Glomerular filtration rate (GFR) can be measured by observing the clearance of a suitable tracer from blood plasma after an intravenous injection. Slope-intercept GFR is an estimate of GFR calculated from an exponential fit to multiple blood sample measurements. The precision of the result depends on the uncertainties on all the measured quantities, but the most important factor is the error on the slope and intercept of the fit.
View Article and Find Full Text PDFBackground: Motion of the heart is known to affect image quality in cardiac PET. The prevalence of motion blurring in routine cardiac PET is not fully appreciated due to challenges identifying subtle motion artefacts. This study utilizes a recent prototype Data-Driven Motion Correction (DDMC) algorithm to generate corrected images that are compared with non-corrected images to identify visual differences in relative rubidium-82 perfusion images due to motion.
View Article and Find Full Text PDFBackground: In myocardial perfusion PET, images are acquired during vasodilator stress, increasing the likelihood of intra-frame motion blurring of the heart in reconstructed static images to assess relative perfusion. This work evaluated a prototype data-driven motion correction (DDMC) algorithm designed specifically for cardiac PET.
Methods: A cardiac torso phantom, with a solid defect, was scanned stationary and being manually pulled to-and-fro in the axial direction with a random motion.
Background: Patient motion during pharmacological stressing can have substantial impact on myocardial blood flow (MBF) estimated from dynamic PET. This work evaluated a motion correction algorithm with and without adjustment of the PET attenuation map.
Methods: Frame-by-frame motion correction was performed by three users on 30 rubidium-82 studies.
Background: Patient motion has been demonstrated to have a significant impact on the quality and accuracy of rubidium-82 myocardial perfusion PET/CT. This study aimed to investigate the effect on patient motion of two pharmacological stressing agents, adenosine and regadenoson.
Methods And Results: Dynamic data were retrospectively analyzed in 90 patients undergoing adenosine (n = 30), incremental adenosine (n = 30), or regadenoson (n = 30) rubidium-82 myocardial perfusion PET/CT.
Background: Rubidium-82 myocardial perfusion imaging is a well-established technique for assessing myocardial ischemia. With continuing interest on myocardial blood flow (MBF) and myocardial flow reserve (MFR) measurements, there is a requirement to fully appreciate the impact of technical aspects of the process. One such factor for rubidium-82 is prompt gamma compensation (PGC).
View Article and Find Full Text PDFOwing to expanding clinical indications, cardiac implantable electronic devices (CIEDs) are being increasingly used. Despite improved surgical techniques and the use of prophylactic antimicrobial therapy, the rate of CIED-related infection is also increasing. Infection is a potentially serious complication, with clinical manifestations ranging from surgical site infection and local symptoms in the region of the generator pocket to fulminant endocarditis.
View Article and Find Full Text PDFBackground: Quantitative assessment of [F]-FDG PET/CT images has been shown to be useful in the diagnosis of cardiac implantable electronic device (CIED) infection. This study aimed to compare the accuracy of various quantitative methods, using the same patient cohort and to assess the utility of dual time point imaging.
Methods: The study comprised a retrospective review of 80 [F]-FDG PET/CT studies.