Unlabelled: Oligometastatic patients at [F]F-Fluorocholine (F-choline) PET/CT may be treated with metastasis-directed therapy (MDT). The aim of this study was to combine radiomic parameters extracted from F-choline PET/CT and clinical data to build machine learning (ML) models able to predict MDT efficacy.
Methods: Oligorecurrent patients (≤5 lesions) at F-choline PET/CT and treated with MDT were collected.
Tech Innov Patient Support Radiat Oncol
June 2024
Purpose: In stereotactic body radiation therapy (SBRT) for prostate cancer, intrafraction motion is an important source of treatment uncertainty as it could not be completely smoothed through fractionation. Herein, we compared different arrangements and beam qualities for extreme hypofractionated treatments to minimize beam delivery time and so intrafractional errors.
Methods: A retrospective dataset of 11 patients was used.
To evaluate the clinical response rate and cosmetic outcome after full-dose intraoperative electron radiotherapy (IOERT) in early breast cancer (BC) treated with conserving surgery. Inclusion criteria were: >60 years old, clinical tumor size ≤2 cm, luminal A carcinoma, patological negative lymph nodes, excluded lobular carcinoma histology. IOERT was delivered with a dose of 21 Gy at 90% isodose.
View Article and Find Full Text PDFPurpose: This Technical Note validates previously published data about the dosimetry of the electron beams produced by a mobile accelerator dedicated for intraoperative radiation therapy (IORT). The evaluation of the directional response of a PTW microDiamond detector is presented together with a detailed analysis of the output factors (OFs) for bevelled applicators.
Methods: The OFs of the 6, 8, 10 and 12 MeV electron beams produced by a light intraoperative accelerator (LIAC, SIT, Italy) were measured in a commercial water phantom using the microDiamond.
The aim of this work was the investigation of the ion recombination and polarity factors (k ad k) for a PTW Advanced Markus ionization chamber exposed to proton and carbon ion beams at the Centro Nazionale di Adroterapia Oncologica. Measurements with protons were specifically dedicated for ocular treatments, in the low energy range and for small, collimated scanning fields. For both protons and carbon ions, several measurements were performed by delivering a 2D single energy layer of 3x3 cm and homogeneous, biologically-optimized SOBPs.
View Article and Find Full Text PDFPurpose: In carbon ion radiotherapy (CIRT), a simultaneous integrated boost (SIB) approach has not been fully exploited so far. The feasibility of a CIRT-SIB strategy for head and neck adenoid cystic carcinoma (ACC) patients was investigated in order to improve treatment planning dose distributions.
Methods And Materials: CIRT plans of 10 ACC patients treated at the National Center for Oncological Hadrontherapy (CNAO, Pavia, Italy) with sequential boost (SEQ) irradiation and prescription doses of 41.
Rectum and bladder volumes play an important role in the dose distribution reproducibility in prostate cancer adenocarcinoma (PCa) radiotherapy, especially for particle therapy, where density variation can strongly affect the dose distribution. We investigated the reliability and reproducibility of our image-guided radiotherapy (IGRT) and treatment planning protocol for carbon ion radiotherapy (CIRT) within the phase II mixed beam study (AIRC IG 14300) for the treatment of high-risk PCa. In order to calculate the daily dose distribution, a set of synthetic computed tomography (sCT) images was generated from the cone beam computed tomography (CBCT) images acquired in each treatment session.
View Article and Find Full Text PDFPurpose: To benchmark and evaluate the clinical viability of novel analytical GPU-accelerated and CPU-based Monte Carlo (MC) dose-engines for spot-scanning intensity-modulated-proton-therapy (IMPT) towards the improvement of lung cancer treatment.
Methods: Nine patient cases were collected from the CNAO clinical experience and The Cancer Imaging Archive-4D-Lung-Database for in-silico study. All plans were optimized with 2 orthogonal beams in RayStation (RS) v.
Purpose: The robustness against setup and motion uncertainties of gated four-dimensional restricted robust optimization (4DRRO) was investigated for hypofractionated carbon ion radiotherapy (CIRT) of lung tumors.
Methods: CIRT plans of 9 patients were optimized using 4DRRO strategy with 3 mm setup errors, 3% density errors and 3 breathing phases related to the gate window. The prescription was 60 Gy(RBE) in 4 fractions.
An Eye Tracking System (ETS) is used at CNAO for providing a stable and reproducible ocular proton therapy (OPT) set-up, featuring a fixation light (FL) and monitoring stereo-cameras embedded in a rigid case. The aim of this work is to propose an ETS set-up simulation algorithm, that automatically provides the FL positioning in space, according to patient-specific gaze direction and avoiding interferences with patient, beam and collimator. Two configurations are provided: one in the CT room for acquiring images required for treatment planning with the patient lying on a couch, and one related to the treatment room with the patient sitting in front of the beam.
View Article and Find Full Text PDFCurr Opin Otolaryngol Head Neck Surg
April 2021
Purpose: To investigate the impact of four-dimensional robust optimization (4DRO) on dose delivered to lung cancer patients in pencil beam scanning proton therapy.
Methods And Materials: 2 strategies were compared for 20 lung cancer patients, using a different number of breathing phases of the reconstructed 4D computed tomography (CT) included in the plan optimization problem. In the restricted approach combined with gating, only 3 phases close to reference end-exhale were considered instead of the whole breathing cycle.
Background: The aim of this study is to evaluate results in terms of local control (LC), overall survival (OS), and toxicity profile and to better identify factors influencing clinical outcome of skull base chordoma treated with proton therapy (PT) and carbon ion radiotherapy (CIRT).
Methods: We prospectively collected and analyzed data of 135 patients treated between November 2011 and December 2018. Total prescription dose in the PT group (70 patients) and CIRT group (65 patients) was 74 Gy relative biological effectiveness (RBE) delivered in 37 fractions and 70.
To compare radiation-induced toxicity and dosimetry parameters in patients with locally advanced nasopharyngeal cancer (LANPC) treated with a mixed-beam (MB) approach (IMRT followed by proton therapy boost) with an historic cohort of patients treated with a full course of IMRT-only. Twenty-seven patients with LANPC treated with the MB approach were compared to a similar cohort of 17 patients treated with IMRT-only. The MB approach consisted in a first phase of IMRT up to 54-60 Gy followed by a second phase delivered with a proton therapy boost up to 70-74 Gy (RBE).
View Article and Find Full Text PDFPurpose: Beam energy validation is a fundamental aspect of the routine quality assurance (QA) protocol of a particle therapy facility. A multilayer ionization chamber (MLIC) detector provides the optimal tradeoff between achieving accuracy in particle range determination and saving operational time in measurements and analysis procedures. We propose the characterization of a commercial MLIC as a suitable QA tool for a clinical environment with proton and carbon-ion scanning beams.
View Article and Find Full Text PDFPurpose: To perform the first dosimetric intercomparison for proton beams in Italy using ionization chambers, according to the IAEA TRS-398 code of practice.
Methods: Measurement sites included: National Center for Oncological Hadron Therapy (CNAO, Pavia), Center for Proton Therapy (CTP, Trento) and Center for Hadron Therapy and for advanced Nuclear Applications (CATANA, Catania). For comparison we also included a 6 MV photon beam produced at Istituti Clinici Scientifici Maugeri (ICSM, Pavia).
Purpose: To investigate for the first time the potentialities of obtaining microdosimetric measurements in scanned clinical carbon-ion beams using synthetic single crystal diamond detector and to verify the spectral conversion methods.
Methods: Microdosimetric measurements were performed at different depths in a water phantom at the therapeutic scanned carbon-ion beam of the National Center of Oncological Hadrontherapy (CNAO) in Pavia, using waterproof encapsulated diamond microdosimeter developed at "Tor Vergata" University. A monoenergetic carbon-ion beam of 195 MeV/μ scanned over a square field of 2 × 2 cm was used.
Purpose: At Centro Nazionale di Adroterapia Oncologica (CNAO, Pavia, Italy) ocular proton therapy (OPT) is delivered using a non-dedicated beamline. This paper describes the novel clinical workflow as well as technologies and methods adopted to achieve accurate target positioning and verification during ocular proton therapy at CNAO.
Method: The OPT clinical protocol at CNAO prescribes a treatment simulation and a delivery phase, performed in the CT and treatment rooms, respectively.
Within the dosimetric characterization of particle beams, laterally-integrated depth-dose-distributions (IDDs) are measured and provided to the treatment planning system (TPS) for beam modeling or used as a benchmark for Monte Carlo (MC) simulations. The purpose of this work is the evaluation, in terms of ion recombination and polarity effect, of the dosimetric correction to be applied to proton and carbon ion curves as a function of linear energy transfer (LET). LET was calculated with a MC code for selected IDDs.
View Article and Find Full Text PDFTo estimate the impact of dose calculation approaches adopted in different treatment planning systems (TPSs) on proton therapy dose delivered with pencil beam scanning (PBS). Treatment plans for six regular volumes in water and 15 clinical cases were optimized with Syngo-VC13 and exported for forward recalculation with Raystation-V7.0 pencil beam (RS-PBA) and Monte Carlo (RS-MC) algorithms and with the independent Fluka-MC engine.
View Article and Find Full Text PDFPurpose: Only few centers worldwide treat intraocular tumors with proton therapy, all of them with a dedicated beamline, except in one case in the USA. The Italian National Center for Oncological Hadrontherapy (CNAO) is a synchrotron-based hadrontherapy facility equipped with fixed beamlines and pencil beam scanning modality. Recently, a general-purpose horizontal proton beamline was adapted to treat also ocular diseases.
View Article and Find Full Text PDFPurpose: To dosimetrically characterize a multilayer ionization chamber (MLIC) prototype for quality assurance (QA) of pristine integral ionization curves (ICs) and spread-out-Bragg-peaks (SOBPs) for scanning light ion beams.
Methods: QUBE (De.Tec.
Background And Purpose: To compare RECIST 1.1 with volume modifications in patients with sacral chordoma not suitable for surgery treated with carbon ions radiotherapy (CIRT) alone. To evaluate patients pain before and after CIRT.
View Article and Find Full Text PDF