Disturbances in cardiac rhythm affect a significant fraction of the population; they can have an ample range of repercussions on one person's quality of life, from negligible to lethal. As an implication, arrhythmias concern many private, commercial and public-passenger-vehicle driving licence holders. In their practice, medical professionals can be asked to assess an arrhythmia patient's fitness to drive effectively.
View Article and Find Full Text PDFAims: While several studies in the literature have reported results of catheter ablation of AF, few is known regarding outcome for more than 10 years.
Methods And Results: The complete population of patients who underwent AF ablation in the years 2002-2021 in the department of cardiology of the hospital of Reggio Emilia has been analysed. The last follow-up was made in the second half of 2022.
Aims: To explore the impact of the use of intracardiac echocardiography (ICE) in the ablation of supraventricular arrhythmias requiring transseptal catheterization (TSC), whilst analyzing the reduction in periprocedural complications and complications specifically related to TSC.
Methods: A retrospective multicenter study collecting data from consecutive atrial fibrillation (AF) and supraventricular ablation procedures that required TSC was performed in five Italian centers. Based on physician discretion, TSC was performed with or without ICE.
Aims: Syncope without prodromes in subjects with normal heart and normal electrocardiogram (ECG) is classified as non-classical neurally mediated syncope and is characterized by low adenosine plasma levels (APLs) and frequent asystolic syncope. We assessed the efficacy of theophylline, a non-selective adenosine receptor antagonist, in preventing syncopal events.
Methods And Results: Participants received an implantable cardiac monitor, underwent APL measurement, and received oral theophylline at maximum tolerated dose (starting dose 300 mg b.
Background: Radiofrequency ablation of the cavotricuspid isthmus is currently the first-choice treatment of typical atrial flutter and usually it is performed electively. The purpose of this study was to see whether performing on-line ablation has similar clinical results compared to the conventional strategy.
Methods: Consecutive patients (465) who underwent ablation of the cavotricuspid isthmus for typical atrial flutter (AFL) at our electrophysiology laboratory in the 2008-2017 decade were studied.
Introduction: Atrial tachycardia/fibrillation (AT/AF) episodes are common in implantable cardioverter-defibrillator (ICD) recipients and can be undetected by standard single-chamber devices. This study aims to explore whether a single-lead ICD with an atrial dipole (ICD DX; BIOTRONIK SE & Co, Berlin, Germany) could improve the AT/AF diagnosis and management as compared to standard ICD (ICD VR).
Methods And Results: We selected patients without AT/AF history from the THINGS registry which included consecutive patients implanted with ICD for standard indications.
Background: Patients affected by syncope without or with very short (≤5 s) prodrome with normal heart and normal ECG have been seen to present low plasma adenosine levels. We investigated whether chronic treatment of these patients with theophylline, a non-selective adenosine receptor antagonist, results in clinical benefit.
Methods: In a consecutive case-series of 16 patients (mean age 47 ± 25 years, 9 females) who had ECG documentation of asystolic syncope, we compared the incidence of syncopal recurrence during a period without and a period with tailored theophylline therapy.
Background: The mechanism of inappropriate sinus tachycardia (IST) remains incompletely understood.
Methods And Results: We prospectively compared 3 patient groups: 11 patients with IST (IST Group), 9 control patients administered isoproterenol (Isuprel Group), and 15 patients with cristae terminalis atrial tachycardia (AT Group). P-wave amplitude in lead II and PR interval were measured at a lower and higher heart rate (HR1 and HR2, respectively).
Aim: Ventricular tachycardia (VT)/ventricular fibrillation (VF) occurrence after cardiac resynchronization therapy-defibrillator (CRT-D) replacement is unknown; hence, there is no practical guideline to recommend either CRT-D or CRT-pacemaker at the time of device replacement. We observed the 1-year VT/VF occurrence after CRT-D replacement in a subanalysis of the Detect Long-term Complications after ICD Replacement (DECODE) registry.
Methods And Results: A total of 332 consecutive patients who had undergone CRT-D replacement from 2013 to 2015 were enrolled in 36 Italian centres.
In this case report, we look into the implant procedure of a single-lead ICD with floating atrial sensing dipole in a pregnant woman, without using fluoroscopy. This system benefits the proper positioning of the lead. This is possible thanks to the simultaneous display of both the atrial and ventricular dipoles on the electro-anatomical mapping system.
View Article and Find Full Text PDFBackground: "Unexplained syncope, no prodromes, and normal heart" has been described as a distinct clinical and biological entity.
Objective: The purpose of this study was to assess the mechanism of syncope.
Methods: In this prospective multicenter study, 58 patients presenting with unexplained syncope, no prodromes, and a normal heart received an implantable loop recorder (ILR) and were followed up until a diagnosis was established.
J Cardiovasc Electrophysiol
November 2016
Introduction: The aim of this study was to assess long-term results after single and multiple procedures of catheter ablation of ventricular tachycardia (VT). While it is generally accepted that multiple procedures are sometimes necessary in order to achieve long-term clinical success, the literature on this issue displays wide variability.
Methods: We assessed the outcome of 160 consecutive patients who underwent 214 ablation procedures in the period 2008 to May 2015: 93 had overt structural heart disease (SHD) (previous myocardial infarction in 74 cases) and 67 had no SHD.
Aims: We investigated the applicability of the Ventricular Capture Control (VCC) and Atrial Capture Control (ACC) algorithms for automatic management of cardiac stimulation featured by Biotronik pacemakers in a broad, unselected population of pacemaker recipients.
Methods And Results: Ventricular Capture Control and Atrial Capture Control were programmed to work at a maximum adapted output voltage as 4.8 V in consecutive recipients of Biotronik pacemakers.
Introduction: The longevity of defibrillators (ICD) is extremely important from both a clinical and economic perspective. We studied the reasons for device replacement, the longevity of removed ICD, and the existence of possible factors associated with shorter service life.
Methods And Results: Consecutive patients who underwent ICD replacement from March 2013 to May 2015 in 36 Italian centers were included in this analysis.
This case report describes how new tools and technologies can drive a different approach in the management of arrhythmic patients. An unknown and asymptomatic atrial flutter was detected by the atrial sensor mounted in a single lead implantable cardioverter defibrillator. Moreover daily remote monitoring of the device allowed early notification and prompt clinical reaction.
View Article and Find Full Text PDFAims: Left atrial ablation fails to prevent symptomatic recurrences of atrial fibrillation (AF) in 20-30% of patients up to 3 years of follow-up despite multiple procedures. Data are lacking on the long-term clinical outcome of those patients for whom the decision was taken to renounce performing further ablation procedures.
Methods And Results: In this multicentre study, 218 (34%) of 631 consecutive patients, who had undergone AF catheter ablation in the years 2001-11 for drug-refractory symptomatic AF, had symptomatic AF recurrences after 1.
Background: The concept of a single-lead dual-chamber implantable cardioverter defibrillator (ICD) with floating sensing atrial dipole has been proven safe and functional. We report a single-center experience with this ICD system; the major focus of the work is on the recorded atrial activation and its stability on a medium term follow-up.
Methods: Thirteen patients received a DX ICD (BIOTRONIK SE & Co, Berlin, Germany) with the Linox Smart S DX(ProMRI) ICD lead; the implantation data were reported.
Background: In the Third International Study on Syncope of Uncertain Etiology (ISSUE-3), cardiac pacing was effective in reducing recurrence of syncope in patients with presumed neurally mediated syncope (NMS) and documented asystole but syncope still recurred in 25% of them at 2 years. We have investigated the role of tilt testing (TT) in predicting recurrences.
Methods And Results: In 136 patients enrolled in the ISSUE-3, TT was positive in 76 and negative in 60.
Aims: The purpose of this study was to evaluate adherence to national guidelines on the non-pharmacologic (ablative) treatment of atrial fibrillation (AF).
Methods And Results: This prospective, observational, transversal study enrolled 1256 consecutive in- and outpatients referred to 43 cardiology departments between 1 and 31 October 2008 for the management of AF as a primary diagnosis. A rhythm-control strategy (cardioversion, antiarrhythmic medication, pace-maker implantation, substrate ablation, alone or in combination) was prescribed in 865 (69%) of the patients and a rate-control strategy [drugs, atrioventricular junction ablation and pace-maker implantation (Ablate and Pace)] in 285 (23%).
To investigate whether bradykinin (BK) participates in the inhibition of renal effects of exogenous angiotensin II (AngII) by AngII type 1 receptor (AT1R) blockade, eight salt-repleted volunteers underwent four p-aminohippurate- and inulin-based renal studies of AngII infusion at increasing rates of 0.625, 1.25, and 2.
View Article and Find Full Text PDF