Background: Time-resolved angiography with interleaved stochastic trajectories (TWIST) magnetic resonance angiography (MRA) may obscure smaller vessels and is highly susceptibility to motion artifacts, potentially reducing endoleak detection accuracy after endovascular aortic repair (EVAR). The novel golden-angle radial sparse parallel (GRASP) sequence enhances spatial and temporal resolution with continuous, motion-robust datasets, showing promise for accurate endoleak detection post-EVAR. This study aimed to compare the diagnostic effectiveness of contrast-enhanced compressed-sensing radial GRASP-volume interpolated breath-hold examination (VIBE) sequence with standard contrast-enhanced dynamic TWIST-VIBE sequence in patients with inconclusive computed tomography angiography (CTA) findings regarding endoleak after EVAR.
View Article and Find Full Text PDF: To assess free-breathing, dynamic radial magnetic resonance angiography (MRA) for detecting endoleaks post-endovascular aortic repair (EVAR) in cases with inconclusive computed tomography angiography (CTA). : This prospective single-center study included 17 participants (mean age, 70 ± 9 years; 13 males) who underwent dynamic radial MRI (Golden-angle RAdial Sparse Parallel-Volumetric Interpolated BrEath-hold, GRASP-VIBE) after inconclusive multiphasic CT for the presence of endoleaks during the follow-up of EVAR-treated abdominal aortic aneurysms. CT and MRI datasets were independently assessed by two radiologists for image quality, diagnostic confidence, and the presence/type of endoleak.
View Article and Find Full Text PDFIntroduction: To assess the outcomes after thoracic endovascular aneurysm repair (TEVAR) in the presence of intramural hematoma (IMH) in the proximal sealing zone.
Material And Methods: Patient data were retrospectively extracted from the hospital records of patients treated with TEVAR for acute and chronic aortic dissection type B in one single center. The initial, preoperative, first postoperative, and last follow-up CT scans were evaluated in the aortic 3D multiplanar reformats and the centerline regarding IMH presence in the proximal sealing zone, anatomical preconditions, and the morphological TEVAR complications including migration and bird-beak.
The aim was to assess the mid-term results of the E-iliac branched device. Baseline and follow-up data of this monocentric retrospective cohort study including all consecutive patients with aortoiliac aneurysms treated with iliac branched devices between 2016 and 2023 were extracted from the hospital records. Preoperative and follow-up CT scans were analyzed regarding endoleaks, migration, aneurysm sac remodeling, and device patency.
View Article and Find Full Text PDFPurpose: The aim was to assess the mid-term aortic remodeling and bare-metal stent (BMS) integrity of the restricted bare stent (RBS) technique reconstruction in aortic dissections.
Materials And Methods: This retrospective cohort study included prospectively collected patients treated with the modified RBS technique between 2017 and 2020. The preoperative, postoperative, and last follow-up computed tomographic (CT) scans were analyzed in the centerline at the mid-descending, celiac trunk (CeT), and the mid-abdominal levels for false lumen (FL) patency, aortic diameter, and true lumen (TL) diameter changes.
Objectives: The aim of this study was to assess the endograft position and aortic geometry changes after thoracic endovascular aortic repair (TEVAR) and frozen elephant trunk (FET) in distal stent-induced new entry (dSINE) patients.
Methods: In this retrospective cohort study, the baseline demographic and the follow-up data were extracted from the hospital records, and computed tomography scans of dSINE patients after TEVAR or FET between 2011 and 2021 were analysed regarding endograft oversizing, length and migration, taper ratio, aortic diameter at the endograft end, aortic elongation (thoracic inner and outer curvature), wedge apposition angle and tortuosity angle in the distal landing zone.
Results: dSINE was found in 22/213 (10%) of TEVAR and 10/31 (32%) of FET patients.
Eur J Cardiothorac Surg
July 2022
Branched endovascular aneurysm repair (BEVAR) is increasingly being performed with the off-the-shelf devices. We evaluated the use of the wire-assisted sheath stabilization technique for the new inner branch-based (iBEVAR), off-the-shelf E-nside endograft in 2 patients. The cannulation of the 8 reno-visceral target vessels and the BSG implantation were successfully performed using the total transfemoral approach.
View Article and Find Full Text PDFPurpose: The objective of this study was to compare the outcomes of patients treated with tube grafts and AFX stent-graft in the narrow infrarenal aortic anatomy.
Materials And Methods: Patients with penetrating aortic ulcers (PAUs) or sacciform aneurysms of the infrarenal aorta and an aortic bifurcation diameter ≤20 mm who underwent endovascular aneurysm repair (EVAR) with bifurcated AFX or tube stent-grafts (TUBE) between 2012 and 2020 were included. Demographic data and the outcome of the AFX group were compared with the TUBE group.
Aortoiliac occlusive disease may limit the use of branched endovascular aneurysm repair (BEVAR) of thoracoabdominal aneurysms (TAAAs). Thus, infrarenal aortoiliac occlusion may preclude the use of BEVAR. We present a case involving a 67-year-old patient with a fast-progressing TAAA (diameter: 70 mm) and a concomitant total aortoiliac occlusion.
View Article and Find Full Text PDFEur J Cardiothorac Surg
September 2021
Objectives: Our goal was to evaluate results of endovascular aortic arch repair using the Relay Branch system.
Methods: Forty-three patients with thoracic aortic pathology involving the aortic arch have been treated with the Relay Branch system (Terumo Aortic, Sunrise, FL, USA) in 10 centres. We assessed in-hospital mortality, neurological injury, treatment success according to current reporting standards and the need for secondary interventions.
Background: Our retrospective single-center study aimed to evaluate the safety of the carotid endarterectomy (CEA) in comparison to patients with untreated asymptomatic carotid stenosis ≥60% before CABG.
Methods: This single-center retrospective study included 174 patients with asymptomatic unilateral carotid stenosis treated between 2004 and 2017 with CABG. Thereof 106 patients had CEA before cardiac surgery either by a simultaneous (n = 62) or staged (n = 44) approach.
Background: We investigated the mid-term results of carotid-axillary bypass (CAB) in the setting of zone II thoracic endovascular aortic repair as an alternative method for the left subclavian artery (LSA) revascularization.
Methods: Our retrospective, single cohort study included all 69 patients from March 2015 to December 2018 with zone II thoracic endovascular aortic repair and CAB for the revascularization of the LSA. Demographics and clinical data were collected.
Interact Cardiovasc Thorac Surg
March 2020
Objectives: Our aim was to compare aortic remodelling in type B dissections after thoracic endovascular aortic repair (TEVAR) or conservative treatment.
Methods: We conducted a retrospective analysis of computed tomography (CT) data sets at dissection onset and at the last follow-up in a group with conservative (group A) and TEVAR treatment (group B). An additional analysis of the preoperative CT images was performed in patients from group A, who were converted to TEVAR during follow-up.
Objective: The aim of this study was to evaluate morphologic changes in dissected aortas after thoracic endovascular aortic repair (TEVAR) with the use of the Relay Nonbare stent graft stent graft by focusing on the geometric stent graft's performance in remodeling aortas.
Methods: We conducted a retrospective three-dimensional computed tomography analysis preoperatively, postoperatively, and 6 months after TEVAR in patients with residual dissection after type A and those with acute and chronic type B dissections at two German centers.
Results: Thirty-nine acute and 54 chronic aortic dissections were included.
The aim was to evaluate the incidence of stroke in the setting of cardiac surgery with or without hemodynamically relevant asymptomatic carotid stenosis contralateral to the occlusion. We designed a historical cohorts study, focused on patients with unilateral totally occluded internal carotid arteries who were referred for any cardiac surgery at our center. Isolated unilateral occlusions were assigned to group 1 (n = 60), and those with a contralateral stenosis grade ≥ 60% were included in group 2 (n = 51).
View Article and Find Full Text PDFThorac Cardiovasc Surg
August 2019
Background: Ascending aorta or hemi-arch repair are common in the acute phase of type A dissection. Postdissection aneurysms can develop with antegrade perfusion of the false lumen in the dissected aortic arch and require reoperation.
Methods: From 2012 to 2018, we reoperated nine patients with postdissection aneurysms using a hybrid technique without cardiopulmonary bypass.