Purpose: To clarify the influence of clenching strength on interocclusal registration using an intraoral scanner (IOS).
Materials And Methods: The study includes eight volunteers as subjects, and the two experimental conditions were light clenching (LC) and 40% maximum voluntary clenching (MVC). Conventional silicone bite registration and an IOS were used for comparison.