Objectives: This study sought to elucidate the diagnostic performance of 0.55 T magnetic resonance imaging (MRI) for pediatric dental imaging, specifically in terms of the image quality (IQ) for detecting ectopic and/or supernumerary teeth, compared with routine ultra-low-dose computed tomography (ULD-CT) of the jaw.
Materials And Methods: A total of 16 pediatric patients (mean age: 12.
Objectives: To compare a novel, non-contrast, flow-independent, 3D isotropic magnetic resonance angiography (MRA) sequence that combines respiration compensation, electrocardiogram (ECG)-triggering, undersampling, and Dixon water-fat separation with an ECG-triggered aortic high-pitch computed tomography angiography (CTA) of the aorta.
Materials And Methods: Twenty-five patients with recent CTA were scheduled for non-contrast MRA on a 3 T MRI. Aortic diameters and cross-sectional areas were measured on MRA and CTA using semiautomatic measurement tools at 11 aortic levels.
Objectives: This study evaluates the impact of a scanner-integrated, customized clinical decision support system (CDSS) on the acquisition technique, scan range, and reconstruction in thoracoabdominal CT.
Materials And Methods: We applied CDSS in contrast-enhanced examinations of the trunk with various clinical indications on a recent scanner with the capability of dual-energy CT (DECT), anatomic landmark detection (ALD), and iterative metal-artifact reduction (MAR). Simple and comprehensive questions about the patient's breath hold capability, the anatomical region of interest, and metal implants can be answered after the localizer.
(1) Purpose: to compare right ventricular (RV) functional parameters in children with surgically repaired congenital heart disease (CHD) using single/double breath hold (BH) and free-breathing (FB) real-time compressed sensing (CS) cine cardiac magnetic resonance (cMRI) with standard retrospective segmented multi breath hold (RMB) cine cMRI. (2) Methods: Twenty patients with CHD underwent BH and FB, as well as RMB cine cMRI, at 3T to obtain a stack of continuous axial images of the RV. Two radiologists independently performed qualitative analysis of the image quality (rated on a 5-point scale; 1 = non-diagnostic to 5 = excellent) and quantitative analysis of the RV volume measurements.
View Article and Find Full Text PDFObjectives: To investigate the efficacy of an in-line non-rigid motion-compensated reconstruction (NRC) in an image-navigated high-resolution three-dimensional late gadolinium enhancement (LGE) sequence with Dixon water-fat separation, in a clinical setting.
Methods: Forty-seven consecutive patients were enrolled prospectively and examined with 1.5 T MRI.
Objectives: To evaluate an image-navigated isotropic high-resolution 3D late gadolinium enhancement (LGE) prototype sequence with compressed sensing and Dixon water-fat separation in a clinical routine setting.
Material And Methods: Forty consecutive patients scheduled for cardiac MRI were enrolled prospectively and examined with 1.5 T MRI.
Background: This study sought to retrospectively evaluate the clinical and magnetic resonance imaging (MRI) outcomes of u-HA/PLLA pin (u-HA/PLLA: hydroxyapatite/poly-L-lactic acid) pin fixation of unstable osteochondritis dissecans (OCD) lesions of the knee.
Methods: Seven adolescent patients (four females and three males) with arthroscopically unstable OCD lesions of the knee were included. The mean age at diagnosis was 13.
Background: Conventional 2D inversion recovery (IR) and phase sensitive inversion recovery (PSIR) late gadolinium enhancement (LGE) cardiovascular magnetic resonance (CMR) have been widely incorporated into routine CMR for the assessment of myocardial viability. However, reliable suppression of fat signal, and increased isotropic spatial resolution and volumetric coverage within a clinically feasible scan time remain a challenge. In order to address these challenges, this work proposes a highly efficient respiratory motion-corrected 3D whole-heart water/fat LGE imaging framework.
View Article and Find Full Text PDFBackground: Radiation dose at CT should be as low as possible without compromising diagnostic quality.
Objective: To assess the potential for maximum dose reduction of pediatric lung dual-source CT with spectral shaping and advanced iterative reconstruction (ADMIRE).
Materials And Methods: We retrospectively analyzed dual-source CT acquisitions in a full-dose group (FD: 100 kV, 64 reference mAs) and in three groups with spectral shaping and differing reference mAs values (Sn: 100 kV, 96/64/32 reference mAs), each group consisting of 16 patients (age mean 11.
Food standards and quality control are important means to ensure public health. In the last decade, melamine has become a rather notorious example of food adulteration: Spiking products with low-cost melamine in order to feign high amino acid content exploits the lack in specificity of the established Kjeldahl method for determining organic nitrogen. This work discusses the responses of a sensor based on quartz crystal microbalances (QCM) coated with molecularly imprinted polymers (MIP) to detect melamine in real life matrices both in a selective and a sensitive manner.
View Article and Find Full Text PDFBackground: Peripherally inserted central catheters (PICCs) provide secure intravenous access for the delivery of life-sustaining medications and nutrition. They are commonly used in pediatrics. Confirmation of correct central catheter tip position is crucial.
View Article and Find Full Text PDFObjective: The apparent diffusion coefficient (ADC) is increasingly used as a quantitative biomarker in oncological imaging. ADC calculation is based on raw diffusion-weighted imaging (DWI) data, and multiple post-processing methods (PPMs) have been proposed for this purpose. We investigated whether PPM has an impact on final ADC values.
View Article and Find Full Text PDFDiagnostic imaging of head and neck cancer has made enormous progress during recent years. Next to morphological imaging modalities (computed tomography [CT] and magnetic resonance imaging [MRI]), there are also hybrid imaging systems that combine functional and morphological information (positron emission tomography [PET]/CT and PET/MRI). The aim of this study was to compare the diagnostic accuracy of PET/MRI in the diagnosis of head and neck cancer with other imaging modalities (MRI, CT, PET/CT).
View Article and Find Full Text PDFObjectives: Integrated whole-body positron emission tomography (PET)/magnetic resonance (MR) scanners have recently been introduced and potentially offer new possibilities in hybrid imaging of oncologic patients. Integration of PET in a whole-body MR system requires new PET detector technology and new approaches to attenuation correction of PET data based on MR imaging. The aim of this study was to evaluate the clinical performance and image quality parameters of integrated whole-body PET/MR hybrid imaging in intraindividual comparison with PET/CT in oncologic patients.
View Article and Find Full Text PDF