Purpose: In the practice code of dosimetry, humidity effect is assumed to be constant as far as the measurements are performed in the relative humidity (RH) range of (20-80)%; thus, the humidity effect can be ignored with a dose uncertainty of 0.15%. This assumption is based on the previous experimental results by Niatel and Guiho.
View Article and Find Full Text PDFNihon Hoshasen Gijutsu Gakkai Zasshi
August 2006
A Japanese code of practice for clinical dosimetry, titled "Standard Dosimetry of Absorbed Dose in External Beam Radiotherapy" was published by the Japan Society of Medical Physics (JSMP) in 2002. It mostly followed IAEA Technical Reports Series No. 398, which was based on N(D,w), i.
View Article and Find Full Text PDFNihon Hoshasen Gijutsu Gakkai Zasshi
March 2005
Because the exposure dose in X-ray computed tomography examinations is sometimes difficult to determine, it is important to be able to estimate the dose for these examinations. The effective energy of the X-ray CT scanner is required to estimate exposure dose. Although the half-value-layer (HVL) method has been used to calculate effective energy, it is not an easy method.
View Article and Find Full Text PDFRecently, the number of scans for X-ray computed tomography (CT) examinations has been rising due to the wide-spread use of multi-slice CT (MSCT) scanners. There is a concern that the total medical exposures will be increased by these examinations. In order to lower exposures, routine parameters for head CT examinations done at several hospitals in Gunma were investigated.
View Article and Find Full Text PDFA new characterization of depth-ionization parameters for electron beams is empirically deduced from our data analysis based on the divided difference method (the DD method), which employs the numerical differential of an ionization curve. The important feature of the present method is that it does not necessarily require normalized percent depth-ionization (NPDI) data. The depth of 50% of maximum ionization, I50, which is an important parameter for electron beam dosimetry, can be deduced from the analysis of an unnormalized (or partial) depth-ionization (UDI) curve obtained over a short interval of depth.
View Article and Find Full Text PDFNihon Hoshasen Gijutsu Gakkai Zasshi
June 2004
The purpose of this study was to determine whether or not salivary gland dysfunction occurs within the first three months after brachytherapy in patients with head and neck carcinoma. Of the 20 patients with head and neck squamous cell carcinoma included in this study, 11 were treated with brachytherapy and the remaining 9 patients received external irradiation. All the patients underwent a salivary gland scintigraphy before and after radiotherapy.
View Article and Find Full Text PDFIgaku Butsuri
January 2001
In order to confirm quality assurance and quality control in radiation therapy, it is common to perform a monitor unit verification calculation independent on RTP system. Generally, this verification calculation is often to perform at manual calculation level separately from RTP system. Characteristics of output factors included in this calculation were explained on the basis of the situation in the world.
View Article and Find Full Text PDFThe purpose of this study was to determine whether or not salivary gland dysfunction occurs within the first three months after brachytherapy in patients with head and neck carcinoma. Of the 20 patients with head and neck squamous cell carcinoma included in this study, 11 were treated with brachytherapy and the remaining 9 patients received external irradiation. All the patients underwent a salivary gland scintigraphy before and after radiotherapy.
View Article and Find Full Text PDF