Background: Guidewire retention and sharps injury during central venous catheter insertion are errors that cause patient and healthcare professional harm. The WireSafe is a novel procedure safety pack engineered to prevent guidewire retention and sharps injury during central venous catheter insertion. This is a pilot study aimed to determine its acceptability, usability and safety during clinical practice.

View Article and Find Full Text PDF

Background: Using a dextrose-containing solution, instead of normal saline, to maintain the patency of an arterial cannula results in the admixture of glucose in line samples. This can misguide the clinician down an inappropriate treatment pathway for hyperglycaemia.

Methods: Following a near-miss and subsequent educational and training efforts at our institution, we conducted two simulations: (1) to observe whether 20 staff would identify a 5% dextrose/0.

View Article and Find Full Text PDF

Objectives: Guidewire retention during central venous catheter (CVC) insertion is considered a "never event." We analyzed the National Health Service England Never Event database (2004-2015) to explore the process of guidewire retention and identify potential preventative measures.

Methods: We performed a systematic analysis of reported retained guidewire incidents by 3 independent reviewers.

View Article and Find Full Text PDF

Background: Central venous catheter guidewire retention is classed as a 'never event' in the United Kingdom, with the potential for significant patient harm. If the retained guidewire remains within the central venous catheter lumen, bedside techniques may facilitate guidewire retrieval. However, these techniques may be ineffective if the guidewire has already passed below skin level.

View Article and Find Full Text PDF

Background: Endotracheal tube cuff pressures should be maintained between 20 and 30 cm H O to prevent the aspiration of subglottic secretions past the cuff. Guidance recommends regular monitoring of the cuff pressure, performed using a handheld manometer/inflator. Poor technique can lead to transient deflation of the cuff, leading to the bolus aspiration of upper respiratory tract secretions, tracheal colonization and, ultimately, ventilator-associated pneumonia.

View Article and Find Full Text PDF

Purpose: The inadvertent, simultaneous use of heat and moisture exchangers (HMEs) and heated humidifiers (HHs) can result in waterlogging of the filter and sudden ventilation tube occlusion, with potentially fatal consequences. Following an NHS England Safety Alert, a near miss and educational reminders in our institution, we introduced new guidelines to solely use HHs in the intensive care unit and HMEs only for patient transfers. No further incidents have occurred, however this solution is potentially fallible.

View Article and Find Full Text PDF

Background: Retained central venous catheter guidewires are never events. Currently, preventative techniques rely on clinicians remembering to remove the guidewire. However, solutions solely relying upon humans to prevent error inevitably fail.

View Article and Find Full Text PDF

Background: Aspiration of subglottic secretions past the endotracheal tube (ETT) cuff is a prerequisite for developing ventilator-associated pneumonia (VAP). Subglottic secretion drainage (SSD) ETTs reduce aspiration of subglottic secretions and have demonstrated lower VAP rates. We compared the performance of seven SSD ETTs against a non-SSD ETT in preventing aspiration below inflated cuffs.

View Article and Find Full Text PDF

Purpose: Hypoxia is one of the leading causes of anesthesia-related injury. In response to the limitations of conventional preoxygenation, Transnasal Humidified Rapid-Insufflation Ventilatory Exchange (THRIVE) has been used as a method of providing both preoxygenation and apneic oxygenation during intubation.

Materials And Methods: In this prospective, observational study, THRIVE was introduced in a critical care unit (CCU), operating room (OR), and emergency department (ED) during emergency intubation of patients at high risk of hypoxia.

View Article and Find Full Text PDF

Leaving drug trolleys unlocked and unattended during drug rounds creates opportunities for drug theft and tampering. A new device was developed by our trust to detect when an open drug trolley is left unattended; it then sounds an alarm to remind staff to return to the trolley. This article describes use of the alarm on general hospital wards in one trust in the east of England.

View Article and Find Full Text PDF

Catheter-related blood stream infections (CR-BSI) account for 30% of healthcare acquired infection (HAI). Colonization of connector hubs and contaminated syringes are thought to increase the risk of CR-BSI. The Coated Antiseptic Tip (CAT) syringe was developed to decontaminate connector hubs, thereby reducing the risk of CR-BSI.

View Article and Find Full Text PDF

Purpose: Heat and moisture exchangers (HMEs) and heated humidifiers (HHs) may be used together inadvertently. Such an incident occurred at our institution resulting in airway occlusion.

Material And Methods: A bench-top study was conducted to compare the incidence of airway occlusion when using (1) no airway humidification, (2) HME alone, (3) HH alone, and (4) both HME and HH in combination as part of a standard breathing circuit.

View Article and Find Full Text PDF

A controlled trial of once daily cleaning of computer keyboards in an intensive care unit was performed comparing 2% chlorhexidine gluconate-70% isopropyl alcohol (CHG) and a chlorine dioxide-based product used as a standard in our hospital. A study before and after the introduction of once daily keyboard cleaning with CHG in the wider hospital was also completed. Cleaning with CHG showed a sustained and significant reduction in bacterial colony forming units compared with the chlorine dioxide-based product, demonstrating its unique advantage of maintaining continuous keyboard cleanliness over time.

View Article and Find Full Text PDF