Publications by authors named "Masashi Kai"

Background: Perioperative right ventricular (RV) dysfunction is associated with increased morbidity and mortality in cardiac surgery patients. This study aimed to demonstrate proof of concept in generating intraoperative RV pressure-volume (PV) loops and conducting an end-systolic PV relationship (ESPVR) analysis using data obtained from routinely used intraoperative monitors.

Methods: Adult patients undergoing cardiac surgery with the placement of a pulmonary artery catheter (PAC) between May 2023 and March 2024 were included prospectively.

View Article and Find Full Text PDF

The emerging ex vivo machine perfusion (MP) enables the extension of ex situ intervals, potentially expanding the heart transplant (OHT) donor pool. From October 18, 2018, to June 30, 2023, isolated OHT using donation after brain death (DBD) from extended distances (>500 miles) were identified in the United Network for Organ Sharing database, and categorized into cold storage (non-MP, N = 1,212) and MP group (N = 152). The MP utilization rate for DBD hearts from extended distances surged from 0% in 2018 to 27.

View Article and Find Full Text PDF

Background: The Organ Care System (OCS) (Transmedics, Andover, MA) reduces cold ischemic time of donor hearts by producing a normothermic beating state during ex vivo perfusion, enabling extended ex situ intervals, which potentially increases donor pool. We aimed to compare outcomes in utilization of OCS and conventional cold storage technique.

Methods: Consecutive heart transplants following brain death at our institution between May 2022 and July 2023 were analyzed.

View Article and Find Full Text PDF

Background: The axillary artery (AX) access for intra-aortic balloon pump (IABP) as a bridge to heart transplant (HT) allows mobility while awaiting a suitable donor. As end-stage heart failure patients often have an implantable cardioverter defibrillator (ICD) on the left side, the left AX approach may be avoided due to the perception of difficult access and proximity of two devices. We aimed to evaluate the outcomes of patients bridged to HT with a left-sided AX IABP with or without ipsilateral ICDs.

View Article and Find Full Text PDF

Background: The new heart allocation policy places veno-arterial extracorporeal membrane oxygenation (VA-ECMO)-supported heart transplant (HT) candidates at the highest priority status. Despite increasing evidence supporting left ventricular (LV) unloading during VA-ECMO, the effect of LV unloading on transplant outcomes following bridging to HT with VA-ECMO remains unknown.

Methods And Results: From October 18, 2018 to March 21, 2023, 624 patients on VA-ECMO at the time of HT were identified in the United Network for Organ Sharing database and were divided into 2 groups: VA-ECMO alone (N=384) versus VA-ECMO with LV unloading (N=240).

View Article and Find Full Text PDF

Key Points: Simultaneous heart–kidney transplant is associated with high rates of kidney graft failure which are worse when compared with kidney transplant alone. The major causes of kidney graft failure in simultaneous heart–kidney transplant recipients were patient death and primary nonfunction of kidney graft.

Background: The indications and outcomes of simultaneous heart–kidney transplantation (SHKT) remain suboptimally defined.

View Article and Find Full Text PDF

Background: This study sought to analyze the details of strokes after acute type A dissection repair (ATAD) using a right axillary artery (RAX) first approach.

Methods: A total of 356 consecutive ATAD repairs from 2005 to 2022 were analyzed on the basis of arterial cannulation site. Strokes were evaluated by head computed tomography.

View Article and Find Full Text PDF

Background: We describe a technique to assess blood flow distal to the decannulation site after deployment of Perclose ProGlide (Abbott Vascular, Abbott Park, Ill) in patients on femoral veno-arterial extracorporeal membrane oxygenation (VA-ECMO) support.

Technique: An antegrade distal perfusion catheter was placed in all patients, and decannulation was primarily performed at bedside (N = 11/12). With the VA-ECMO circuit switched off, a needle was inserted into the arterial tubing, passed through the femoral arterial cannula into the artery.

View Article and Find Full Text PDF

: Acute ischemic stroke (AIS) following left ventricular assist device (LVAD) implantation is a serious complication associated with device morbidity. AIS development following LVAD placement typically presents between 6- and 24-months post implantation.: We report a case of a 67-year-old male who initially presented with reduced ejection fraction and severe coronary vessel disease.

View Article and Find Full Text PDF

Objective: With growing experience of acute type A aortic dissection repair, Zone 2 arch repair has been advocated. The aim of this study is to compare the outcome between "proximal-first" and "arch-first" Zone 2 repair.

Methods: From January 2015 to March 2023, 45 patients underwent Zone 2 arch repair out of 208 acute type A aortic dissection repairs: arch-first, N = 19, and proximal-first technique, N = 26, since January 2021.

View Article and Find Full Text PDF

Background: The management of complex groin wounds following VA-ECMO after heart transplant (HT) is uncertain due to limited experience. Sartorius muscle flaps (SMF) have been used in vascular surgery for groin wound complications. However, their use in HT recipients with perioperative VA-ECMO is unclear.

View Article and Find Full Text PDF

Background: The advent of direct-acting antivirals has helped to increase the safe utilization of organs from hepatitis C virus positive (HCV+) donors. However, the outcomes of heart transplantation (HT) using an HCV+ donor are unclear in recipients with underlying liver disease represented by an elevated model for end-stage liver disease excluding international normalized ratio (MELD-XI).

Methods: The United Network of Organ Sharing database was queried from Jan 2016 to Dec 2021.

View Article and Find Full Text PDF

Pulmonary hypertension (PH) is a relative contraindication to heart transplantation (HT). Multiple studies showed increased mortality in patients with PH. Advances in care may have led to improved outcomes in the modern era.

View Article and Find Full Text PDF

Severe mitral regurgitation (MR) is an important cause of acute heart failure and significant contributor to morbidity and mortality. Mechanical circulatory support (MCS) devices such as Impella are readily used to hemodynamically stabilize patients with cardiogenic shock (CS) secondary to this valvular pathology. Impella can also be combined with VA-ECMO to an "ECPELLA" configuration if further escalation of hemodynamic support is needed.

View Article and Find Full Text PDF

Background: Little is known about safety and efficacy of the use of Impella 5.5 compared to previous iterations in the setting of Impella with Veno-Arterial Extracorporeal Membrane Oxygenation Support as ECPELLA.

Methods: Consecutive patients who were treated by ECPELLA with surgically implanted axillary Impella 5.

View Article and Find Full Text PDF

Background: Data showing the efficacy and safety of the transplantation of hearts obtained from donors after circulatory death as compared with hearts obtained from donors after brain death are limited.

Methods: We conducted a randomized, noninferiority trial in which adult candidates for heart transplantation were assigned in a 3:1 ratio to receive a heart after the circulatory death of the donor or a heart from a donor after brain death if that heart was available first (circulatory-death group) or to receive only a heart that had been preserved with the use of traditional cold storage after the brain death of the donor (brain-death group). The primary end point was the risk-adjusted survival at 6 months in the as-treated circulatory-death group as compared with the brain-death group.

View Article and Find Full Text PDF

Background: The impact of using donors ≥50 years old on heart transplantation outcomes of septuagenarians is unknown, which may have a potential to expand the donor pool.

Methods: From January 2011 to December 2021, 817 septuagenarians received donor hearts <50 years old (DON<50) and 172 septuagenarians received donor hearts ≥50 years old (DON≥50) in the United Network for Organ Sharing database. Propensity score matching was performed using recipient characteristics (167 pairs).

View Article and Find Full Text PDF

Right ventricular (RV) dysfunction and resultant acute right heart failure (ARHF) is a rapidly growing field of interest, driven by increasing appreciation of its contribution to heart failure morbidity and mortality. Understanding of ARHF pathophysiology has advanced dramatically over recent years and can be broadly described as RV dysfunction related to acute changes in RV afterload, contractility, preload, or left ventricular dysfunction. There are several diagnostic clinical signs and symptoms as well as imaging and hemodynamic assessments that can provide insight into the degree of RV dysfunction.

View Article and Find Full Text PDF

Unlabelled: Scarcity of donor hearts continues to be a challenge for heart transplantation (HT). The recently Food and Drug Administration-approved Organ Care System (OCS; Heart, TransMedics) for ex vivo organ perfusion enables extension of ex situ intervals and thus may expand the donor pool. Because postapproval real-world outcomes of OCS in HT are lacking, we report our initial experience.

View Article and Find Full Text PDF

Background: The impact of the new heart allocation policy, which prioritizes acutely ill patients on temporary mechanical circulatory support and provides broader sharing of donor organs, on patient and graft survival in combined heart and kidney transplantation (HKT) is unknown.

Methods: In the United Network for Organ Sharing data, patients were divided in groups before and after the policy change (OLD, January 1, 2015 to October 17, 2018, N=533; and NEW, October 18, 2018 to December 31, 2020, N=370). Propensity score matching was performed utilizing recipient characteristics (283 pairs).

View Article and Find Full Text PDF

Background: There is paucity of data regarding reoperation after acute type A aortic dissection (ATAD) repair.

Methods: From October 2006 to March 2022, 75 patients received 123 reoperations after ATAD (proximal, n = 17; distal, n = 103; and both, n = 3) utilizing redo sternotomy (RS, n = 68), left thoracotomy (LT, n = 44), and endovascular approach (TEVAR, n = 11). The axillary artery cannulation was utilized in 97.

View Article and Find Full Text PDF

With the growing population of advanced heart failure, the use of Impella 5.5 has been increasing. Here, we report an effective strategy of removing the intra-aortic balloon pump (IABP) in the setting of escalation of support to Impella 5.

View Article and Find Full Text PDF

Background: In heart transplantation (HT), peripheral veno-arterial extracorporeal membranous oxygenation (VA-ECMO) is utilized preoperatively as a direct bridge to HT or postoperatively for primary graft dysfunction (PGD). Little is known about wound complications of an arterial VA-ECMO cannulation site which can be fatal.

Methods: From 2009 to 2021, outcomes of 80 HT recipients who were supported with peripheral VA-ECMO either preoperatively or postoperatively were compared based on the site of arterial cannulation: axillary (AX: N = 49) versus femoral artery (FA: N = 31).

View Article and Find Full Text PDF

A HeartMate 3 mini-apical cuff is designed to facilitate minimally invasive left ventricular assist implantation. A possible problem of using a mini-apical cuff is that multiple buttress braided sutures can interfere with a HeartMate 3 pump when locking the pump. If this happens in a minimally invasive approach, multiple manipulations to engage the pump can cause catastrophic myocardial injury and uncontrollable bleeding, especially in patients with a fragile myocardium.

View Article and Find Full Text PDF

We report a technique of heart transplantation performed by manubrium-sparing sternotomy for challenging re-entry after minimally invasive left ventricular assist device insertion. A T-shaped, manubrium-sparing sternotomy was performed using an oscillating saw up to the first intercostal space. After cardiopulmonary bypass was established via the right axillary artery and percutaneous venous cannulation of the right jugular and femoral vein, the outflow graft was ligated and divided via a left thoracotomy.

View Article and Find Full Text PDF