Background: Catheter ablation (CA) can improve exercise tolerance and quality of life (QOL) in patients with atrial fibrillation (AF). However, its differential effects on muscle strength between paroxysmal AF (PAF) and nonparoxysmal AF (Non-PAF) remain unclear.
Methods: We evaluated 94 patients (67.
Background: This study aimed to develop a prediction model for intestinal perforation from meconium ileus (MI) based on findings from plain X-ray images.
Methods: Very low birth weight (VLBW) infants with MI hospitalized in two tertiary centers between 2011 and 2022 were included in this study. We retrospectively reviewed clinical parameters and assessed plain X-ray images from 0 to 5 days of age.
Background: Bipolar voltage amplitude is capable of helping determine the ideal lesion size index (LSI) setting during radiofrequency ablation for atrial fibrillation (AF).
Objective: We aimed to determine whether voltage-guided pulmonary vein isolation (PVI) is noninferior to conventional LSI-guided PVI in patients with nonvalvular AF.
Methods: This was a multicenter randomized trial conducted during a period of 12 months.
Background: Previous studies have identified noninvasive methods for predicting atrial fibrillation (AF) recurrence after catheter ablation (CA). We assessed the association between AF recurrence and atrial late potentials (ALPs), which were measured using P-wave signal-averaged electrocardiography (P-SAECG).
Methods: Consecutive patients with paroxysmal AF who underwent their first CA at our institution between August 2015 and August 2019 were enrolled.
Pediatr Surg Int
November 2022
The mechanical properties of the myocardium in the left ventricle and right atrium were estimated by simultaneously measuring the local impedance (LI) and contact force (CF) using an ablation catheter. Radiofrequency catheter ablation (RFCA) is a well-established arrhythmia treatment. Monitoring the RF power, CF and properties of myocardium during RFCA are necessary to estimate the effect of ablation.
View Article and Find Full Text PDFUnlabelled: A 48-year-old male with ischemic cardiomyopathy was admitted because of cardiogenic shock due to incessant ventricular tachycardia (VT). Despite the introduction of multiple mechanical cardiac support (MCS) devices, his hemodynamics were unstable; therefore, VT ablation was performed. Due to the limited vascular and left ventricle (LV) access with the multiple MCS devices, only the left femoral artery and vein were accessible.
View Article and Find Full Text PDFJ Interv Card Electrophysiol
March 2023
Background: The lesion size index (LSI) predicts radiofrequency (RF) ablation lesion size and is an established parameter for pulmonary vein isolation. However, the effectiveness and safety of LSI for cavotricuspid isthmus (CTI) linear ablation remain unclear.
Methods: This single-center retrospective study included 50 of patients (67 ± 10 years, 68% male) who underwent de novo CTI linear ablation between July 2020 and December 2020.
J Cardiovasc Electrophysiol
June 2022
Introduction: Direct comparison studies about the incidence of esophagogastric complications between radiofrequency (RF) and cryoballoon (CB) catheter ablation (CA) for atrial fibrillation (AF) have been scarce. We sought to elucidate the relationship between the pulmonary vein isolation (PVI) modalities and esophagogastric complications.
Methods: The study population consisted of 254 patients who underwent CA for AF from November 2017 to October 2018.
The recurrence of atrial fibrillation (AF) after catheter ablation (CA) is still an unsolved issue. Although structural remodeling is relatively well defined, the method to assess electrical remodeling of the atrium is not well established. In this study, we evaluated the relationship between atrial conduction properties and recurrence after CA for AF.
View Article and Find Full Text PDFThe wearable cardioverter defibrillator (WCD) has been available since 2014 in Japan, and its benefit in the in-hospital acute phase at high risk of ventricular tachyarrhythmia (VTA) has been established, but its clinical use in the outpatient setting remains unclear, especially in Japan. The subjects consisted of 43 consecutive patients with WCD use in the outpatient setting from April 2014 to October 2019 at the present institute. Event alerts and wearing compliance were checked via the remote monitoring system, and a dedicated WCD training team contacted the patients if necessary.
View Article and Find Full Text PDFBackground: Right ventricular (RV) pacing causes left ventricular (LV) dyssynchrony sometimes resulting in pacing-induced cardiomyopathy. However, RV pacing for hypertrophic obstructive cardiomyopathy is one of the treatment options. LV flow energy loss (EL) using vector flow mapping (VFM) is a novel hemodynamic index for assessing cardiac function.
View Article and Find Full Text PDFBackground Recent clinical trials have demonstrated the possible pleiotropic effects of SGLT2 (sodium-glucose cotransporter 2) inhibitors in clinical cardiovascular diseases. Atrial electrical and structural remodeling is important as an atrial fibrillation (AF) substrate. Methods and Results The present study assessed the effect of canagliflozin (CAN), an SGLT2 inhibitor, on atrial remodeling in a canine AF model.
View Article and Find Full Text PDFBackground: Gastric hypomotility (GH) is a possible complication of catheter ablation (CA) for atrial fibrillation (AF). However, it is unclear which factors are associated with GH. We sought to elucidate the relationship between the CA procedure and GH.
View Article and Find Full Text PDFJ Interv Card Electrophysiol
October 2021
Purpose: Ablation index (AI) is a useful tool of the CARTO® system to make effective lesions during pulmonary vein isolation (PVI) for atrial fibrillation (AF). However, the optimal distance between neighboring ablation points (interlesion distance (ILD)) is still unclear. Here, we evaluated the optimal ILDs in the AI-guided PVI.
View Article and Find Full Text PDFWe prospectively collected device and heart rate data through remote monitoring (RM) of patients with an implantable cardioverter defibrillator (ICD). The objective was to identify the predictors of lethal arrhythmic events (VT/VF).Thirty-three patients (mean age: 50 years) with ICDs [with functionality of heart rate variability (HRV) analysis] were divided into two groups [VT/VF (+), VT/VF (-) ].
View Article and Find Full Text PDFComplex atrial tachycardias (ATs) after catheter ablation or a MAZE procedure is sometimes difficult to determine the circuits of the tachycardia. A high-density, grid-shapes mapping catheter has been launched, which can be useful for detecting the detail circuits of tachycardias on three-dimensional mapping systems. The signal quality is also important for performing electrophysiological studies (EPSs), such as entrainment mapping, to identify the circuit.
View Article and Find Full Text PDFA 57-year-old man was admitted to our hospital due to syncopal attack. He was diagnosed with Brugada syndrome due to which a subcutaneous implantable cardiac defibrillator (S-ICD) was inserted using the standard technique. Two hours after the implantation, he experienced inappropriate shock while conscious.
View Article and Find Full Text PDFBackground: The relationship between atrial high-rate episode (AHRE) burden (i.e., the frequency of atrial tachyarrhythmia) and heart failure (HF) risk is unclear.
View Article and Find Full Text PDF