The Epoch FullCoat Hip Stem (Zimmer) was an isoelastic composite femoral stem developed to address stem stiffness concerns. : We sought to evaluate the long-term bone mineral density (BMD) of a cohort of patients who underwent total hip arthroplasty (THA) using the Epoch isoelastic stem and having more than 2-decade follow-up. : We conducted a retrospective chart review of all patients who were study subjects at our institution in a multicenter prospective trial for the Food and Drug Administration of the Epoch implant in the mid-1990s.
View Article and Find Full Text PDFBackground: A uniquely designed, non-heat-treated moderately cross-linked acetabular polyethylene liner used in total hip arthroplasty (THA) demonstrated excessive wear during routine follow-up, prompting an evaluation of the linear wear rate.
Methods: All THAs were performed by the senior author. The study group included 38 THAs using the uniquely designed polyethylene in question, compared to a control group of 21 THAs using another moderately cross-linked polyethylene with good 10-year outcomes.
Readmission within 90 days following total joint arthroplasty has become a central quality measure of reimbursement initiatives; however, the validity of readmission rates as a measure of hospital care quality and the proportion of readmissions that are preventable are unknown. The purpose of this study is to determine if readmissions within 30 and 90 days after total knee arthroplasty (TKA) were related to orthopaedic or medical etiology and identify if these readmissions were preventable. We retrospectively reviewed 1,625 elective TKAs performed between 2011 and 2014 at our institution.
View Article and Find Full Text PDFBackground: We developed an orthopedic hospitalist fellowship program for our total joint replacement program at a large urban academic medical center. The goal of the program was to improve patient outcomes, quality, and healthcare value through collaborative perioperative care and improved care coordination. This study evaluates the implementation and impact of our modified Hospitalist-Orthopaedic Team Co-management model on quality and performance metrics.
View Article and Find Full Text PDFBackground: All polyethylene acetabular liners wear over time, and numerous methods for calculating linear wear rates exist. The objective of this study was to compare 2-dimensional wear rates between direct, micrometer measurements and the computerized, edge-detection method using Hip Analysis Suite (HAS) 8.0.
View Article and Find Full Text PDFBackground: Concerns have arisen regarding deterioration of wear properties of yttria-stabilized zirconia (YSZ) femoral head on conventional polyethylene (PE) bearings due to YSZ phase transformation.
Questions/purposes: The purpose of this study was to determine if there is a difference in long-term PE wear properties between YSZ and cobalt-chromium-molybdenum (Co-Cr-Mo) femoral heads.
Methods: Ten-year radiographic wear assessment was performed on a cohort of patients enrolled in a prospective randomized clinical trial comparing total hip arthroplasty with YSZ or Co-Cr-Mo femoral heads on conventional, non-cross-linked PE.
Background: During revision surgery with a well-fixed stem, a titanium sleeve can be used in conjunction with a ceramic head to achieve better stress distribution across the taper surface. In vitro testing suggests that corrosion is not a concern in sleeved ceramic heads; however, little is known about the in vivo fretting corrosion of the sleeves. The purpose of this study was to investigate fretting corrosion in sleeved ceramic heads in retrieved total hip arthroplasties.
View Article and Find Full Text PDFBackground: Previous studies identified imprinting of the stem morphology onto the interior head bore, leading researchers to hypothesize an influence of taper topography on mechanically assisted crevice corrosion. The purpose of this study was to analyze whether microgrooved stem tapers result in greater fretting corrosion damage than smooth stem tapers.
Methods: A matched cohort of 120 retrieved head-stem pairs from metal-on-polyethylene bearings was created controlling for implantation time, flexural rigidity, apparent length of engagement, and head size.
Background: Readmissions after total joint arthroplasty have become a key quality measure in elective surgery in the United States. The Affordable Care Act includes the Hospital Readmission Reduction Program, which calls for reduced payments to hospitals with excessive readmissions. This policy uses a method to determine excess readmission ratios and calculate readmission payment adjustments to hospitals, however, it is unclear whether readmission rates are an effective quality metric.
View Article and Find Full Text PDFBackground: Metal wear and corrosion products generated by hip replacements have been linked to adverse local tissue reactions. Recent investigations of the stem/head taper junction have identified this modular interface as another possible source of metal debris; however, little is known regarding other modular metallic interfaces, their ability to produce metal debris, and possibly to provide insight in the mechanisms that produce metal debris.
Questions/purposes: We asked three questions: (1) can we develop a reliable method to estimate volumetric material loss from the backside taper of modular metal-on-metal liners, (2) do backside tapers of modular metal-on-metal liners show a quantifiable volumetric material loss, and, if so, (3) how do regions of quantitatively identified material loss correspond to visual and microscopic investigations of surface damage?
Methods: Twenty-one cobalt-chromium (CoCr) liners of one design and manufacturer were collected through an institutional review board-approved retrieval program.
Background: Previous studies regarding modular head-neck taper corrosion were largely based on cobalt chrome (CoCr) alloy femoral heads. Less is known about head-neck taper corrosion with ceramic femoral heads.
Questions/purposes: We asked (1) whether ceramic heads resulted in less taper corrosion than CoCr heads; (2) what device and patient factors influence taper fretting corrosion; and (3) whether the mechanism of taper fretting corrosion in ceramic heads differs from that in CoCr heads.
Purpose: Remelted highly crosslinked polyethylenes (HXLPEs) were introduced in total knee replacement (TKR) starting in 2001 to reduce wear and particle-induced lysis. The purpose of this study was to investigate the damage mechanisms and oxidative stability of remelted HXLPEs used in TKR.
Methods: A total of 186 posteriorly stabilised tibial components were retrieved at consecutive revision operations.
Clin Orthop Relat Res
January 2013
Background: Knee stiffness or limited range of motion (ROM) after total knee arthroplasty (TKA) may compromise patient function. Patients with stiffness are usually managed with manipulation under anesthesia (MUA) to improve ROM. However, the final ROM obtained is multifactorial and may depend on factors such as comorbidities, implant type, or the timing of MUA.
View Article and Find Full Text PDFBackground And Purpose: There have been few reports documenting the wear and oxidation performance of the polyethylene bearing surface of HGPI and HGPII THA devices. We evaluated retrieved HGPI and HGPII acetabular liners that had been in situ for more than 10 years and determined whether there was a relationship between clinical and radiographic factors, surface damage, wear, and oxidation.
Materials And Methods: 129 HGPI and II acetabular liners with implantation times of > 10 years were retrieved at 4 institutions between 1997 and 2010.
The mechanisms of damage at the polyethylene post in 3 contemporary tibial insert designs were evaluated and compared with a historical standard (Insall-Burstein II; Zimmer, Warsaw, Ind). One hundred five gamma sterilized posterior-stabilized tibial inserts were revised after an average of 4.7 years (0.
View Article and Find Full Text PDFMetal-on-metal (MOM) hip resurfacing has become an increasingly popular treatment for young, active patients with degenerative disease of the hip, as bearing surfaces with better wear properties are now available. One proposed advantage of resurfacing is its ability to be successfully revised to total hip arthroplasty (THA). In addition, radiographic parameters that may predict failure in hip resurfacing have yet to be clearly defined.
View Article and Find Full Text PDFThe aim of this study was to better understand how in vivo oxidation contributes to fatigue damage in total knee arthroplasty (TKA). A total of 119 tibial inserts were consecutively collected after revision surgery. Of the 119 polyethylene retrievals, 29 were gamma sterilized in air (historical), whereas the remaining 90 were gamma sterilized in nitrogen (conventional).
View Article and Find Full Text PDFBackground: Postthrombotic syndrome (PTS) is a chronic condition in the lower extremity that develops after deep vein thrombosis (DVT). The incidence of PTS after total hip arthroplasty (THA) is not well established.
Questions/purposes: We (1) determined the incidence of PTS after DVT in patients undergoing primary THA for osteoarthritis; and (2) determined whether the incidence of PTS was greater in patients with DVT than without.
Nine cross-linked highly cross-linked ultrahigh-molecular weight polyethylene acetabular liners were retrieved at revision surgery. Eight of the liners were fully intact and functional at retrieval. Six cases contained shallow initiated cracks at the root of rim notches; 1 crack had propagated several millimeters.
View Article and Find Full Text PDFBackground: Wear of the ultra-high molecular weight polyethylene articular surface has been recognized as a major factor threatening the long-term success of total hip arthroplasty. Manual techniques that have been used to measure femoral head penetration into the polyethylene have been plagued with poor reproducibility and limited accuracy. Using a previously described phantom model simulating an unworn total hip arthroplasty, we previously demonstrated significant limitations in the accuracy of several widely used computerized wear measurement programs.
View Article and Find Full Text PDFOver a 10-year period, we prospectively evaluated the reasons for revision of contemporary and highly cross-linked polyethylene formulations in amulticenter retrieval program. Two hundred twelve consecutive retrievals were classified as conventional gamma inert sterilized (n = 37), annealed (Cross fire,[Stryker Orthopedics, Mahwah, NJ] n = 72), or remelted (Longevity [Zimmer ,Warsaw, Ind], XLPE[Smith and Nephew, Memphis, Tenn], Durasul [Zimmer,Warsaw, Ind] n = 103) liners. The most frequent reasons for revision were loosening (35%), instability(28%), and infection (21%) and were not related to polyethylene formulation (P = .
View Article and Find Full Text PDFUnlabelled: Revision total knee arthroplasty in patients with rheumatoid arthritis can be challenging. We asked whether we could confirm previously reported high failure rates following revision total knee arthroplasty in patients with rheumatoid arthritis. We therefore determined the Knee Society knee score and function scores, radiographic evidence of failure, and overall survival of the revision procedure in these patients.
View Article and Find Full Text PDFPostoperative anterior knee pain can be challenging after primary total knee arthroplasty. Isolated patellar resurfacing may provide symptomatic improvement in those patients with an unresurfaced patella. Seventeen isolated patellar resurfacing procedures were performed.
View Article and Find Full Text PDFUnlabelled: Postthrombotic syndrome (PTS) is characterized by edema, venous ectasia, hyperpigmentation, varicose veins, venous ulceration, and pain with calf compression after deep venous thrombosis (DVT). We determined the incidence of PTS after DVT diagnosed on screening ultrasound in patients undergoing primary total knee arthroplasty (TKA) for osteoarthritis (OA). We retrospectively reviewed the records of 1406 patients who underwent primary TKA for osteoarthritis and compared the incidence of PTS in patients without and with DVT.
View Article and Find Full Text PDF