Background: Dextro-transposition of the great arteries (dTGA) stands out as a prevalent cyanotic congenital heart defect (CHD), characterized by an intricate reversal in the arrangement of the major arteries. In the past, several surgical procedures have been used to treat dTGA, including the atrial switch. Although the method is no longer used, survivors of the procedure still living among us.
View Article and Find Full Text PDFBackground: An atrioventricular defibrillator system with a floating atrial dipole (VDD ICD) can provide atrial sensing by a single lead. Our aim was to compare the arrhythmia detection efficacy of VDD ICDs with conventional single- (VVI) and dual-chamber (DDD) defibrillators.
Methods: Data from consecutive patients undergoing ICD implantation were retrospectively analyzed.
Background: The subcutaneous implantable cardioverter-defibrillator (S-ICD) has emerged as an alternative to transvenous systems for prevention of sudden cardiac death. However, concerns have been raised regarding its efficacy and safety in obese individuals.
Objective: The purpose of this study was to perform a meta-analysis to evaluate the efficacy and safety of the S-ICD in patients with obesity by assessing the relationship between body mass index (BMI) and clinical outcomes.
Pacing Clin Electrophysiol
July 2024
Background: To preserve the benefit of atrial sensing without the implantation of an additional lead, a single-lead ICD system with a floating atrial dipole (DX ICD) has been developed. The purpose of this nationwide survey was to provide an overview of the current key influences of device selection focusing on DX ICD and to test the applicability of a previously published decision-making flowchart of ICD-type selection.
Methods: An online questionnaire was sent to all implanting centers in Hungary.
(1) Background: Early reintervention increases the risk of infection of cardiac implantable electronic devices (CIEDs). Some operators therefore delay lead repositioning in the case of dislocation by weeks; however, there is no evidence to support this practice. The aim of our study was to evaluate the impact of the timing of reoperation on infection risk.
View Article and Find Full Text PDFBackground: Kidney dysfunction (KD) is a main limiting factor of applying guideline-directed medical therapy (GDMT) and reaching the recommended target doses (TD) in heart failure (HF) with reduced ejection fraction (HFrEF).
Hypothesis: We aimed to assess the success of optimization, long-term applicability, and adherence of neurohormonal antagonist triple therapy (TT:RASi [ACEi/ARB/ARNI] + βB + MRA) according to the KD after a HF hospitalization and to investigate its impact on prognosis.
Methods: The data of 247 real-world, consecutive patients were analyzed who were hospitalized in 2019-2021 for HFrEF and then were followed-up for 1 year.
(1) Background: Besides the use of guideline-directed medical therapy (GDMT), multidisciplinary heart failure (HF) outpatient care (HFOC) is of strategic importance in HFrEF. (2) Methods: Data from 257 hospitalised HFrEF patients between 2019 and 2021 were retrospectively analysed. Application and target doses of GDMT were compared between HFOC and non-HFOC patients at discharge and at 1 year.
View Article and Find Full Text PDFChoosing the optimal device during cardiac resynchronization therapy (CRT) upgrade can be challenging. Therefore, we sought to provide a solution for identifying patients in whom upgrading to a CRT-defibrillator (CRT-D) is associated with better long-term survival than upgrading to a CRT-pacemaker (CRT-P). To this end, we first applied topological data analysis to create a patient similarity network using 16 clinical features of 326 patients without prior ventricular arrhythmias who underwent CRT upgrade.
View Article and Find Full Text PDFHerzschrittmacherther Elektrophysiol
December 2023
Electrical storm due to recurrent ventricular tachycardias (VTs) is a life-threatening arrhythmic emergency. The authors present a case report of a 69-year-old male patient with VT storm of non-ischemic etiology. Despite optimal medical treatment escalated by amiodarone antiarrhythmic drug therapy, the patient experienced multiple implantable cardioverter defibrillator (ICD) shocks.
View Article and Find Full Text PDFCardiac resynchronization therapy (CRT) is a cornerstone therapeutic opportunity for selected patients with heart failure. For optimal patient selection, no other method has been proven to be more effective than the 12-lead ECG, and hence ECG characteristics are extensively researched. The evaluation of particular ECG signs before the implantation may improve selection and, consequently, clinical outcomes.
View Article and Find Full Text PDFIntroduction: Renal dysfunction is a main limiting factor of applying and up-titrating guideline-directed medical therapy (GDMT) among patients with heart failure with reduced ejection fraction (HFrEF).
Objective: Our retrospective monocentric observational study aimed to analyse the application ratio of combined neurohormonal antagonist therapy (RASi: ACEI/ARB/ARNI + βB + MRA) and 12-month all-cause mortality differences in terms of renal dysfunction among HFrEF patients hospitalized for heart failure.
Method: We retrospectively analysed the cohort of consecutive HFrEF patients, hospitalized at the Heart Failure Unit of our tertiary cardiological centre in 2019-2021.
Introduction: Catheter ablation for atrial fibrillation (AF) is the most frequently performed cardiac ablation procedure worldwide. The majority of ablations can now be performed safely with minimal radiation exposure or even without the use of fluoroscopy, thanks to advances in 3-dimensional electroanatomical mapping systems and/or intracardiac echocardiography. The aim of this study was to conduct a meta-analysis to compare the effectiveness of zero fluoroscopy (ZF) versus non-zero fluoroscopy (NZF) strategies for AF ablation procedures.
View Article and Find Full Text PDFExpert Opin Pharmacother
November 2023
Introduction: Mexiletine is a class IB sodium-channel blocker. Unlike class IA or IC antiarrhythmic drugs, mexiletine rather shortens than prolongs action potential duration; therefore, it is less associated with proarrhythmic effects.
Areas Covered: Recently, new European Guidelines for the management of patients with ventricular arrhythmias and the prevention of sudden cardiac death were published, including a reappraisal of some established older antiarrhythmic drugs.
CIED, cardiac implantable electronic devices; CRT, cardiac resynchronization therapy; CRT-D, cardiac resynchronization therapy defibrillator; EA, electroanatomical; ICD, implantable cardioverter defibrillator; LBB, left bundle branch; LBBAP, left bundle branch area pacing; LV, left ventricular; LVEF, left ventricular ejection fraction; NT-proBNP, N-terminal pro-B-type natriuretic peptide; MRI, cardiac magnetic resonance imaging; S-ICD, subcutaneous defibrillator.
View Article and Find Full Text PDFIntroduction: Routine ultrasound (US) guidance for femoral venous access to decrease vascular complications of atrial fibrillation (AF) ablation procedures has been advocated. However, the benefit has not been unequivocally demonstrated by randomized-trial data.
Methods: Consecutive patients undergoing pulmonary vein isolation (PVI) on uninterrupted anticoagulant treatment were included.
Background: Mutations in the gene-encoding for the major Ca channel of the heart-may exhibit a variety of clinical manifestations. These include typical or atypical Timothy syndromes (TS) which are associated with multiple organ manifestations, and cardiac involvement in form of malignant arrhythmias, QTc prolongation, or AV block. "Cardiac only" Timothy syndrome (COTS) shows no extracardiac manifestation, whereas some gene mutations are associated with QTc prolongation alone (isolated long QT syndrome 8, LQT8).
View Article and Find Full Text PDFAims: During transvenous lead extraction (TLE) longer dwelling time often requires the use of powered sheaths. This study aimed to compare outcomes with the laser and powered mechanical tools.
Methods And Results: Single-centre data from consecutive patients undergoing TLE between 2012 and 2021 were retrospectively analysed.
Background: The subcutaneous implantable cardioverter-defibrillator (S-ICD) has been designed to overcome lead-related complications and device endocarditis. Lacking the ability for pacing or resynchronization therapy its usage is limited to selected patients at risk for sudden cardiac death (SCD).
Objective: The aim of this single-center study was to assess clinical outcomes of S-ICD and single-chamber transvenous (TV)-ICD in an all-comers population.
Introduction: Failure to isolate ipsilateral pulmonary veins (PV) "en bloc" by wide-area circumferential ablation (WACA) may necessitate ablation at the intervenous carina. It is unknown how this scenario impacts rates of atrial fibrillation (AF) recurrence.
Methods: A standard random-effect meta-analysis of randomized or observational studies were performed, where the outcome of first-time AF ablation was reported in patients with "en bloc" isolation of PVs by WACA as compared with those in whom ablation at the intervenous carina was needed after WACA to achieve complete isolation.
Introduction: Catheter ablations for cardiac arrhythmias are conventionally performed under fluoroscopic guidance. To guide these procedures, zero/minimal fluoroscopy (Z/MF) approaches have become available, using three-dimensional electroanatomical mapping systems. Our aim was to conduct a meta-analysis comparing these two different methods for the treatment of paroxysmal supraventricular tachycardia (SVT).
View Article and Find Full Text PDF