Background: Regenerative electrodes are being explored as robust peripheral nerve interfaces for neuro-prosthetic control and sensory feedback. Current designs differ in electrode number, spatial arrangement, and porosity which impacts the regeneration, activation, and spatial distribution of fibers at the device interface. Knowledge of sensory and motor fiber distributions are important in optimizing selective fiber activation and recording.

View Article and Find Full Text PDF
Article Synopsis
  • The study investigates whether isoflurane conditioning provides neuroprotection against peripheral nerve injuries in a rodent model.
  • Adult male Lewis rats were divided into four groups based on their exposure to isoflurane after sciatic nerve injury, with some receiving multiple exposure sessions over consecutive days.
  • Results showed significant improvements in nerve function and structure (like increased axons and better muscle performance) in groups that underwent 3- and 6-day isoflurane conditioning, suggesting potential therapeutic benefits for nerve repair.
View Article and Find Full Text PDF

Background: Managing complex traumatic soft tissue wounds involving a large surface area while attempting to optimize healing, avoid infection, and promote favorable cosmetic outcomes is challenging. Regenerative materials such as ECMs are typically used in wound care to enhance the wound healing response and proliferative phase of tissue formation.

Case Report: The case reported herein is an example of the efficacious use of an SEFM in the surgical management of a large complex traumatic wound involving the left lower extremity and lower abdominal region.

View Article and Find Full Text PDF

Continuous monitoring of biomarkers at locations adjacent to targeted internal organs can provide actionable information about postoperative status beyond conventional diagnostic methods. As an example, changes in pH in the intra-abdominal space after gastric surgeries can serve as direct indicators of potentially life-threatening leakage events, in contrast to symptomatic reactions that may delay treatment. Here, we report a bioresorbable, wireless, passive sensor that addresses this clinical need, designed to locally monitor pH for early detection of gastric leakage.

View Article and Find Full Text PDF

Monitoring homeostasis is an essential aspect of obtaining pathophysiological insights for treating patients. Accurate, timely assessments of homeostatic dysregulation in deep tissues typically require expensive imaging techniques or invasive biopsies. We introduce a bioresorbable shape-adaptive materials structure that enables real-time monitoring of deep-tissue homeostasis using conventional ultrasound instruments.

View Article and Find Full Text PDF

Traditionally, full-thickness wounds with exposed structures are treated with flap coverage or dermal regenerative templates. Most dermal regenerative templates are biologic in origin, but recently synthetic options have become available. One such product is a synthetic hybrid-scale fiber matrix (SHSFM).

View Article and Find Full Text PDF

Contamination of surgical, traumatic, and chronic wounds with microorganisms presents a challenge to successful wound healing. In the present in vitro study, a synthetic electrospun fiber matrix (SEFM) cleared for use in the management of chronic, surgical, and traumatic wounds underwent USP (United States Pharmacopeia) <51> Antimicrobial Effectiveness Testing to determine its in vitro effectiveness against various microorganisms commonly found in non-healing wounds. The SEFM was tested in both sheet (s-SEFM) and micronized form (m-SEFM) against , , ,  , and .

View Article and Find Full Text PDF

Introduction: Large soft tissue defects resulting from trauma in the pediatric population are common. MLLs are a rare subset of these injuries with no standard treatment regimen. Thorough surgical debridement of these lesions is often warranted to remove necrotic tissue and contamination, which results in a large, open soft tissue defect.

View Article and Find Full Text PDF

Background: Direct current electrical stimulation may serve as a promising nonpharmacological adjunct promoting osteogenesis and fusion. The aim of this study was to evaluate the utility of electroactive spine instrumentation in the focal delivery of therapeutic electrical stimulation to enhance lumbar bone formation and interbody fusion.

Methods: A finite element model of adult human lumbar spine (L4-L5) instrumented with single-level electroactive pedicle screws was simulated.

View Article and Find Full Text PDF

Electrospun polymeric matrices have long been investigated as constructs for use in regenerative medicine, yet relatively few have been commercialized for human clinical use. In 2017, a novel electrospun matrix, composed of two synthetic biocompatible polymers, polyglactin 910 (PLGA 10:90) and polydioxanone (PDO) of varying pore and fiber sizes (i.e.

View Article and Find Full Text PDF

Introduction/aims: Although therapeutic electrical stimulation (TES) of injured peripheral nerve promotes axon regeneration and functional recovery, clinical applications of this therapy are limited to the intraoperative timeframe. Implantable, thin-film wireless nerve stimulators offer a potential solution to this problem by enabling delivery of electrical stimuli to an injured nerve over a period of several days post-surgery. The aim of this study was to determine the optimal time course of stimulation for maximizing functional recovery in a rat sciatic nerve isograft repair model.

View Article and Find Full Text PDF

Physically transient forms of electronics enable unique classes of technologies, ranging from biomedical implants that disappear through processes of bioresorption after serving a clinical need to internet-of-things devices that harmlessly dissolve into the environment following a relevant period of use. Here, we develop a sustainable manufacturing pathway, based on ultrafast pulsed laser ablation, that can support high-volume, cost-effective manipulation of a diverse collection of organic and inorganic materials, each designed to degrade by hydrolysis or enzymatic activity, into patterned, multi-layered architectures with high resolution and accurate overlay registration. The technology can operate in patterning, thinning and/or cutting modes with (ultra)thin eco/bioresorbable materials of different types of semiconductors, dielectrics, and conductors on flexible substrates.

View Article and Find Full Text PDF

Local electrical stimulation of peripheral nerves can block the propagation of action potentials, as an attractive alternative to pharmacological agents for the treatment of acute pain. Traditional hardware for such purposes, however, involves interfaces that can damage nerve tissue and, when used for temporary pain relief, that impose costs and risks due to requirements for surgical extraction after a period of need. Here, we introduce a bioresorbable nerve stimulator that enables electrical nerve block and associated pain mitigation without these drawbacks.

View Article and Find Full Text PDF

Background:  Commercially available near infrared spectroscopy devices for continuous free flap tissue oxygenation (StO) monitoring can only be used on flaps with a cutaneous component. Additionally, differences in skin quality and pigmentation may alter StO measurements. Here, we present a novel implantable heat convection probe that measures microvascular blood flow for peripheral monitoring of free flaps, and is not subject to the same issues that limit the clinical utility of near-infrared spectroscopy.

View Article and Find Full Text PDF

Implantable devices capable of targeted and reversible blocking of peripheral nerve activity may provide alternatives to opioids for treating pain. Local cooling represents an attractive means for on-demand elimination of pain signals, but traditional technologies are limited by rigid, bulky form factors; imprecise cooling; and requirements for extraction surgeries. Here, we introduce soft, bioresorbable, microfluidic devices that enable delivery of focused, minimally invasive cooling power at arbitrary depths in living tissues with real-time temperature feedback control.

View Article and Find Full Text PDF

Continuous, real-time monitoring of perfusion after microsurgical free tissue transfer or solid organ allotransplantation procedures can facilitate early diagnosis of and intervention for anastomotic thrombosis. Current technologies including Doppler systems, cutaneous O-sensing probes, and fluorine magnetic resonance imaging methods are limited by their intermittent measurements, requirements for skilled personnel, indirect interfaces, and/or their tethered connections. This paper reports a wireless, miniaturized, minimally invasive near-infrared spectroscopic system designed for uninterrupted monitoring of local-tissue oxygenation.

View Article and Find Full Text PDF

Serial examination and direct measurement of intracompartmental pressure (ICP) are suboptimal strategies for the detection of acute compartment syndrome (CS) because they are operator-dependent and yield information that only indirectly reflects intracompartmental muscle perfusion. As a result, instances of unnecessary fasciotomy and unrecognized CS are relatively common. Recently, near-infrared spectroscopy (NIRS)-based systems for compartment monitoring have generated interest as an adjunct tool.

View Article and Find Full Text PDF

Vascular pedicle thrombosis after free flap transfer or solid organ transplantation surgeries can lead to flap necrosis, organ loss requiring re-transplantation, or even death. Although implantable flow sensors can provide early warning of malperfusion and facilitate operative salvage, measurements performed with existing technologies often depend on extrinsic conditions such as mounting methods and environmental fluctuations. Furthermore, the mechanisms for fixing such probes to vascular or skeletal structures may disrupt the normal blood flow or cause unnecessary tissue damage.

View Article and Find Full Text PDF

Background: Rodent behavioral models with an electrophysiological component may require the joint operation of hardware from Med Associates, Inc. (St. Albans, VT) and Tucker-Davis Technologies (TDT; Alachua, FL).

View Article and Find Full Text PDF

Intuitive control of conventional prostheses is hampered by their inability to provide the real-time tactile and proprioceptive feedback of natural sensory pathways. The macro-sieve electrode (MSE) is a candidate interface to amputees' truncated peripheral nerves for introducing sensory feedback from external sensors to facilitate prosthetic control. Its unique geometry enables selective control of the complete nerve cross-section by current steering.

View Article and Find Full Text PDF

Background:  Current near-infrared spectroscopy (NIRS)-based systems for continuous flap monitoring are limited to flaps which carry a cutaneous paddle. As such, this useful and reliable technology has not previously been applicable to muscle-only free flaps where other modalities with substantial limitations continue to be utilized.

Methods:  We present the first NIRS probe which allows continuous monitoring of local tissue oxygen saturation (StO) directly within the substance of muscle tissue.

View Article and Find Full Text PDF

Background:  Current near-infrared spectroscopy (NIRS)-based systems for continuous flap monitoring are highly sensitive for detecting malperfusion. However, the clinical utility and user experience are limited by the wired connection between the sensor and bedside console. This wire leads to instability of the flap-sensor interface and may cause false alarms.

View Article and Find Full Text PDF

Background/aims: Bioelectric nerve stimulation (eStim) is an emerging clinical paradigm that can promote nerve regeneration after trauma, including within the context of diabetes. However, its ability to prevent the onset of diabetic peripheral neuropathy (DPN) has not yet been evaluated. Beyond the nerve itself, DPN has emerged as a potential contributor to sarcopenia and bone disease; thus, we hypothesized that eStim could serve as a strategy to simultaneously promote neural and musculoskeletal health in diabetes.

View Article and Find Full Text PDF

Background and objective High-frequency alternating current (HFAC) can yield a rapid-acting and reversible nerve conduction block. The present study aimed to demonstrate the successful implementation of HFAC block delivery via regenerative macro-sieve electrodes (MSEs). Methods Dual-electrode assemblies in two configurations [dual macro-sieve electrode-1 (DMSE-I), DMSE-II] were fabricated from pairs of MSEs and implanted in the transected and subsequently repaired sciatic nerves of two male Lewis rats.

View Article and Find Full Text PDF