In humans, uric acid is an end-product of purine metabolism. Urate excretion from the human kidney is tightly regulated by reabsorption and secretion. At least eleven genes have been identified as human renal urate transporters.
View Article and Find Full Text PDF: Despite the encouragement of early initiation and titration of guideline-directed medical therapy (GDMT) for the treatment of heart failure (HF), most patients do not receive an adequate type and dose of pharmacotherapy in the real world. : This study aimed to determine the efficacy of titrating composite GDMT in patients with HF with reduced and mildly reduced ejection fraction and to identify patient conditions that may benefit from titration of GDMT. : This was a two-center, retrospective study of consecutive patients hospitalized with acute decompensated heart failure (ADHF).
View Article and Find Full Text PDFIn humans, uric acid is an end-product of purine metabolism. Urate excretion from the human kidney is tightly regulated by reabsorption and secretion. At least eleven genes have been identified as human renal urate transporters.
View Article and Find Full Text PDFBackground: Transcatheter aortic valve replacement (TAVR)-related coronary artery obstruction prediction remains unsatisfactory despite high mortality and novel preventive therapies.
Objectives: This study sought to develop a predictive model for TAVR-related coronary obstruction in native aortic stenosis.
Methods: Preprocedure computed tomography and fluoroscopy images of patients in whom TAVR caused coronary artery obstruction were collected.
Anastomotic complications of the coronary arteries were observed in approximately 5% of patients undergoing Bentall-type surgery. Given the high surgical risk of reoperation, percutaneous coronary intervention could be a treatment for anastomotic complications but is challenging because of the complicated anatomy after Bentall-type surgery. Here, a 70-year-old man underwent a Bentall operation during which the left main coronary artery was accidentally injured.
View Article and Find Full Text PDFBackground: Coronary obstruction is a rare but catastrophic complication of transcatheter aortic valve replacement (TAVR) and occurs mostly at the left coronary artery (LCA) ostium. However, some patients do not show any clinical findings, and thus, its detection is sometimes difficult. The peak diastolic flow velocity in left main coronary artery (LM) was reportedly increased in significant stenosis lesions.
View Article and Find Full Text PDFCardiovasc Interv Ther
October 2022
Prosthesis-patient mismatch (PPM), first described in 1978, occurs when a prosthetic valve functions normally, but has an effective orifice area that is too small relative to the patient's body surface area. It results in residual left ventricular afterload and higher transvalvular pressure gradient, which has been considered to impair prognosis. PPM following surgical aortic replacement is reportedly associated with worse clinical outcomes, such as high mortality.
View Article and Find Full Text PDFBackground: In transcatheter aortic valve replacement (TAVR) using SAPIEN 3 (S3) (Edwards Lifesciences, Irvine, CA, USA), some clinicians decrease or increase the delivery balloon volume (VOL) when deploying S3 or conducting post-dilatation. However, the effects of controlling VOL on transcatheter heart valve diameter (THVD) and valve function remain unclear. We assessed associations among VOL, THVD, and effective orifice area (EOA) of S3.
View Article and Find Full Text PDFBackground: The balloon-expandable SAPIEN 3 (S3) is superior to the older-generation balloon-expandable SAPIEN XT (XT) in a lower incidence of paravalvular aortic regurgitation, lower complication rates and better survival in transcatheter aortic valve implantation (TAVI). However, prosthesis-patient mismatch (PPM) more frequently occurs in S3 than XT. Further, little information is available on PPM after TAVI using S3 in Asians.
View Article and Find Full Text PDFObjectives: Patients' backgrounds and clinical outcomes in urgent/emergent/salvage transcatheter aortic valve replacement (Em-TAVR) remain unclear. We investigated patient characteristics and the mortality in Em-TAVR and the predictors for the need for Em-TAVR.
Methods: We consecutively enrolled 1613 patients undergoing TAVR for severe aortic stenosis between October 2013 and July 2016 from the Optimised transCathEter vAlvular interventioN (OCEAN)-transcatheter aortic valve implantation (TAVI) registry.
JACC Cardiovasc Interv
July 2020
Objectives: The aim of this study was to investigate the incidence, characteristics, hemodynamic conditions, and clinical significance of right-to-left (R-L) shunt through an iatrogenic atrial septal defect (iASD) after the MitraClip procedure.
Background: R-L shunt through an iASD after the MitraClip procedure has not been well investigated.
Methods: From 2014 to 2017, 385 consecutive patients with mitral regurgitation underwent the MitraClip procedure.
Background: Limited research has been conducted on the surgical management of the aortic valve in congenitally corrected transposition of great arteries (ccTGA) and to our knowledge there have been no reports on the treatment of bicuspid aortic regurgitation (AR) in ccTGA. We report on a ccTGA patient with bicuspid AR and systemic right ventricule (SRV) dysfunction who underwent transcatheter aortic valve replacement (TAVR).
Case Summary: A 17-year-old male with a history of ccTGA and cerebral palsy diagnosed at birth presented with heart failure.
Objectives: Little information is available on computed tomography (CT)-based predictors of stroke related to transcatheter aortic valve replacement (TAVR). The objective of this study was to determine whether anatomical features of the aortic valve and aorta visualized by CT are predictive parameters of stroke.
Methods: The study included 1270 patients who underwent preprocedural contrast-enhanced CT assessment and TAVR for severe aortic valve stenosis.
Objectives: The aim of this study was to report the 1-year results of transcatheter aortic valve replacement (TAVR) with the Edwards SAPIEN 3 (S3) valve in extremely large annuli.
Background: Favorable 30-day outcomes of S3 TAVR in annuli >683 mm have previously been reported. Pacemaker implantation rates were acceptable, and a larger left ventricular outflow tract and more eccentric annular anatomy were associated with increasing paravalvular leak.