ATR responds to mechanical stress at the nuclear envelope and mediates envelope-associated repair of aberrant topological DNA states. By combining microscopy, electron microscopic analysis, biophysical and in vivo models, we report that ATR-defective cells exhibit altered nuclear plasticity and YAP delocalization. When subjected to mechanical stress or undergoing interstitial migration, ATR-defective nuclei collapse accumulating nuclear envelope ruptures and perinuclear cGAS, which indicate loss of nuclear envelope integrity, and aberrant perinuclear chromatin status.
View Article and Find Full Text PDFCancer cells' ability to migrate through constricting pores in the tissue matrix is limited by nuclear stiffness. MT1-MMP contributes to metastasis by widening matrix pores, facilitating confined migration. Here, we show that modulation of matrix pore size or of lamin A expression known to modulate nuclear stiffness directly impinges on levels of MT1-MMP-mediated pericellular collagenolysis by cancer cells.
View Article and Find Full Text PDFCells move differently on substrates with different rigidities: the persistence time of their motion is higher on stiffer substrates. We show that this behavior-in and of itself-results in a net flux of cells directed up a soft-to-stiff gradient. Using simple random walk models with varying persistence and stochastic simulations, we characterize the propensity to move in terms of the durotactic index also measured in experiments.
View Article and Find Full Text PDFCytoskeleton (Hoboken)
March 2017
The microtubule organizing center (MTOC) frequently polarizes to a position in front of the nucleus during cell migration, but recent work has shown conflicting evidence for MTOC location in migratory polarized cells. Here, we show that subcellular localization of the MTOC is modulated by extracellular matrix stiffness. In scratch wound assays as well as single cell migration of mesenchymal stem cells (MSCs) the MTOC appears randomly positioned when cells are migrating on soft matrix, whereas on stiff matrix the MTOC is in front of the nucleus.
View Article and Find Full Text PDFCell migration has two opposite faces: although necessary for physiological processes such as immune responses, it can also have detrimental effects by enabling metastatic cells to invade new organs. In vivo, migration occurs in complex environments and often requires a high cellular deformability, a property limited by the cell nucleus. Here we show that dendritic cells, the sentinels of the immune system, possess a mechanism to pass through micrometric constrictions.
View Article and Find Full Text PDFDendritic cell (DC) migration in peripheral tissues serves two main functions: antigen sampling by immature DCs, and chemokine-guided migration towards lymphatic vessels (LVs) on maturation. These migratory events determine the efficiency of the adaptive immune response. Their regulation by the core cell locomotion machinery has not been determined.
View Article and Find Full Text PDFScarring is a long-lasting problem in higher animals, and reductionist approaches could aid in developing treatments. Here, we show that copolymerization of collagen I with polyacrylamide produces minimal matrix models of scars (MMMS), in which fractal-fibre bundles segregate heterogeneously to the hydrogel subsurface. Matrix stiffens locally-as in scars-while allowing separate control over adhesive-ligand density.
View Article and Find Full Text PDFCell movement has essential functions in development, immunity, and cancer. Various cell migration patterns have been reported, but no general rule has emerged so far. Here, we show on the basis of experimental data in vitro and in vivo that cell persistence, which quantifies the straightness of trajectories, is robustly coupled to cell migration speed.
View Article and Find Full Text PDFOn rigid surfaces, the cytoskeleton of migrating cells is polarized, but tissue matrix is normally soft. We show that nonmuscle MIIB (myosin-IIB) is unpolarized in cells on soft matrix in 2D and also within soft 3D collagen, with rearward polarization of MIIB emerging only as cells migrate from soft to stiff matrix. Durotaxis is the tendency of cells to crawl from soft to stiff matrix, and durotaxis of primary mesenchymal stem cells (MSCs) proved more sensitive to MIIB than to the more abundant and persistently unpolarized nonmuscle MIIA (myosin-IIA).
View Article and Find Full Text PDFPhysical features of microenvironments such as matrix elasticity E can clearly influence cell morphology and cell phenotype, but many differences between model matrices raise questions as to whether a standard biological scale for E exists, especially in 3D as well as in 2D. An E-series of two distinct types of hydrogels are ligand-functionalized here with non-fibrous collagen and used to elucidate wide-ranging cell and cytoskeletal responses to E in both 2D and 3D matrix geometries. Cross-linked hyaluronic acid (HA) based matrices as well as standard polyacrylamide (PA) hydrogels show that, within hours of initial plating, the adhesion, asymmetric shape, and cytoskeletal order within mesenchymal stem cells generally depend on E nonmonotonically over a broad range of physiologically relevant E.
View Article and Find Full Text PDFAlmost every laboratory that grows mammalian cells today grows their cells on tissue culture plastic, which was introduced to cell culture decades ago based on properties such as inertness, transparency, and so forth. However, plastic is rigid and unlike the many soft tissues in the body. Polymer gel systems that mimic the softness of various tissues have been developed over the past decade to test and understand the effects of rigidity on cells such as muscle cells.
View Article and Find Full Text PDFFibrotic rigidification following a myocardial infarct is known to impair cardiac output, and it is also known that cardiomyocytes on rigid culture substrates show a progressive loss of rhythmic beating. Here, isolated embryonic cardiomyocytes cultured on a series of flexible substrates show that matrices that mimic the elasticity of the developing myocardial microenvironment are optimal for transmitting contractile work to the matrix and for promoting actomyosin striation and 1-Hz beating. On hard matrices that mechanically mimic a post-infarct fibrotic scar, cells overstrain themselves, lack striated myofibrils and stop beating; on very soft matrices, cells preserve contractile beating for days in culture but do very little work.
View Article and Find Full Text PDFShrinking biosensors down to microscale dimensions enables increases in sensitivity and the ability to analyze minute samples such as the contents of individual cells. The goal of the present study is to create mobile microscale biosensors by attaching molecular beacons to microtubules and using kinesin molecular motors to transport these functionalized microtubules across two-dimensional surfaces. Previous work has shown that microfluidic channels can be functionalized with kinesin motors such that microtubules can be transported and directed through these channels without the need for external power or pressure-driven pumping.
View Article and Find Full Text PDF