Publications by authors named "Matheoud R"

Purpose: The aim of this study was to evaluate the performance of myocardial perfusion imaging (MPI) systems in detecting perfusion defects (PDs). The defect perfusion index (DPI) was introduced to extend and further advance the current MPI quality metrics.

Methods: An anthropomorphic phantom simulating normal and pathological myocardial perfusion conditions was imaged by various NaI-crystal detector systems with and without corrections for scatter (SC) and attenuation (AC) (Symbia, Symbia + SC, Symbia IQ + SCAC, Symbia IQ), and cadmium-zinc-telluride detector systems without corrections (DSPECT, D530c).

View Article and Find Full Text PDF

Background: The diagnosis of amyotrophic lateral sclerosis (ALS) is primarily clinical, supported by the electromyographic examination to reveal signs of lower motor neuron damage. Identifying reliable markers of upper motor neuron (UMN) involvement is challenging. On this regard, the role of transcranial magnetic stimulation-induced motor-evoked potentials (TMS-MEPs), and its relationship with UMN burden, is still under investigation.

View Article and Find Full Text PDF

Purpose: Radiation doses to adult patients submitted to cerebral angiography and intracranial aneurysms treatments were assessed by using DICOM Radiation Dose Structured Reports (RDSR) and Monte Carlo simulations. Conversion factors to estimate effective and organ doses from Kerma-Area Product (P) values were determined.

Methods: 77 cerebral procedures performed with five angiographic equipment installed in three Italian centres were analyzed.

View Article and Find Full Text PDF

: Introduced in the latest BCLC 2022, endovascular trans-arterial radioembolization (TARE) has an important role in the treatment of unresectable hepatocellular carcinoma (HCC) as a "bridge" or "downstaging" of disease. The evolution of TARE technology allows a more flexible and personalized target treatment, based on the anatomy and vascular characteristics of each HCC. The flex-dose delivery program is part of this perspective, which allows us to adjust the dose and its radio-embolizing power in relation to the size and type of cancer and to split the therapeutic dose of Y90 in different injections (split-bolus).

View Article and Find Full Text PDF

Objectives: To assess the incidence (1 year) and the cumulative incidence (3 years) of the condition of patients accruing cumulative effective doses (CED) of ≥ 100 mSv and their variability among different hospitals. To establish and validate a reference level for the CED in patients with recurrent exposures (RERL) and provide a RERL value.

Methods: Data of CT exposure was collected in 9 similar hospitals.

View Article and Find Full Text PDF

Objective: To assess the cumulated exposure to radiation due to imaging in Hodgkin (HL) and diffuse large B-cell (DLBCL) lymphoma patients who were not submitted to radiotherapy.

Methods: The study population included 51 and 83 adult patients with HL and DLBCL, with a follow-up duration >1 year. The cumulated exposure was expressed using patient-specific data as cumulated effective dose (CED).

View Article and Find Full Text PDF
Article Synopsis
  • The study aimed to evaluate the eye lens doses experienced by interventional radiologists and the effectiveness of personal protective eyewear (PPE) in reducing these doses while simulating operator positions with a phantom.
  • Four types of PPE were tested, revealing their dose reduction factors (DRF) and correlations between eye lens doses and whole-body doses, along with dose measurements of the brain.
  • Results indicated that while all PPE showed significant DRF when used correctly, a single DRF value may not suit every situation; Kerma-Area Product (KAP) was identified as an important metric for radiation protection assessment.
View Article and Find Full Text PDF

Purpose: To study how the quantitative parameters of 18F-FDG PET imaging change with the emission scan duration (ESD) and the body-mass-index (BMI) in phantom and patients on a time-of-flight (TOF)-PET/CT system.

Methods: The image-quality phantom with (b-NEMA-IQ, BMI = 29.2 kg/m) and without (NEMA-IEC, BMI = 21.

View Article and Find Full Text PDF

This article presents the protocol on Quality Controls in PET/CT and PET/MRI published online in May 2022 by the European Federation of Organisations for Medical Physics (EFOMP), which was developed by the Working group for PET/CT and PET/MRI Quality Control (QC) protocol. The main objective of this protocol was to comprehensively provide simple and practical procedures that may be integrated into clinical practice to identify changes in the PET/CT/MRI system's performance and avoid short- and long-term quality deterioration. The protocol describes the quality control procedures on radionuclide calibrators, weighing scales, PET, CT and MRI systems using selected and measurable parameters that are directly linked to clinical images quality.

View Article and Find Full Text PDF

Background And Objectives: The ALS diagnosis requires an integrative approach, combining the clinical examination and supporting tests. Nevertheless, in several cases, the diagnosis proves to be suboptimal, and for this reason, new diagnostic methods and novel biomarkers are catching on. The F-fluorodeoxyglucose (F-FDG)-PET could be a helpful method, but it still requires additional research for sensitivity and specificity.

View Article and Find Full Text PDF

Purpose: An EFOMP Working Group (WG) was created in 2020 to establish recommendations for PET/CT/MRI Quality Control (QC). The WG's intention was to create a document containing a set of measurements suitable for routine practice. In order to map the current situation in PET facilities, the WG prepared a survey addressed to European Medical Physics Experts (MPE).

View Article and Find Full Text PDF

Background: The aim of the present study is to evaluate the reliability of a F-fluorodeoxyglucose (F-FDG) PET adaptive threshold segmentation (ATS) algorithm, previously validated in a preclinical setting on several scanners, for the biological target volume (BTV) delineation of head and neck radiotherapy planning.

Methods: [18F]FDG PET ATS algorithm was studied in treatment plans of head and neck squamous cell carcinoma on a dedicated workstation (iTaRT, Tecnologie Avanzate, Turin, Italy). BTVs segmented by the present ATS algorithm (BTVATS) were compared with those manually segmented for the original radiotherapy treatment planning (BTVVIS).

View Article and Find Full Text PDF

Objectives: To systematically review the published data regarding the cumulative exposure to radiation in selected cohorts of adults or paediatric patients due to diagnostic nuclear medicine examinations.

Methods: We conducted PubMed/Medline searches of peer-reviewed papers on cumulated effective dose (CED) from diagnostic nuclear medicine procedures published between 01 January 2010 until 31 January 2021. Studies were considered eligible if the contribution of nuclear medicine examinations to total CED was >10%.

View Article and Find Full Text PDF

Background: Time-of-flight (TOF) PET technology determines a reduction in the noise and improves the reconstructed image quality in low count acquisitions, such as in overweight patients, allowing a reduction of administered activity and/or imaging time. However, international guidelines and recommendations on the F-fluoro-2-deoxyglucose (FDG) activity administration scheme are old or only partially account for TOF technology and advanced reconstruction modalities. The aim of this study was to optimize FDG whole-body studies on a TOF-PET/CT scanner by using a multivariate approach to quantify how physical figures of merit related to image quality change with acquisition/reconstruction/patient-dependent parameters in a phantom experiment.

View Article and Find Full Text PDF

Background: Advances in medical imaging and interventional procedures have been associated with increased exposure to ionizing radiation. Thus, the International Commission on Radiological Protection (ICRP) established uniform safety standards to protect the general public against the dangers arising from ionizing radiations. In Europe, the ICRP standards are listed in the European Directive 2013/59/EURATOM, which should be transposed into national legislation by member states.

View Article and Find Full Text PDF

Objectives: To estimate the number of patients who receive a cumulative effective dose (CED) of ≥ 100 mSv from computed tomography (CT) in a single day or episode of care.

Methods: We examined 28,870 patients who underwent 49,834 CT examinations in a tertiary care centre in Italy in 2.5 years.

View Article and Find Full Text PDF

Background: This investigation used image data generated by an anthropomorphic phantom to determine the minimal Tc rest-stress activity concentration ratio (R) able to minimize the ghosting effect in the single-day stress-first myocardial perfusion imaging, using different positions of the perfusion defect (PD), scanners and reconstruction protocols.

Methods: A cardiac phantom with a simulated PD was imaged under different R using different gamma cameras and reconstruction algorithms. The residual activity from precedent stress administration was simulated by modeling effective half-times in each compartment of the phantom and assuming a delay of 3 hours between the stress and rest studies.

View Article and Find Full Text PDF

The reconstruction algorithms implemented on PET/CT scanners offer gain in activity recovery of small lesions at an extent that is not full known yet. METHODS: A cylindrical phantom with warm background and hot spheres filled with a Ge epoxy was acquired with four non-state-solid-detectors PET/CT scanners: mCT, Ingenuity TF, Discovery 710, and IQ. Images were reconstructed switching on and off time-of-flight (TOF), point spread function (PSF) modelling, and Bayesian penalised likelihood (BPL).

View Article and Find Full Text PDF

Conversion factors used to estimate effective (E) and organ doses (H) from air Kerma area product (KAP) are required to estimate population doses in percutaneous transhepatic biliary drainage (PTBD) and trans arterial chemoembolization (TACE) interventional procedures. In this study, E and H for ten critical organs/tissues, were derived in 64 PTBD and 48 TACE procedures and in 14,540 irradiation events from dosimetric, technical and geometrical information included in the radiation dose structured report using the PCXMC Monte Carlo model, and the ICRP 103 organ weighting factors. Conversion factors of: 0.

View Article and Find Full Text PDF

Purpose: The aim of this multicenter study was to evaluate the performance of the upgraded version of the Ingenuity TF PET/CT scanner, according to the NEMA NU-2 2012 standards.

Methods: Spatial resolution, sensitivity, count rate response, scatter fraction, image quality and accuracy were evaluated on three Ingenuity TF scanners installed in Italian hospitals. Furthermore, energy and timing resolution were measured.

View Article and Find Full Text PDF

Background: The aim of this study was to determine whether apparent diffusion coefficient (ADC) bi-component curve-fitting histogram analysis and volume percentage change (VPC) prior to bevacizumab treatment can stratify progression-free survival (PFS) and overall survival (OS) in patients with glioblastoma multiforme (GBM) on first recurrence.

Methods: We retrospectively evaluated 17 patients with recurrent GBM who received bevacizumab and fotemustine ( = 13) or only bevacizumab ( = 4) on first recurrence at our institution between December 2009 and July 2015. Both T2/FLAIR abnormalities and enhancing tumor on T1 images were mapped to the ADC images.

View Article and Find Full Text PDF

Purpose: We have recently demonstrated that iterative reconstruction algorithms with resolution recovery require the adoption of specific normal databases (NDBs) for perfusion SPECT quantification. This work was aimed at investigating the impact of patient low-dose imaging on NDBs and percent summed rest (SR%) and stress (SS%) scores.

Methods: Assuming that count statistics of shorter acquisition time may simulate that of lower patient dose, three simultaneous scans were acquired (BrightView, Philips) with different acquisition-time/projection: 30, 15 and 8 s (from 100% to 25% of the reference).

View Article and Find Full Text PDF

Background: The aim of the study was to assess the agreement between the left ventricular ejection fraction (LVEF) values obtained with IQ-SPECT and those obtained with a conventional gamma camera equipped with low-energy high-resolution (LEHR), considered as the method of reference.

Methods: Gated-stress MPI using 99mTc-tetrofosmin was performed in 55 consecutive patients. The patients underwent two sequential acquisitions (Method A and B) performed on Symbia-IQ SPECT with different acquisition times and one (Method C) on a Ecam SPECT equipped with LEHR collimators.

View Article and Find Full Text PDF

Oncologic F-FDG PET/CT acquisition and reconstruction protocols need to be optimized for both quantitative and detection tasks. To date, most studies have focused on either quantification or noise, leading to quantitative harmonization guidelines or appropriate noise levels. We developed and evaluated protocols that provide harmonized quantitation with optimal amounts of noise as a function of acquisition parameters and body mass.

View Article and Find Full Text PDF