Spaghetti was prepared using dies made of different materials. The surface was observed using digital and optical microscopes, and was rougher for the spaghettis prepared using the Teflon, polypropylene, polycarbonate, aluminum, and bronze dies in this order. The extrusion velocity when passing through the die was faster, the bulk density was higher, and the rupture strength was greater for the spaghetti having the smoother surface.
View Article and Find Full Text PDFThe powder crystallites of L-alanine, selected for demonstration purposes, suspended in a photocurable resin were subjected to a frequency-modulated rotating magnetic field, and the achieved three-dimensional alignment was fixed by photopolymerization of the resin. The obtained sample exhibited the X-ray diffraction pattern that was comparable to the pattern of an equivalent actual original single crystal. This was achieved for the first time by the simultaneous alignment of the two magnetic axes, i.
View Article and Find Full Text PDFA diamagnetic particle with magnetic susceptibilities chi3 < chi2 = chi1 < 0 was subjected to a rotating magnetic field to obtain an alignment of the chi3 axis (the smallest susceptibility axis) in the direction perpendicular to the plane of the rotating magnetic field. A polymer short fiber, whose fiber axis coincides with the chi3 axis, was suspended in a fluid with the same density, and then a rotating magnetic field generated by a rotation of a pair of permanent magnets was applied. The fiber axis, rotating following the applied field, finally ended up with an alignment perpendicular to the plane of the rotating magnetic field.
View Article and Find Full Text PDFA theoretical study has been presented to show that it is possible to align three different diamagnetic susceptibility axes (chi(3) < chi(2) < chi(1) < 0) of a crystallite with respect to the laboratory coordinate system (x, y, z). The time-dependent magnetic field that periodically changes in direction and intensity on the xy plane in an elliptic manner (the intensity stronger in the x direction) at a rate quicker than the intrinsic rate of magnetic response causes the three-dimensional alignment, that is, chi(1) parallel x, chi(2) parallel y, and chi(3) parallel z. The fluctuation of the three susceptibility axes around the corresponding laboratory coordinates is estimated in terms of the fluctuation around the minimum of the time-averaged magnetic potential.
View Article and Find Full Text PDFObjective: The aim of the present study was to investigate the safety and acceptability of a new method of visualizing lymphatics, including sentinel lymph nodes (SNs), in lung cancer patients using multidetector computed tomography (MDCT).
Methods: Images were obtained using an MDCT scanner (Asteion Multi 4 Detector-Row; Toshiba) at 1, 2, and 3 minutes after percutaneous injection of 1 mL contrast medium (iohexol) near the tumor in 15 patients with small peripheral lung cancers (cT1N0M0). A lymph node was confirmed to be an SN if the attenuation was more than 30 Hounsfield units greater on postcontrast images than on precontrast images.