Publications by authors named "Matthew L Magnuson"

Benzene contamination in drinking water systems affected by wildfires is a problem of emerging concern. Polyethylene pipes used in service lines and premise plumbing are vulnerable to permeation by benzene and can potentially cause challenges in sampling and remediation of contaminated systems. However, the kinetics and equilibria of the uptake of benzene by and release of benzene from pipes of differing polyethylene types and manufacturers are not well studied, leading to additional uncertainty when interpreting sampling data and selecting remediation options.

View Article and Find Full Text PDF

Per- and polyfluoroalkyl substances (PFAS) are a group of chemicals that have gained interest because some PFAS have been shown to have negative health effects and prolonged environmental and biological persistence. Chemicals classified as PFAS have a wide range of chemical moieties that impart widely variable properties, leading to a range of water treatment process efficacies. The Polanyi Potential Adsorption Theory was used to estimate Freundlich isotherm parameters to predict the efficacy of granular activated carbon (GAC) treatment for 428 PFAS chemicals for which the vast majority had no previously published treatment data.

View Article and Find Full Text PDF

Per- and polyfluoroalkyl substances (PFAS) are increasingly of interest to drinking water utilities due to state regulations, the release of federal and state health advisories, and public concern. Pilot-scale data were fitted for 16 PFAS species and five commercial-activated carbons using an open-source pore and surface diffusion model that includes an automated parameter-fitting tool. The estimated model parameters are presented, and an uncertainty analysis was evaluated considering the expected temporal variability of influent concentrations.

View Article and Find Full Text PDF

When contamination incidents occur in drinking water distribution systems, utilities need to select the remediation technologies most suited to their system-specific conditions and the contaminants of concern. Technology selection often involves balancing competing priorities. Multi-Criteria Decision Analysis (MCDA) is a promising approach that has been used extensively in other industries but not yet in drinking water system remediation.

View Article and Find Full Text PDF

Polymeric materials such as polyethylene are used extensively for indoor drinking water applications. These materials are subject to permeation by organic compounds such as those found in petroleum products and industrial chemicals, which can result in water quality issues with potential health effects. Although flushing is a common decontamination technique, disagreements and knowledge gaps in the scientific literature complicate prediction of how much flushing may be required to address organic contamination incidents.

View Article and Find Full Text PDF

Large volumes of contaminated water are produced via intentional and unintentional incidents, including terrorist attacks, natural disasters and accidental spills. Contaminated waters could contain harmful chemicals, which present management and disposal challenges. This study investigates three Advanced Oxidation Processes (AOPs) - UV/HO, O/HO, and electrochemical oxidation using a boron-doped diamond (BDD) anode - to treat eleven contaminants including herbicides, pesticides, pharmaceuticals, and flame retardant compounds.

View Article and Find Full Text PDF

The release of radiological material from a nuclear incident has the potential to cause extensive radiological contamination requiring rapid decontamination. A promising method for rapid remediation is the use of pressure washers to decontaminate building and street surfaces. Pressure washers utilize both physical removal through surface ablation and chemical removal through desorption of bonded radionuclides.

View Article and Find Full Text PDF

Intentional and unintentional contamination incidents, such as terrorist attacks, natural disasters, and accidental spills, can result in large volumes of contaminated water. These waters may require pre-treatment before disposal and assurances that treated waters will not adversely impact biological processes at wastewater treatment facilities, or receiving waters. Based on recommendations of an industrial workgroup, this study addresses such concerns by studying electrochemical advanced oxidation process (EAOP) pre-treatment for contaminated waters, using a boron-doped diamond (BDD) anode, prior to discharge to wastewater treatment facilities.

View Article and Find Full Text PDF

The use of cyanuric acid as a biomarker for ingestion of swimming pool water may lead to quantitative knowledge of the volume of water ingested during swimming, contributing to a better understanding of disease resulting from ingestion of environmental contaminants. When swimming pool water containing chlorinated cyanurates is inadvertently ingested, cyanuric acid is excreted quantitatively within 24 h as a urinary biomarker of ingestion. Because the volume of water ingested can be quantitatively estimated by calculation from the concentration of cyanuric acid in 24 h urine samples, a procedure for preservation, cleanup, and analysis of cyanuric acid was developed to meet the logistical demands of large scale studies.

View Article and Find Full Text PDF

This study examined the ability of activated sludge (AS) to sorb and biodegrade ethylmethylphosphonic acid (EMPA) and malathion, a degradation product and surrogate, respectively, for an organophosphate chemical warfare agent. Sorption equilibrium isotherm experiments indicate that sorption of EMPA and malathion to AS is negligible. EMPA at a concentration of 1 mg L(-1) degraded by approximately 30% with apparent first-order kinetics, possibly via co-metabolism from nitrification.

View Article and Find Full Text PDF

Intentional or accidental releases of contaminants into a water distribution system (WDS) have the potential to cause significant adverse health effects among individuals consuming water from the system. A flexible analysis framework is presented here for estimating the magnitude of such potential effects and is applied using network models for 12 actual WDSs of varying sizes. Upper bounds are developed for the magnitude of adverse effects of contamination events in WDSs and evaluated using results from the 12 systems.

View Article and Find Full Text PDF

Since the early 1990s, the FBI Laboratory has sponsored Scientific Working Groups to improve discipline practices and build consensus among the forensic community. The Scientific Working Group on the Forensic Analysis of Chemical, Biological, Radiological and Nuclear Terrorism developed guidance, contained in this document, on issues forensic laboratories encounter when accepting and analyzing unknown samples associated with chemical terrorism, including laboratory capabilities and analytical testing plans. In the context of forensic analysis of chemical terrorism, this guidance defines an unknown sample and addresses what constitutes definitive and tentative identification.

View Article and Find Full Text PDF

Although the herbicide atrazine has been reported to not react measurably with free chlorine during drinking water treatment, this work demonstrates that at contact times consistent with drinking water distribution system residence times, a transformation of atrazine can be observed. Some transformation products detected through the use of high performance liquid chromatography-electrospray mass spectrometry are consistent with the formation of N-chloro atrazine. The effects of applied chlorine, pH, and reaction time on the transformation reaction were studied to help understand the practical implications of the transformation on the accurate determination of atrazine in drinking waters.

View Article and Find Full Text PDF

Granular activated carbon is a frequently explored technology for removing synthetic organic contaminants from drinking water sources. The success of this technology relies on a number of factors based not only on the adsorptive properties of the contaminant but also on properties of the water itself, notably the presence of substances in the water which compete for adsorption sites. Because it is impractical to perform field-scale evaluations for all possible contaminants, the pore surface diffusion model (PSDM) has been developed and used to predict activated carbon column performance using single-solute isotherm data as inputs.

View Article and Find Full Text PDF

Some strains of Penicillium chrysogenum produce a proteinaceous hemolysin, chrysolysinTM, when incubated on sheep's blood agar at 37 degrees C but not at 23 degrees C. However, 92% (11/12) of the indoor air isolates produced hemolysis but only 43% (3/7) of the non-indoor air isolates did so. Chrysolysin is an aggregating protein composed of approximately 2kDa monomers, contains one cysteine amino acid, and has an isoelectric point of 4.

View Article and Find Full Text PDF

Seven retail hydroponic nitrate fertilizer products, two liquid and five solid, were comparatively analyzed for the perchlorate anion (ClO4-) by ion chromatography (IC) with suppressed conductivity detection, complexation electrospray ionization mass spectrometry (cESI-MS), normal Raman spectroscopy, and infrared spectroscopy using an attenuated total reflectance crystal (ATR-FTIR) coated with a thin film of an organometallic ion-exchange compound. Three of the five solid products were found by all techniques to contain perchlorate at the level of approximately 100-350 mg kg(-1). The remaining products did not contain perchlorate above the detection level of any of the techniques.

View Article and Find Full Text PDF

Ohio River water was treated by settling, sand filtration, and granular activated carbon filtration. It was then irradiated by low-pressure (monochromatic) and medium-pressure (polychromatic) UV lamps to investigate the effects of UV irradiation on the extracted organic matter (EOM). When the EOM, collected by solid phase extraction cartridges, was analyzed by conventional UV spectroscopy and size exclusion chromatography (SEC), no significant changes in the EOM were revealed for various UV doses.

View Article and Find Full Text PDF

Leaching of particle-bound metals affects the ability of settling ponds and other engineered structures to remove metallic pollutants, and leaching behavior is related to particle size. In this investigation, water borne soil particles were leached and fractionated with a split-flow thin cell, and the metal loadings were quantified as a function of particle size. For comparison of the metal-loading curves, different empirical modeling procedures were investigated to convert the data to a precise functional form suitable for quantitative comparison of changes in differential loading as a function of particle size.

View Article and Find Full Text PDF

Analytical chemistry is an important tier of environmental protection and has been traditionally linked to compliance and/or exposure monitoring activities for environmental contaminants. The adoption of the risk management paradigm has led to special challenges for analytical chemistry applied to environmental risk analysis. Namely, methods developed for regulated contaminants may not be appropriate and/or applicable to risk management scenarios.

View Article and Find Full Text PDF