Damage thresholds and structures on a metal aluminum and an aluminum oxide crystal induced by the soft x-ray free electron laser irradiations were evaluated. Distinctive differences in damage thresholds and structures were observed for these materials. On the aluminum oxide crystal surface, in particular, a novel, to the best of our knowledge, surface processing, which we suggest defining as "peeling," was recognized.
View Article and Find Full Text PDFHere we demonstrate the results of investigating the damage threshold of a LiF crystal after irradiating it with a sequence of coherent femtosecond pulses using the European X-ray Free Electron Laser (EuXFEL). The laser fluxes on the crystal surface varied in the range ∼ 0.015-13 kJ/cm per pulse when irradiated with a sequence of 1-100 pulses (t ∼ 20 fs, E = 9 keV).
View Article and Find Full Text PDFA counter-propagating laser-beam platform using a spherical plasma mirror was developed for the kilojoule-class petawatt LFEX laser. The temporal and spatial overlaps of the incoming and redirected beams were measured with an optical interferometer and an x-ray pinhole camera. The plasma mirror performance was evaluated by measuring fast electrons, ions, and neutrons generated in the counter-propagating laser interaction with a Cu-doped deuterated film on both sides.
View Article and Find Full Text PDFAlthough laser irradiation with femtosecond pulses is known to generate crystallization and morphological changes, the contribution of optical parameters to material changes is still in discussion. Here, we compare two structures irradiated near Si-L2,3 edges by an extreme ultraviolet femtosecond pulse. Our result implies that, despite the femtosecond irradiation regime, these values of the optical attenuation length between the wavelengths of 10.
View Article and Find Full Text PDFThis paper reports on the absolute response of a Fuji BAS-TR image plate to relatively low-energy protons (<0.2 MeV) and carbon ions (<1 MeV) accelerated by a 10-TW-class compact high-intensity laser system. A Thomson parabola spectrometer was used to discriminate between different ion species while dispersing the ions according to their kinetic energy.
View Article and Find Full Text PDFThere is no evaluation method currently available to assess intraoperative pedicle screw fixation (PSF) strength. In this study, we established a laser-based resonance frequency analysis (RFA) system with high-speed, noncontact, quantitative measurements of PSF. Clinical investigations in the future can assess surgical failure risk of implants.
View Article and Find Full Text PDFWe investigated the charge-separated spectra of highly charged suprathermal bismuth (Bi) ions from a dual laser-produced plasma soft x-ray source developed for soft x-ray microscopy. The charge distribution of these suprathermal ions emitted from a solid planar Bi target was measured by an electrostatic energy analyzer. The maximum ionic charge state was observed to be Z = 17 and to possess a maximum energy of about 200 keV.
View Article and Find Full Text PDFThis article reports the development of a compact Thomson parabola spectrometer for laser-accelerated ions that can measure angular distribution with a high energy resolution and has a variable measurable energy range. The angular-resolved energy spectra for different ion species can be measured in a single shot, and the sampling angle can be selected from outside the vacuum region. The electric and magnetic fields are applied to the ion dispersion by using a permanent magnetic circuit and annulus sector-shaped electrodes with a wedge configuration.
View Article and Find Full Text PDFWe demonstrate sub-micrometer processing of two kinds of thin films, polymethyl methacrylate (PMMA) and metal nano-particle resist, by focusing high-order harmonics of near-IR femtosecond laser pulses in the extreme ultraviolet (XUV) wavelength region (27.2-34.3 nm) on the thin film samples using an ellipsoidal focusing mirror.
View Article and Find Full Text PDFWe have developed a soft x-ray laser (SXRL) beamline equipped with an intensity monitor dedicated to ablation study such as surface processing and damage formation. The SXRL beam having a wavelength of 13.9 nm, pulse width of 7 ps, and pulse energy of around 200 nJ is generated from Ag plasma mediums using an oscillator-amplifier configuration.
View Article and Find Full Text PDFLaser-induced damage thresholds (LIDTs) of silica glasses obtained by the femtosecond soft x-ray free-electron laser (SXFEL, 13.5 nm, 70 fs) and the picosecond soft x-ray laser (SXRL, 13.9 nm, 7 ps) are evaluated.
View Article and Find Full Text PDFArtificial joint acetabular cup stability is essential for successful total hip arthroplasty. However, a quantitative evaluation approach for clinical use is lacking. We developed a resonance frequency analysis (RFA) system involving a laser system that is fully contactless.
View Article and Find Full Text PDFTo generate bright water-window (WW) soft x rays (2.3-4.4 nm), gold slab targets were irradiated with laser pulses (1064 nm, 7 ns, 1 J).
View Article and Find Full Text PDFWe demonstrate intense emission in the water-window soft x-ray spectral region by controlling the spectral behavior through changing the balance between emissivity and self-absorption in an expanding plasma. The number of photons obtained from a dual laser irradiated target with a 150-ps pre-pulse was maximized at 3.8 × 10 photons/sr in λ = 2.
View Article and Find Full Text PDFThe effect of optical thickness in a bismuth water-window soft x-ray source is considered by comparing the emission from laser-produced plasmas of a 7.5% atomic density foam target and a solid-density target. The number of photons recorded in the 4 nm region was comparable for both targets at a plasma-initiating laser pulse duration of 6 ns.
View Article and Find Full Text PDFA flat-field grazing incidence spectrometer operating on the spectral region from 1 to 10 nm was built for research on physics of high temperature and high energy density plasmas. It consists of a flat-field grating with 2400 lines/mm as a dispersing element and an x-ray charged coupled device (CCD) camera as the detector. The diffraction efficiency of the grating and the sensitivity of the CCD camera were directly measured by use of synchrotron radiation at the BL-11D beamline of the Photon Factory (PF).
View Article and Find Full Text PDFWhile it has been expected that X-ray laser will be widely applied to biomedical studies, this has not been achieved to date and its biological effects such as DNA damage have not been evaluated. As a first step for its biological application, we developed a culture cell irradiation system, particularly designed for a plasma-driven soft X-ray laser pulse, to investigate whether the soft X-ray laser is able to induce DNA double strand breaks (DSBs) in living cells or not. The human adenocarcimona cell line A549 was irradiated with the soft X-ray laser at a photon energy of 89 eV and the repair focus formation of the DSBs was assessed by immunofluorescence staining with antiphosphorylated DNA-PKcs (p-DNA-PKcs), ATM (p-ATM) and γ-H2AX antibody.
View Article and Find Full Text PDFThe advent of X-ray lasers allowed the realization of compact coherent soft X-ray sources, thus opening the way to a wide range of applications. Here we report the observation of unexpected concentric rings in the far-field beam profile at the output of a two-stage plasma-based X-ray laser, which can be considered as the first manifestation of a mirage phenomenon in X-rays. We have developed a method of solving the Maxwell-Bloch equations for this problem, and find that the experimentally observed phenomenon is due to the emergence of X-ray mirages in the plasma amplifier, appearing as phase-matched coherent virtual point sources.
View Article and Find Full Text PDFPump and probe reflective imaging using a soft x-ray laser probe was applied to the observation of the early stage of femtosecond laser ablation process on platinum. In strongly excited area, drastic and fast reflectivity drop was observed. In moderately excited area, the decay of the reflectivity is slower than that in the strongly excited area, and the reflectivity reaches its minimum at t = 160 ps.
View Article and Find Full Text PDFThe usefulness of laser plasma X-ray pulses for medical and radiation biological studies was investigated, and the effects of laser plasma X rays were compared with those of conventional sources such as a linear accelerator. A cell irradiation system was developed that used copper-Kα (8 keV) lines from an ultrashort high-intensity laser to produce plasma. The absorbed dose of the 8 keV laser plasma X-ray pulse was estimated accurately with Gafchromic® EBT film.
View Article and Find Full Text PDFA dedicated radiation biology x-ray generation and exposure system has been developed. 8.0 keV in energy x-ray pulses generated with a femtosecond-laser pulse was used to irradiate sample cells through a custom-made culture dish with a silicon nitride membrane.
View Article and Find Full Text PDFA highly coherent 13.9 nm x-ray laser (XRL) is generated under an oscillator-amplifier configuration using a new tape target system and a driver laser system with a 0.1 Hz repetition rate.
View Article and Find Full Text PDFA molybdenum slab target was irradiated by double pulses of a line-focused chirped-pulse-amplification Nd:glass laser. A probe beam was injected in the plasma in the longitudinal direction, and we found that the probe beam was guided in the plasma with the plasma length of up to 4.3 mm at the time of 0.
View Article and Find Full Text PDF