Background: The estimated continuous cardiac output (esCCO) system is a hemodynamic monitor that uses electrocardiograms and pulse oximeter waves to noninvasively estimate cardiac output. The coefficients for esCCO measurement have been established for adult patients, but the appropriate coefficients for pediatric patients are unclear. Therefore, this study determined esCCO coefficients for pediatric patients and validated the accuracy and tracking ability of a modified esCCO system.
View Article and Find Full Text PDFPurpose: Careful perioperative temperature management is important because it influences clinical outcomes. In pediatric patients, the esophageal temperature is the most accurate indicator of core temperature. However, it requires probe insertion into the body cavity, which is mildly invasive.
View Article and Find Full Text PDFIntraoperative hypotension (IOH) or highly invasive surgery adversely affects postoperative clinical outcomes. It is, however, unclear whether IOH affects postoperative acute kidney injury (AKI) depending on the invasiveness of abdominal surgery. We speculated that IOH in highly invasive abdominal surgery is a significant risk factor for postoperative AKI.
View Article and Find Full Text PDFPurpose: The estimated continuous cardiac output (esCCO) system was recently developed as a noninvasive hemodynamic monitoring alternative to the thermodilution cardiac output (TDCO). However, the accuracy of continuous cardiac output measurements by the esCCO system compared to TDCO under different respiratory conditions remains unclear. This prospective study aimed to assess the clinical accuracy of the esCCO system by continuously measuring the esCCO and TDCO.
View Article and Find Full Text PDFRecently, the Sherlock 3CG™ Tip Confirmation System, including a magnetic tracking system and an intracavitary electrocardiography guidance system, has been introduced for bedside peripherally inserted central catheter (PICC) insertion. Magnetic field sources interfere with the magnetic tracking system. Electromagnetic interference of the ventricular assist device (VAD) has already been reported with various devices but not on Sherlock 3CG™.
View Article and Find Full Text PDFWe firstly experienced a rare case demonstrating that massive volume of free air was aspirated from a large bore intravenous catheter sheath of the pulmonary arterial catheter during placement. A 44-year-old male patient underwent the emergency induction of anesthesia for transplantation of liver donated by the brain death subject. After the induction, the central venous and pulmonary artery catheter placement was conducted.
View Article and Find Full Text PDF