Publications by authors named "Massimo Sartori"

Commonly, quantitative gait analysis post-stroke is performed in fully equipped laboratories housing costly technologies for quantitative evaluation of a patient's movement capacity. Combining such technologies with an electromyography (EMG)-driven musculoskeletal model can estimate muscle force properties non-invasively, offering clinicians insights into motor impairment mechanisms. However, lab-constrained areas and time-demanding sensor setup and data processing limit the practicality of these technologies in routine clinical care.

View Article and Find Full Text PDF

The central nervous system employs distinct motor control strategies depending on task demands. Accordingly, the activity of alpha-motoneuron (MN) pools innervating skeletal muscle fibers is modulated based on muscle force and rate of force development (RFD). In human subjects, biophysical MN models enable inferring in vivo the neural processes (e.

View Article and Find Full Text PDF

Low-back pain is a common occupational hazard for industrial workers. Several studies show the advantages of using rigid and soft back-support passive exoskeletons and exosuits (exos) to reduce the low-back loading and risk of injury. However, benefits of using these exos have been shown to be task-specific.

View Article and Find Full Text PDF

Muscle fatigue is prevalent across different aspects of daily life. Tracking muscle fatigue is useful to understand muscle overuse and possible risk of injury leading to musculoskeletal disorders. Current fatigue models are not suitable for real-world settings as they are either validated using simulations or non-functional tasks.

View Article and Find Full Text PDF

One of the main technological barriers hindering the development of active industrial exoskeleton is today represented by the lack of suitable payload estimation algorithms characterized by high accuracy and low calibration time. The knowledge of the payload enables exoskeletons to dynamically provide the required assistance to the user. This work proposes a payload estimation methodology based on personalized Electromyography-driven musculoskeletal models (pEMS) combined with a payload estimation method we called "delta torque" that allows the decoupling of payload dynamical properties from human dynamical properties.

View Article and Find Full Text PDF

The main requirement for an amputee is to regain the function of the lost limb. In order to fully benefit from powered prosthetic legs, the user must rely on the dynamic control of the device. Progress in high-level control for powered prosthetic legs is currently challenged by the inability of current control schemes to generalize to large repertoires of movements as well as adapting to external mechanical demands.

View Article and Find Full Text PDF

Back support soft exosuits are promising solutions to reduce risk of musculoskeletal injuries at workplaces resulting from physically demanding and repetitive lifting tasks. Design of novel active exosuits address the impact on the muscle activity and metabolic costs but do not consider other critical aspects such as comfort and user perception during the intended tasks. Thus, in this study, we describe a novel soft active exosuit in line with its impact on physiological and subjective measures during lifting.

View Article and Find Full Text PDF

Latest advances in wearable exoskeletons for the human lower extremity predominantly focus on minimising metabolic cost of walking. However, there currently is no robotic exoskeleton that gains control on the mechanics of biological tissues such as biological muscles or series-elastic tendons. Achieving robotic control of biological tissue mechanics would enable prevention of musculoskeletal injuries or the personalization of rehabilitation treatments following injury with levels of precisions not attained before.

View Article and Find Full Text PDF

Trunk extensor muscle fatigue typically manifests as a decline in spectral content of surface electromyography. However, previous research on the relationship of this decline with trunk extensor muscle endurance have shown inconsistent results. The decline of spectral content mainly reflects the decrease in average motor unit action potential conduction velocity (CV).

View Article and Find Full Text PDF

Objective: Accurate estimation of stiffness across anatomical levels (i.e., joint, muscle, and tendon) in vivo has long been a challenge in biomechanics.

View Article and Find Full Text PDF

Understanding how motor units (MUs) contribute to skeletal mechanical force is crucial for unraveling the underlying mechanism of human movement. Alterations in MU firing, contractile and force-generating properties emerge in response to physical training, aging or injury. However, how changes in MU firing and twitch properties dictate skeletal muscle force generation in healthy and impaired individuals remains an open question.

View Article and Find Full Text PDF

Lower limb exoskeletons and exosuits ("exos") are traditionally designed with a strong focus on mechatronics and actuation, whereas the "human side" is often disregarded or minimally modeled. Muscle biomechanics principles and skeletal muscle response to robot-delivered loads should be incorporated in design/control of exos. In this narrative review, we summarize the advances in literature with respect to the fusion of muscle biomechanics and lower limb exoskeletons.

View Article and Find Full Text PDF

Assessing a patient's musculoskeletal function during over-ground walking is a primary objective in post-stroke rehabilitation, due to the importance of walking recovery for everyday life. However, the quantitative assessment of musculoskeletal function currently requires lab-constrained equipment, and labor-intensive analyses, which hampers assessment in standard clinical settings. The development of fully wearable systems for the online estimation of muscle-tendon forces and resulting joint torque would aid clinical assessment of motor recovery, it would enhance the detection of neuro-muscular anomalies and it would consequently enable highly personalized treatments.

View Article and Find Full Text PDF

Current laboratory-based setups (optical marker cameras + force plates) for human motion measurement require participants to stay in a constrained capture region which forbids rich movement types. This study established a fully wearable system, based on commercially available sensors (inertial measurement units + pressure insoles) that can measure both kinematic and kinetic motion data simultaneously and support wireless frame-by-frame streaming. In addition, its capability and accuracy were tested against a conventional laboratory-based setup.

View Article and Find Full Text PDF

Duchenne muscular dystrophy (DMD) is a genetic disorder that induces progressive muscular degeneration. Currently, the increase in DMD individuals' life expectancy is not being matched by an increase in quality of life. The functioning of the hand and wrist is central for performing daily activities and for providing a higher degree of independence.

View Article and Find Full Text PDF

Interfacing with alpha-motoneurons (MNs) is key to understand and control motor impairment and neurorehabilitation technologies. Depending on the neurophysiological condition of each individual, MN pools exhibit distinct neuro-anatomical properties and firing behaviors. Hence, the ability to assess subject-specific characteristics of MN pools is essential for unravelling the neural mechanisms and adaptations underlying motor control, both in healthy and impaired individuals.

View Article and Find Full Text PDF

The simultaneous modulation of joint torque and stiffness enables humans to perform large repertoires of movements, while versatilely adapting to external mechanical demands. Multi-muscle force control is key for joint torque and stiffness modulation. However, the inability to directly measure muscle force in the intact moving human prevents understanding how muscle force causally links to joint torque and stiffness.

View Article and Find Full Text PDF

Background: The development of bionic legs has seen substantial improvements in the past years but people with lower-limb amputation still suffer from impairments in mobility (e.g., altered balance and gait control) due to significant limitations of the contemporary prostheses.

View Article and Find Full Text PDF

The design of personalized movement training and rehabilitation pipelines relies on the ability of assessing the activation of individual muscles concurrently with the resulting joint torques exerted during functional movements. Despite advances in motion capturing, force sensing and bio-electrical recording technologies, the estimation of muscle activation and resulting force still relies on lengthy experimental and computational procedures that are not clinically viable. This work proposes a wearable technology for the rapid, yet quantitative, assessment of musculoskeletal function.

View Article and Find Full Text PDF

While a decreasing spectral content of surface electromyography reflects low back muscle fatigue development, reliability of these decreases may be insufficient. Decreasing frequency content is largely determined by decreasing average motor unit action potential conduction velocities (CV), which is considered a more direct measure of muscle fatigue development. However, for the low back muscles it has been proven difficult to identify propagating potentials and consequently estimate the CV.

View Article and Find Full Text PDF

Personalization of gait neuroprosthetics is paramount to ensure their efficacy for users, who experience severe limitations in mobility without an assistive device. Our goal is to develop assistive devices that collaborate with and are tailored to their users, while allowing them to use as much of their existing capabilities as possible. Currently, personalization of devices is challenging, and technological advances are required to achieve this goal.

View Article and Find Full Text PDF

Restoring natural motor function in neurologically injured individuals is challenging, largely due to the lack of personalization in current neurorehabilitation technologies. Signal-driven neuro-musculoskeletal models may offer a novel paradigm for devising novel closed-loop rehabilitation strategies according to an individual's physiology. However, current modelling techniques are constrained to bipolar electromyography (EMG), thereby lacking the resolution necessary to extract the activity of individual motor units (MUs) in vivo.

View Article and Find Full Text PDF