Volumetric absorptive microsampling (VAMS) is increasingly proposed as a clinically reliable therapeutic drug monitoring (TDM) sampling methodology. The study aimed to establish the reliability and real-life feasibility of patient self-collected capillary VAMS for TDM of antiseizure medication (ASMs), using plasma ASMs concentrations from venous blood as a reference standard. Nurses collected venous and capillary blood samples using VAMS.