-frequency excitation, offering unprecedented advantages compared to conventional MR sensing. However, creating nuclear spin maser emission is challenging in practice due to stringent fundamental requirements, making practical in vivo applications hardly possible using conventional passive MR detectors.

View Article and Find Full Text PDF

Accurate image reconstruction is at the heart of diagnostics in medical imaging. Supervised deep learning-based approaches have been investigated for solving inverse problems including image reconstruction. However, these trained models encounter unseen data distributions that are widely shifted from training data during deployment.

View Article and Find Full Text PDF

Objective: For stroke patients with unknown time of onset, mismatch between diffusion-weighted imaging (DWI) and fluid-attenuated inversion recovery (FLAIR) magnetic resonance imaging (MRI) can guide thrombolytic intervention. However, access to MRI for hyperacute stroke is limited. Here, we sought to evaluate whether a portable, low-field (LF)-MRI scanner can identify DWI-FLAIR mismatch in acute ischemic stroke.

View Article and Find Full Text PDF
Article Synopsis
  • - Breast cancer screening is crucial for reducing mortality, but current methods have drawbacks, leading some women to skip regular checks.
  • - An ultra-low field (ULF) MRI was tested on 11 women, and radiologists successfully identified different types of breast tissue using this method.
  • - The early findings suggest that ULF MRI could be a comfortable, accessible, and cost-effective alternative for breast cancer screening and diagnosis.
View Article and Find Full Text PDF

Magnetic resonance imaging is a widespread clinical tool for the detection of soft tissue morphology and pathology. However, the clinical deployment of magnetic resonance imaging scanners is ultimately limited by size, cost, and space constraints. Here, we discuss the design and performance of a low-field single-sided magnetic resonance sensor intended for point-of-care evaluation of skeletal muscle in vivo.

View Article and Find Full Text PDF

Hyperpolarization chemistry based on reversible exchange of parahydrogen, also known as Signal Amplification By Reversible Exchange (SABRE), is a particularly simple approach to attain high levels of nuclear spin hyperpolarization, which can enhance NMR and MRI signals by many orders of magnitude. SABRE has received significant attention in the scientific community since its inception because of its relative experimental simplicity and its broad applicability to a wide range of molecules, however in vivo detection of molecular probes hyperpolarized by SABRE has remained elusive. Here we describe a first demonstration of SABRE-hyperpolarized contrast detected in vivo, specifically using hyperpolarized [1-C]pyruvate.

View Article and Find Full Text PDF

Background: Neuroimaging is essential for detecting spontaneous, nontraumatic intracerebral hemorrhage (ICH). Recent data suggest ICH can be characterized using low-field magnetic resonance imaging (MRI). Our primary objective was to investigate the sensitivity and specificity of ICH on a 0.

View Article and Find Full Text PDF

The standard of care for managing a patient with an implant is to identify the item and to assess the relative safety of scanning the patient. Because the 1.5 T MR system is the most prevalent scanner in the world and 3 T is the highest field strength in widespread use, implants typically have "MR Conditional" (i.

View Article and Find Full Text PDF

The advent of portable, low-field MRI (LF-MRI) heralds new opportunities in neuroimaging. Low power requirements and transportability have enabled scanning outside the controlled environment of a conventional MRI suite, enhancing access to neuroimaging for indications that are not well suited to existing technologies. Maximizing the information extracted from the reduced signal-to-noise ratio of LF-MRI is crucial to developing clinically useful diagnostic images.

View Article and Find Full Text PDF

We report on hyperpolarization of quadrupolar (I=3/2) Xe via spin-exchange optical pumping. Observations of the Xe polarization dynamics via in situ low-field NMR show that the estimated alkali-metal/Xe spin-exchange rates can be large enough to compete with Xe spin relaxation. Xe polarization up to 7.

View Article and Find Full Text PDF

In March 2022, the first ISMRM Workshop on Low-Field MRI was held virtually. The goals of this workshop were to discuss recent low field MRI technology including hardware and software developments, novel methodology, new contrast mechanisms, as well as the clinical translation and dissemination of these systems. The virtual Workshop was attended by 368 registrants from 24 countries, and included 34 invited talks, 100 abstract presentations, 2 panel discussions, and 2 live scanner demonstrations.

View Article and Find Full Text PDF
Article Synopsis
  • White matter hyperintensity (WMH) detected by MRI is linked to cognitive decline and stroke risk, prompting the exploration of portable MRI (pMRI) for diagnosing WMHs in non-traditional care settings.
  • In a study of 33 patients with both conventional and pMRI, there was strong agreement between raters identifying WMHs, indicating pMRI's reliability for detection.
  • A larger cohort of 91 patients further confirmed that pMRI effectively identified WMHs, particularly in underserved groups, suggesting its potential to improve access to neuroimaging and address healthcare disparities.
View Article and Find Full Text PDF

Conventional nuclear magnetic resonance (NMR) enables detection of chemicals and their transformations by exciting nuclear spin ensembles with a radio-frequency pulse followed by detection of the precessing spins at their characteristic frequencies. The detected frequencies report on chemical reactions in real time and the signal amplitudes scale with concentrations of products and reactants. Here, we employ Radiofrequency Amplification by Stimulated Emission of Radiation (RASER), a quantum phenomenon producing coherent emission of C signals, to detect chemical transformations.

View Article and Find Full Text PDF

In the 20th century, the advent of neuroimaging dramatically altered the field of neurologic care. However, despite iterative advances since the invention of CT and MRI, little progress has been made to bring MR neuroimaging to the point of care. Recently, the emergence of a low-field (<1 T) portable MRI (pMRI) is setting the stage to revolutionize the landscape of accessible neuroimaging.

View Article and Find Full Text PDF

Background: MRI-guidance techniques that dynamically adapt radiation beams to follow tumor motion in real time will lead to more accurate cancer treatments and reduced collateral healthy tissue damage. The gold-standard for reconstruction of undersampled MR data is compressed sensing (CS) which is computationally slow and limits the rate that images can be available for real-time adaptation.

Purpose: Once trained, neural networks can be used to accurately reconstruct raw MRI data with minimal latency.

View Article and Find Full Text PDF

Background Portable, low-field-strength (0.064-T) MRI has the potential to transform neuroimaging but is limited by low spatial resolution and low signal-to-noise ratio. Purpose To implement a machine learning super-resolution algorithm that synthesizes higher spatial resolution images (1-mm isotropic) from lower resolution T1-weighted and T2-weighted portable brain MRI scans, making them amenable to automated quantitative morphometry.

View Article and Find Full Text PDF

The spatial resolution of magnetic resonance imaging (MRI) is limited by the width of Lorentzian point spread functions associated with the transverse relaxation rate 1/. Here, we show a different contrast mechanism in MRI by establishing RASER (radio-frequency amplification by stimulated emission of radiation) in imaged media. RASER imaging bursts emerge out of noise and without applying radio-frequency pulses when placing spins with sufficient population inversion in a weak magnetic field gradient.

View Article and Find Full Text PDF

Brain imaging is essential to the clinical care of patients with stroke, a leading cause of disability and death worldwide. Whereas advanced neuroimaging techniques offer opportunities for aiding acute stroke management, several factors, including time delays, inter-clinician variability, and lack of systemic conglomeration of clinical information, hinder their maximal utility. Recent advances in deep machine learning (DL) offer new strategies for harnessing computational medical image analysis to inform decision making in acute stroke.

View Article and Find Full Text PDF

In the strong coupling regime with J-coupling much larger than chemical shift differences, J-coupling spectroscopy enables spectral identification of molecules even when conventional NMR fails. While this classically required the presence of a heteronucleus, we recently showed that J-coupling spectra can be acquired in many homonuclear systems using spin-lock induced crossing (SLIC). Here, we present an alternative method using a spin echo train in lieu of a spin-locking SLIC pulse, which has a number of advantages.

View Article and Find Full Text PDF

Introduction/aims: Magnetic resonance imaging (MRI) of peripheral nerves can provide image-based anatomical information and quantitative measurement. The aim of this pilot study was to investigate the feasibility of high-resolution anatomical and quantitative MRI assessment of sciatic nerve fascicles in patients with Charcot-Marie-Tooth (CMT) 1A using 7T field strength.

Methods: Six patients with CMT1A underwent imaging on a high-gradient 7T MRI scanner using a 28-channel knee coil.

View Article and Find Full Text PDF