Publications by authors named "Mateusz Orzalkiewicz"

Background: A substantial number of patients with severe aortic stenosis (AS) undergoing transcatheter aortic valve implantation (TAVI) experience adverse events after TAVI, with health care expenditure. We aimed to investigate cardiac remodeling and long-term outcomes in diabetic patients with severe AS, left ventricular ejection fraction (LVEF) < 50%, and extra-valvular cardiac damage (EVCD) undergoing TAVI treated with sodium-glucose cotransporter-2 inhibitors (SGLT2i) versus other glucose-lowering strategies (no-SGLT2i users).

Methods: Multicenter international registry of consecutive diabetic patients with severe AS, LVEF < 50%, and EVCD undergoing TAVI.

View Article and Find Full Text PDF

Background: New conduction disturbances are frequent after transcatheter aortic valve implantation (TAVI). Refining our ability to predict high-grade atrioventricular block (AVB) occurring later than 24 hours after the procedure would be useful in order to select patients eligible for early discharge.

Aims: This study was designed to identify predictors of high-grade AVB occurring between 24 hours and 30 days after TAVI and to develop and validate a predictive risk score.

View Article and Find Full Text PDF
Article Synopsis
  • - The study compares the outcomes of different balloon-expandable (BE) transcatheter heart valve (THV) devices used to treat high-risk patients with severe pure native aortic valve regurgitation (NAVR), revealing suboptimal results with both device types.
  • - Out of 144 patients treated, those with the MyVal device had more frequent extra-large annuli, yet technical success rates were similar between MyVal (90%) and Sapien (81%).
  • - Overall, while BE devices might offer a treatment option for high-risk patients with NAVR, their effectiveness is limited and highlights the need for dedicated devices, as larger sizes might improve outcomes for traditionally unsuitable patients.
View Article and Find Full Text PDF

Background: Severe pure aortic regurgitation (AR) carries a high mortality and morbidity risk, and it is often undertreated because of the inherent surgical risk. Transcatheter heart valves (THVs) have been used off-label in this setting with overall suboptimal results. The dedicated "purpose-built" Jena Valve Trilogy (JVT, JenaValve Technology) showed an encouraging performance, although it has never been compared to other THVs.

View Article and Find Full Text PDF

Transcatheter aortic valve implantation (TAVI) in native pure aortic regurgitation (AR) with off-label use of balloon-expandable valves (BEV) has been reported. However, there are scant data regarding optimal oversizing and its safety, and our study assessed BEV oversizing and outcomes of TAVI. Thirteen consecutive tricuspid aortic valve patients who underwent transfemoral TAVIs for pure AR with Sapien BEV at our center between 2019 and 2023 (69.

View Article and Find Full Text PDF

Acute coronary occlusion during transcatheter aortic valve implantation (TAVI) is a rare but potentially lethal complication. Main mechanisms are sinus insufficiency or sinus sequestration with well-described risk factors. We present two cases of acute right coronary artery occlusion during TAVI with a self-expanding valve in the absence of classical risk factors and propose a novel mechanism.

View Article and Find Full Text PDF
Article Synopsis
  • The study investigates the best timing for performing percutaneous coronary interventions (PCI) in patients undergoing transcatheter aortic valve implantation (TAVI), a procedure for severe aortic stenosis with existing coronary artery disease (CAD).
  • An analysis of 1,603 patients from the REVASC-TAVI registry shows that performing PCI after TAVI leads to better 2-year clinical outcomes, with significantly lower rates of all-cause death and major complications compared to PCI before or concurrently with TAVI.
  • The findings suggest that scheduling PCI after TAVI may be more beneficial, but further confirmation through randomized clinical trials is needed.
View Article and Find Full Text PDF

Background: Drug-coated balloons (DCBs) have shown comparable results with drug-eluting stents in small vessel disease (SVD) percutaneous coronary intervention (PCI) in terms of target vessel revascularization and a reduced incidence of myocardial infarction. However, the relatively high rate of bail-out stenting (BOS) still represents a major drawback of DCB PCI.

Aims: The aim of the study was to investigate the clinical, anatomic, and procedural features predictive of BOS after DCB PCI in SVD.

View Article and Find Full Text PDF

Background: The optimal access route in patients with severe peripheral artery disease (PAD) undergoing transcatheter aortic valve replacement (TAVR) remains undetermined.

Objectives: This study sought to compare clinical outcomes with transfemoral access (TFA), transthoracic access (TTA), and nonthoracic transalternative access (TAA) in TAVR patients with severe PAD.

Methods: Patients with PAD and hostile femoral access (TFA impossible, or possible only after percutaneous treatment) undergoing TAVR at 28 international centers were included in this registry.

View Article and Find Full Text PDF

Aims: Several causes have been reported for coronary artery ectasia (CAE), mostly atherosclerosis and tunica media abnormalities. The main aim of the present study was to investigate if CAE extension differs in distinct clinical settings.

Methods: Three hundred and forty-one patients with diagnosis of CAE were identified among 9659 coronary angiographies and divided into four groups according to the patient's admission diagnosis: stable or unstable angina (S-UA), myocardial infarction (MI), aortic disease, aortic valvular disease (AVD).

View Article and Find Full Text PDF

Transcatheter aortic valve implantation (TAVI) in noncalcified pure aortic valve regurgitation is challenging as dedicated valves are not widely available. We present a case series of four inoperable patients who underwent compassionate TAVI for this indication at our institution with a balloon-expandable valve. In this context, we analyzed the relevant technical aspects such as the need for larger oversizing of the transcatheter prosthesis and the safety and limits of valve overexpansion.

View Article and Find Full Text PDF
Article Synopsis
  • The study assesses the management of stable coronary artery disease (CAD) in patients undergoing transcatheter aortic valve implantation (TAVI), highlighting inconsistencies in existing evidence.
  • Using data from the REVASC-TAVI registry with 2407 patients, researchers compared outcomes between those who underwent complete versus incomplete myocardial revascularization.
  • Findings indicate no significant differences in all-cause death or composite outcomes (like stroke and rehospitalization for heart failure) between the two groups after 2 years, suggesting that the completeness of revascularization may not impact outcomes for TAVI patients with stable CAD.
View Article and Find Full Text PDF

Background: Coronary artery ectasia (CAE) is associated with ascending aortic (AA) ectasia. The purpose of this study is to evaluate the diagnostic performance of different echocardiographic parameters (EP) in predicting the presence of CAE.

Methods: Four hundred-eighteen patients with AA ectasia candidate to coronary angiography were identified and divided in two groups in respect of the presence of CAE.

View Article and Find Full Text PDF

Transcatheter aortic valve implantation has become a valid alternative to surgical aortic valve replacement for patients with symptomatic severe aortic stenosis, regardless of baseline surgical risk. The incidence of periprocedural complications has steadily declined over the years, thanks to technical advancement of transcatheter heart valves, delivery systems, and increased operators' experience. Beyond the most common periprocedural complications, there are a few uncommon but potentially severe complications that more often occur during follow-up, although they may also arise in the periprocedural phase.

View Article and Find Full Text PDF

Coronary artery disease (CAD) and severe aortic stenosis (AS) often coexist. When significant coronary lesions were found in patients undergoing surgical aortic valve replacement, combined coronary artery bypass grafting was the gold standard of treatment. Differently, the management of concomitant CAD in patients who are candidates for transcatheter aortic valve implantation (TAVI) is a matter of debate.

View Article and Find Full Text PDF

This study sought to investigate the impact of elective, uncomplicated target lesion revascularization (TLR) on long-term cardiac mortality after percutaneous coronary intervention (PCI) of unprotected left main coronary artery (ULMCA) disease. Consecutive patients undergoing PCI for ULMCA disease between January 2003 and December 2015 in 1 interventional center in Northern Italy were included. Patients presenting with cardiogenic shock, ST-segment elevation myocardial infarction (MI), as well as those undergoing urgent or complicated TLR were excluded.

View Article and Find Full Text PDF

Background: Incidence and long-term clinical consequences of prosthesis-patient mismatch (PPM) after transcatheter aortic valve replacement (TAVR) are still unclear.

Methods: We enrolled 710 consecutive patients who underwent TAVR. PPM was defined as absent if the index orifice area (iEOA) was >0.

View Article and Find Full Text PDF

Introduction: Indications for transcatheter aortic valve replacement (TAVR) are progressively extending to younger and lower risk patients. In this scenario, minimizing periprocedural complications and optimizing procedural result are both crucial to achieve an excellent long-term outcome.

Areas Covered: In this review, we summarize the main strategies that can be adopted before, during, and after TAVR to predict and prevent complications, to optimize procedural results and ultimately improve outcomes, with an emphasis on more recent evidence, new devices, and new techniques.

View Article and Find Full Text PDF

Background: Transcatheter aortic valve implantation (TAVI) is a valid alternative to surgical aortic valve replacement for the treatment of symptomatic aortic stenosis. The EuroScore (ES) II, logistic EuroScore (log ES), and the Society of Thoracic Surgeons (STS) score are the most applied scores for surgical risk stratification. However, their predictive value for patients undergoing TAVI is still unclear.

View Article and Find Full Text PDF

The role of glycoprotein IIb/IIIa inhibitors (GPI) in primary percutaneous coronary intervention (PPCI) remains uncertain. Previous analyses compare PPCI outcomes with clopidogrel plus GPI, versus without GPI. This does not reflect modern contemporary PPCI practice with ticagrelor or prasugrel.

View Article and Find Full Text PDF