Publications by authors named "Masaru Kambe"

Objective: To determine pulmonary functional changes that predict early clinical outcomes in valve surgery requiring long cardiopulmonary bypass (CPB).

Methods: This retrospective study included 225 consecutive non-emergency valve surgeries with fast-track cardiac anesthesia between January 2014 and March 2020. Blood gas analyses before and 0, 2, 4, 8, and 14 h after CPB were investigated.

View Article and Find Full Text PDF

Background: Intra-aortic balloon pumping (IABP) markedly increases graft flow after coronary artery bypass grafting (CABG) with cardiopulmonary bypass. We sought to delineate the effects of IABP on graft flow after off-pump CABG (OPCAB).

Methods: The clinical records of 32 patients (25 male, 7 female; mean age: 70 ± 9 years) who underwent OPCAB with IABP between January 2011 and May 2015 were retrospectively reviewed.

View Article and Find Full Text PDF

A left ventricular aneurysm (LVA) generally results from myocardial infarction, but rarely LVA can be associated with dilated cardiomyopathy (DCM). We herein report a surgical case of malignant ventricular tachycardia (VT) in a patient with LVA associated with DCM. A 57-year-old woman was diagnosed with DCM and LVA when she 1st presented with sustained VT.

View Article and Find Full Text PDF

Objectives: A potential problem in aortic valve replacement (AVR) for patients with a small aortic annulus is prosthesis-patient mismatch (PPM). Although larger size prostheses have been well studied, the haemodynamics of 19-mm bioprostheses has been reported in only a small number of patients. The Trifecta valve is a novel bioprosthesis and its unique design is conceived to increase effective orifice area (EOA) and prevent PPM.

View Article and Find Full Text PDF

Sivelestat, a neutrophil elastase inhibitor, has been shown to attenuate pulmonary injury during ischemia and reperfusion by improving microcirculation and may be effective as a cardioprotective agent. Isolated rat hearts were Langendorff-perfused (constant pressure, 75 mmHg) with oxygenated Krebs-Henseleit bicarbonate buffer (KHB). The optimal sivelestat concentration at 19 micromol/l was revealed because left ventricular developed pressure (LVDP) recovery in 19 micromol/l sivelestat was highest among 0.

View Article and Find Full Text PDF

Background: Atrial tachycardia is a troublesome and medically refractory complication after surgery for atrial fibrillation. Incomplete surgical ablation during atrial fibrillation surgery can result in residual conduction over the lesions and postoperative atrial tachycardia. Intraoperative verification of conduction block would detect incomplete ablation lesions and direct repeat ablations to prevent postoperative atrial tachycardia.

View Article and Find Full Text PDF