Publications by authors named "Masahiro Hirota"

To discharge waste liquid containing radioactive iodine into sewage systems, long-term storage or dilution with a large amount of water may be required until the radioactivity concentration reduces below the standard value. Processing the waste liquid could be easier if radioactive iodine could be separated from the water. This study verified the effectiveness of superabsorbent polymer and α-cyclodextrin as treatment agents to separate radioactive iodine from waste liquids.

View Article and Find Full Text PDF

Radiocesium released by the Fukushima Dai-ichi Nuclear Power Plant (FDNPP) accident still exists in the environment in two forms: adsorbed species on mineral particles in the soil and microparticles containing radiocesium mainly composed of silicate glass (CsMPs). CsMPs are dispersed not only around the FDNPP but also over a wide area of the Kanto region. The behavior and characteristics of CsMPs must be investigated to evaluate the impact of the FDNPP accident.

View Article and Find Full Text PDF

Alpha-cyclodextrin, a six D-glucose cyclic oligosaccharide, has several applications in food and pharmaceuticals, but has also been reported to retain iodine in a stable manner for 16 months. Radioactive iodine, which may cause thyroid cancer and hypofunction, must be properly managed. If the absorption of radioactive iodine is suppressed, it can be expected to lead to a reduction in thyroid exposure.

View Article and Find Full Text PDF

The effect of temperature and shielding on the lower detection limit of a thyroid I monitoring system was investigated in an anthropomorphic thyroid-neck phantom fitted with an imaging plate. The phantom was loaded with an I aqueous solution and monitored with the imaging plate for 10 min. After exposure, the plates were incubated with or without the shield at 0, 10, 20, 25, 30, or 40°C.

View Article and Find Full Text PDF

In direct organ measurements, there can be uncertainty to the quantified amount of activity due to variations in detector locations. Here, the authors demonstrate a new use of an imaging plate (IP) for evaluating this uncertainty. The method requires only that an array of regions of interest (ROIs) is set on a latent image obtained from the IP; each ROI conforms to an active area of the detector to be used.

View Article and Find Full Text PDF

An imaging plate (IP) system was used as an effective detector for direct measurement of radioactive surface contamination. The IP system displayed images designating the locations and extent of fixed surface contamination of uranyl acetate. The amount of radioactive waste produced during decontamination was reduced because the contaminated spots could be isolated; furthermore, creation of radioactive dust during removal of contamination was prevented because the contaminated spots could be removed without being pulverized.

View Article and Find Full Text PDF

In the spring of 2012, a year after the Fukushima Daiichi nuclear disaster, radiocesium-contaminated Japanese cedar pollen may have caused internal exposure to the general population by inhalation. To determine if pollen had been contaminated through uptake of radiocesium by Japanese cedars and was therefore contributing to inhalation doses, the authors measured radiocesium and Japanese cedar pollen adhered to masks worn by 68 human subjects residing in eastern Japan, including Fukushima prefecture, for 8 wk in the spring of 2012. The maximum cumulative Cs and Cs radioactivities on masks worn by an individual were 21 ± 0.

View Article and Find Full Text PDF

The distribution of radiocesium was examined in bamboo shoots, Phyllostachys pubescens, collected from 10 sites located some 41 to 1140 km from the Fukushima Daiichi nuclear power plant, Japan, in the Spring of 2012, 1 year after the Fukushima nuclear accident. Maximum activity concentrations for radiocesium ¹³⁴Cs and ¹³⁷Cs in the edible bamboo shoot parts, 41 km away from the Fukushima Daiichi plant, were in excess of 15.3 and 21.

View Article and Find Full Text PDF

The reductive effect of an anti-pollinosis mask against internal exposure from radioactive materials dispersed following the Fukushima Daiichi Nuclear Disaster was investigated. A single mask was worn continuously for 18 h from 15:00 JST on 15 March to 09:00 JST on 16 March 2011 at the Hongo campus of the University of Tokyo, Japan. An adult without a mask was exposed during this time to radiation of 6.

View Article and Find Full Text PDF

Rainwater was contaminated by a large release of radionuclides into the environment during the Fukushima Daiichi nuclear disaster. It became a matter of concern for Japan when several water purification plants detected ¹³¹I contamination in the drinking water. In the present study, the decontamination efficiency of two easily obtainable commercial water purifiers were examined for rainwater contaminated with ¹³¹I, ¹³⁴Cs and ¹³⁷Cs.

View Article and Find Full Text PDF
Article Synopsis
  • The study analyzed bamboos for radionuclide contamination due to the Fukushima nuclear accident across six locations ranging from 25 to 980 km from the plant.
  • Maximum levels of radiocesium (134)Cs and (137)Cs were significantly elevated in Fukushima city, while lower levels were detected in Kashiwa city and much lower or undetectable amounts were found in Toyohashi city, 440 km away.
  • The research found higher radiocesium activity concentrated in mature and fallen leaves compared to younger leaves, branches, and culms of the bamboo.
View Article and Find Full Text PDF

Neutron-induced reaction rate depth profiles inside concrete shield irradiated by intermediate energy neutron were calculated using a Monte-Carlo code and compared with an experiment. An irradiation field of intermediate neutron produced in the forward direction from a thick (stopping length) target bombarded by 400 MeV nucleon(-1) carbon ions was arranged at the heavy ion medical accelerator in Chiba. Ordinary concrete shield of 90 cm thickness was installed 50 cm downstream the iron target.

View Article and Find Full Text PDF

An in vivo measurement system using an imaging plate (IP) system was developed, which displayed images reflecting (239)Pu distribution in the lung of a phantom. The detection limits of the IP system for 1-12h exposures were between 1670 and 245 Bq at a 1.6 cm chest wall thickness.

View Article and Find Full Text PDF

Radioactive materials (sources) are managed by bookkeeping and stocktaking. The radiation protection section staffs should check the sources manually. Annual effective dose concerning stocktaking of them are estimated at some mSv concerning fingers.

View Article and Find Full Text PDF

Objective: This study demonstrates images obtained by (90)Y bremsstrahlung emission computed tomography (BECT), and characterizes the system performance of gamma cameras.

Methods: (90)Y BECT images of phantoms were acquired using a gamma camera equipped with a medium energy general purpose parallel-hole collimator. Three energy window widths of 50% (57-94 keV) centered at 75 keV, 30% (102-138 keV) at 120 keV, and 50% (139-232 keV) at 185 keV were set on a (90)Y bremsstrahlung spectrum.

View Article and Find Full Text PDF

A system for taking static thyroid (99m)Tc images was devised by using multiple imaging plates (IPs) and a low-energy high resolution collimator. System spatial resolution of the IP systems and the gamma camera was determined by referring to standards set by the National Electrical Manufacturers Association. Sensitivity was represented by using lower detection limits (LDLs).

View Article and Find Full Text PDF

A new 241Am lung monitoring system without shielding was devised by using an imaging plate system. The Lawrence Livermore National Laboratory's realistic torso phantom containing a 241Am lung was covered by imaging plates sealed in lightproof bags. The imaging plate system displayed 241Am lung images characteristic of the lung shape of the torso phantom.

View Article and Find Full Text PDF

High frequency electromagnetic fields in the 120 kHz band emitted from card readers for access control systems in radiation control areas cause abnormally high and erroneous indicated dose readings on semiconductor-type electronic personal dosimeters (SEPDs). All SEPDs malfunctioned but recovered their normal performance by resetting after the exposure ceased. The minimum distances required to prevent electromagnetic interference varied from 5.

View Article and Find Full Text PDF

The effects of neck diameter, thyroid volume, and prethyroid tissue thickness on a count-activity conversion coefficient and the detection limit of a thyroid 131I monitoring system with an imaging plate (IP) were estimated by using an anthropomorphic thyroid-neck phantom. The conversion coefficient and detection limit of the IP system was approximately constant for normal Japanese adults regardless of their neck diameters, thyroid volumes, and prethyroid tissue thicknesses. The IP system is a new option for thyroid 131I monitoring.

View Article and Find Full Text PDF