Autonomic dysfunction in diabetes is serious but often underestimated. The purpose of this study was to evaluate hemodynamics within the important initial phase just after standing, which cannot be evaluated by conventional instruments for orthostatic hypotension. Earlobe blood flow (EBF), which indirectly reflects the blood pressure response on standing, was evaluated using a mini laser Doppler flowmeter during standing from the sitting position in 58 healthy controls and 56 diabetic patients categorized as without (11), mild (27), and advanced diabetic polyneuropathy (18).
View Article and Find Full Text PDFPurpose: Cephalic hemodynamic assessment is important in initial orthostatic hypotension. We sought to investigate cephalic blood flow (CBF) in the earlobe using a mini laser Doppler flowmeter (LDF) during orthostatic challenge. In addition, we clarified hemodynamic differences during a new active standing protocol using a footstool standing test (FST) with bending of the legs on the footstool in the sitting position to reduce the load of the squatting posture in the conventional squat standing test (SST).
View Article and Find Full Text PDFIEEE Trans Biomed Eng
August 2010
The authors propose a new sensor structure for an integrated laser Doppler blood flowmeter that consists of two silicon cavities with a PD and laser diode inside each cavity. A silicon lid formed with a converging microlens completes the package. This structure, which was achieved using micromachining techniques, features reduced optical power loss in the sensor, resulting in its small size and significantly low power consumption.
View Article and Find Full Text PDF